Filters
  • Manufacturer
    • TE Connectivity
    • Molex
    • Panduit
    • 3M
    • Lapp
    • NTE ELECT
    • Keystone Electronics Corp
    • Greenlee Klauke
    • Phoenix Contact
    • Wurth Electronics
    • AMP
    • JST
    • Master Appliance
    • Remington
    • Brady Corporation
    • HEYCO PRODUCTS
    • interlight
    • Littelfuse
    • Weidmuller
    • Texas Instruments
    • Harwin
    • RS Pro
    • ABB
    • Adafruit
    • Greenlee
    • Desco
    • Raychem
    • Amphenol
    • Eaton
    • Cooper Bussmann
    • Multicomp
    • Wiha
    • Advanced
    • Schneider
    • EAO
    • Honeywell
    • SMC Corporation
    • SparkFun
    • C&K
    • Cooper
    • Finder
    • FLUKE
    • FLUKE Pomona
    • HellermannTyton
    • National Semiconductor
    • Norgren
    • Ohmite
    • Panasonic
    • Rockwell
    • Schurter
    • SK Hand Tool
    • STMicroelectronics
    • Elesa USA Corporation
    • Abracon
    • Alpha and Omega
    • Altech
    • Apex Tool Group
    • Astro Tool
    • Belden
    • Cypress
    • EMC
    • Fairchild
    • Glenair
    • Klein Tools
    • Lantronix
    • Lumberg Automation
    • Menda
    • Mitutoyo
    • Murata
    • Omron
    • PIC GmbH
    • Radiall
    • SICK
    • Visual
    • Wakefield
    • WECO
  • Gender
  • Insulation
  • RoHS Status
  • Termination
  • Width - Tab
  • Tab Thickness
  • Factory Lead Time
  • Packaging
  • Part Status
  • Length
  • Mount
  • Contact Materials

Attribute column

Categories

Terminals - Quick Connects, Quick Disconnect Connectors

View Mode:
5946 Results

Product

Inventory

Pricing(USD)

Quantity

Datasheet

RoHS

Factory Lead Time

Contact Plating

Mount

Mounting Type

Package / Case

Material

Weight

Body Material

Contact Materials

Insulation Materials

Packaging

Published

Series

Pbfree Code

Part Status

Moisture Sensitivity Level (MSL)

Termination

ECCN Code

Connector Type

Number of Positions

Max Operating Temperature

Min Operating Temperature

Color

Gender

HTS Code

Voltage - Rated DC

Orientation

Depth

Current Rating

Contact Finish

Voltage - Rated AC

Approval Agency

Wire Gauge

ELV

Wire Gauge (Max)

Wire Gauge (Min)

Body Plating

Wire/Cable Gauge

Terminal and Terminal Block Type

Insulation Diameter

Insulation

Terminal Type

Wire Cross Section

Length - Tab

Features

Diameter

Length

Width

Length - Overall

Diameter - Inside

Tab Thickness

Width - Tab

Material Thickness

Radiation Hardening

REACH SVHC

RoHS Status

Lead Free

8282
8282

Keystone Electronics

26
Datasheet

6 Weeks

-

Free Hanging

Free Hanging (In-Line)

-

-

-

-

Copper

-

Bulk

-

-

-

Active

1 (Unlimited)

Crimp

EAR99

-

-

-

-

-

Male

8536.90.40.00

-

Straight

-

-

Tin

-

-

18-22 AWG

-

18 AWG

22 AWG

-

-

TAB TERMINAL

-

Non-Insulated

Standard

-

-

-

-

18.542mm

6.35mm

0.730 18.54mm

-

0.032 0.81mm

0.250 6.35mm

-

-

-

ROHS3 Compliant

Lead Free

DNF18-187FIB-C
DNF18-187FIB-C

Panduit Corp

100
Datasheet

4 Weeks

Tin

Free Hanging

Free Hanging (In-Line)

-

Nylon

81.646627g

-

Brass

-

Bulk

2009

Pan-Term®

-

Active

Not Applicable

Crimp

EAR99

-

-

-

-

Red

Female

8536.90.40.00

-

-

7.4mm

-

-

-

-

18-22 AWG

-

18 AWG

22 AWG

-

-

PUSH-ON TERMINAL

0.136 (3.45mm)

Fully Insulated

Standard

1.5 mm2

-

Serrated Termination

-

19.8mm

-

0.780 19.81mm

-

0.032 0.81mm

0.187 4.75mm

-

No

-

ROHS3 Compliant

-

4469
4469

Keystone Electronics

415
Datasheet

6 Weeks

-

Free Hanging

Free Hanging (In-Line)

-

-

-

-

Brass

-

Bulk

-

-

yes

Active

1 (Unlimited)

Crimp

EAR99

-

-

-

-

-

Female

8538.90.60.00

-

Straight

-

-

Tin

-

-

16-20 AWG

-

16 AWG

20 AWG

-

-

WIRE TERMINAL

-

Non-Insulated

Standard

-

-

-

-

16.256mm

-

0.640 16.26mm

-

0.020 0.51mm

0.205 5.21mm

-

-

-

ROHS3 Compliant

Lead Free

DNG18-187FB-3K
DNG18-187FB-3K

Panduit Corp

276000
-

4 Weeks

Tin

Free Hanging

Free Hanging (In-Line)

-

-

-

-

Brass

-

Tape & Reel (TR)

2006

ReelSmart™ Supra-Grip™

-

Active

Not Applicable

Crimp

EAR99

-

-

-

-

Red

Female

8536.90.40.00

-

-

7.4mm

-

-

-

-

18-22 AWG

-

22 AWG

18 AWG

-

-

WIRE TERMINAL

0.090 ~ 0.126 (2.29mm ~ 3.20mm)

Fully Insulated

Standard

1.5 mm2

-

Butted Seam

-

22.606mm

-

0.890 22.61mm

-

0.032 0.81mm

0.187 4.75mm

-

No

-

ROHS3 Compliant

-

DPF18-111FIB-M
DPF18-111FIB-M

Panduit Corp

In Stock

-

Datasheet

4 Weeks

Tin

Free Hanging

Free Hanging (In-Line)

-

-

-

-

Brass

Nylon

Bulk

2007

DiscoGrip™

-

Active

Not Applicable

Crimp

EAR99

-

-

-

-

Red

Female

8536.90.40.00

-

-

4.83mm

-

-

-

-

18-22 AWG

-

22 AWG

18 AWG

-

-

PUSH-ON TERMINAL

0.080 ~ 0.132 (2.03mm ~ 3.35mm)

Fully Insulated

Standard

-

-

-

-

18.034mm

4.83mm

0.710 18.03mm

-

0.020 0.51mm

0.110 2.79mm

-

No

-

ROHS3 Compliant

-

3240055
3240055

Phoenix Contact

189
Datasheet

4 Weeks

Tin

Free Hanging

Free Hanging (In-Line)

-

Brass

-

-

Brass

-

Bulk

2011

CLIPLINE

-

Active

1 (Unlimited)

Crimp

-

-

-

105°C

-20°C

Blue

Female

-

-

-

-

-

Tin

-

-

14-16 AWG

-

16 AWG

14 AWG

-

-

-

-

Non-Mating End Insulated

Standard

-

-

-

-

21.9964mm

6.3mm

0.866 22.00mm

-

0.032 0.81mm

0.250 6.35mm

-

-

-

RoHS Compliant

-

DNH14-250FIM-Q
DNH14-250FIM-Q

Panduit Corp

In Stock

-

-

4 Weeks

-

Free Hanging

Free Hanging (In-Line)

-

-

58.967008g

-

Brass

Nylon

Bulk

2005

Pan-Term®

-

Active

Not Applicable

Crimp

EAR99

-

-

-

-

Blue

Male

8536.90.40.00

-

-

10.4mm

-

Tin

-

-

14-16 AWG

-

16 AWG

14 AWG

Nickel

-

PUSH-ON TERMINAL

0.158 (4.01mm)

Fully Insulated Heat Shrink

Standard

-

-

-

-

38.1mm

10.4mm

1.500 38.10mm

-

0.032 0.81mm

0.250 6.35mm

-

No

-

ROHS3 Compliant

-

899
-

3 Weeks

Tin

Free Hanging

Free Hanging (In-Line)

-

-

1.372117kg

-

Brass

-

Bulk

2002

Scotchlok™

-

Active

1 (Unlimited)

Crimp

-

-

-

-

-

Blue

Female

-

-

-

-

-

-

-

-

14-16 AWG

-

16 AWG

14 AWG

-

-

-

0.145 (3.68mm)

Fully Insulated

Standard

-

-

-

-

23.114mm

-

0.910 23.11mm

-

0.032 0.81mm

0.250 6.35mm

-

-

-

RoHS Compliant

-

3240053
3240053

Phoenix Contact

In Stock
Datasheet

4 Weeks

-

Free Hanging

Free Hanging (In-Line)

-

-

-

-

Brass

-

Bulk

2011

CLIPLINE

-

Active

1 (Unlimited)

Crimp

EAR99

-

-

105°C

-20°C

Blue

Female

8536.90.40.00

-

-

-

-

Tin

-

-

14-16 AWG

-

16 AWG

14 AWG

-

-

PUSH-ON TERMINAL

-

Non-Mating End Insulated

Standard

2.5 mm2

-

-

-

19.9898mm

4.8mm

0.787 20.00mm

-

0.020 0.51mm

0.187 4.75mm

-

-

-

RoHS Compliant

-

DNFR14-250FIB-M
DNFR14-250FIB-M

Panduit Corp

99000
Datasheet

4 Weeks

Tin

Free Hanging

Free Hanging (In-Line), Right Angle

-

-

1.496855kg

-

Brass

Nylon

Bulk

2005

Pan-Term®

yes

Active

Not Applicable

Crimp

-

INTERCONNECTION DEVICE

-

-

-

Blue

Female

-

-

-

9.4mm

-

-

-

-

14-16 AWG

-

14 AWG

16 AWG

-

-

-

0.178 (4.52mm)

Fully Insulated

Angled - 90°, Flag

-

-

-

-

15.24mm

-

-

-

0.032 0.81mm

0.250 6.35mm

-

No

-

ROHS3 Compliant

-

DNFR14-205FIB-L
DNFR14-205FIB-L

Panduit Corp

50
-

4 Weeks

Tin

Free Hanging

Free Hanging (In-Line), Right Angle

-

-

81.646627g

-

Brass

Nylon

Bulk

2005

Pan-Term®

-

Active

Not Applicable

Crimp

EAR99

-

-

-

-

Blue

Female

8536.90.40.00

-

-

9.4mm

-

-

-

-

14-16 AWG

-

14 AWG

16 AWG

-

-

PUSH-ON TERMINAL

0.178 (4.52mm)

Fully Insulated

Angled - 90°, Flag

-

-

-

-

15.24mm

-

-

-

0.032 0.81mm

0.187 4.75mm 0.205 5.21mm

-

No

-

ROHS3 Compliant

-

DVF14-206-C
DVF14-206-C

Panduit Corp

In Stock

-

-

4 Weeks

Tin

Free Hanging

Free Hanging (In-Line)

-

-

-

Copper

Brass

Vinyl

Bulk

2005

Pan-Term®

-

Active

Not Applicable

Crimp

-

INTERCONNECTION DEVICE

-

-

-

Blue

Female

-

-

-

6.4mm

-

-

-

-

14-16 AWG

-

16 AWG

14 AWG

-

-

-

0.162 (4.11mm)

Non-Mating End Insulated

Standard

-

-

-

-

19.304mm

6.35mm

0.760 19.30mm

-

0.020 0.51mm

0.187 4.75mm 0.205 5.21mm

-

No

-

ROHS3 Compliant

-

DVF18-205-CY
DVF18-205-CY

Panduit Corp

In Stock

-

-

4 Weeks

Tin

Free Hanging

Free Hanging (In-Line)

-

-

-

Copper

Brass

-

Bulk

2005

Pan-Term®

-

Active

Not Applicable

Crimp

EAR99

-

-

-

-

Red

Female

8536.90.40.00

-

-

6.4mm

-

-

-

-

18-22 AWG

-

22 AWG

18 AWG

-

-

PUSH-ON TERMINAL

0.137 (3.48mm)

Non-Mating End Insulated

Standard

-

-

-

-

19.304mm

-

0.760 19.30mm

-

0.032 0.81mm

0.187 4.75mm 0.205 5.21mm

-

No

-

ROHS3 Compliant

-

8273
8273

Keystone Electronics

532
Datasheet

6 Weeks

-

Free Hanging

Free Hanging (In-Line)

-

-

-

-

Copper

-

Bulk

-

-

-

Active

1 (Unlimited)

Crimp

EAR99

-

-

-

-

-

Female

8536.90.40.00

-

Straight

-

-

Tin

-

-

18-22 AWG

-

18 AWG

22 AWG

-

-

PUSH-ON TERMINAL

-

Non-Insulated

Standard

-

-

-

-

16.764mm

6.35mm

0.660 16.76mm

-

0.032 0.81mm

0.250 6.35mm

-

-

-

ROHS3 Compliant

Lead Free

3572
3572

Keystone Electronics

1040
Datasheet

6 Weeks

Tin

Through Hole

Through Hole

-

-

-

-

Brass

-

Bulk

-

-

-

Active

1 (Unlimited)

Solder

EAR99

-

-

-

-

-

Female

7318.15.60.80

-

Right Angle

-

-

Tin Nickel

-

-

-

-

-

-

-

-

TAB TERMINAL

-

Non-Insulated

Horizontal

-

0.250 6.35mm

-

-

10.2mm

-

-

-

0.032 0.81mm

0.187 4.75mm

-

-

-

ROHS3 Compliant

-

1286
1286

Keystone Electronics

16174
Datasheet

6 Weeks

Tin

Through Hole, Vertical

Through Hole

-

-

-

-

Brass

-

Bulk

-

-

yes

Active

1 (Unlimited)

Solder

EAR99

-

1

-

-

-

Male

8535.90.80.60

-

Straight

6.35mm

-

-

-

UL

-

-

-

-

-

-

TAB TERMINAL

-

Non-Insulated

Standard

-

0.250 6.35mm

-

1.1684mm

12.7mm

-

0.500 12.70mm

1.78 mm

0.020 0.51mm

0.205 5.21mm

-

-

-

ROHS3 Compliant

Lead Free

DR10-250-D
DR10-250-D

Panduit Corp

17

-

-

4 Weeks

-

Free Hanging

Free Hanging (In-Line), Right Angle

-

-

997.903214g

-

Brass

-

Bulk

2001

Pan-Term®

-

Active

Not Applicable

Crimp

EAR99

-

-

-

-

Yellow

Female

8536.90.40.00

-

-

14.5mm

-

Tin

-

-

10-12 AWG

-

12 AWG

10 AWG

-

-

PUSH-ON TERMINAL

-

Non-Insulated

Angled - 90°, Flag

-

-

-

-

15.5mm

7.62mm

-

-

0.032 0.81mm

0.250 6.35mm

-

-

-

ROHS3 Compliant

-

DNG18-250FB-3K
DNG18-250FB-3K

Panduit Corp

30000
-

4 Weeks

-

Free Hanging

Free Hanging (In-Line)

Metal

-

-

-

Brass

-

Tape & Reel (TR)

2006

ReelSmart™ Supra-Grip™

yes

Active

Not Applicable

Crimp

EAR99

-

-

-

-

Red

Female

8536.90.40.00

-

-

8.9mm

-

Tin

-

-

18-22 AWG

-

22 AWG

18 AWG

-

-

WIRE TERMINAL

0.090 ~ 0.126 (2.29mm ~ 3.20mm)

Fully Insulated

Standard

1.5 mm2

-

Butted Seam

-

23.622mm

-

0.930 23.62mm

-

0.032 0.81mm

0.250 6.35mm

-

No

-

ROHS3 Compliant

Lead Free

1256
1256

Keystone Electronics

1719

-

Datasheet

6 Weeks

Tin

Chassis, Rivet

Board, Chassis

-

-

-

-

Brass

Thermoplastic

Bulk

-

-

yes

Active

1 (Unlimited)

Screw, Rivet, Stud

EAR99

-

-

145°C

-50°C

-

Male

8536.90.40.00

500V

Right Angle

-

15A

-

500V

-

-

-

-

-

-

-

PCB TERMINAL

-

Non-Insulated

Angled - 90°

-

-

-

-

7.92mm

-

-

-

0.032 0.81mm

0.250 6.35mm

812.8μm

-

No SVHC

ROHS3 Compliant

Lead Free

1544508-1
1544508-1

TE Connectivity

100
Datasheet

12 Weeks

Tin

Free Hanging

-

-

Brass

-

-

-

-

Tape & Reel (TR)

2005

-

-

Active

-

Tab

EAR99

-

-

-

-

-

Male

8536.90.40.00

-

-

3mm

-

-

-

IEC

-

Compliant

17 AWG

24 AWG

-

17 AWG

-

2.794 mm

Non-Insulated

-

-

-

-

-

-

-

-

-

508μm

2.794mm

-

No

-

RoHS Compliant

Not Applicable