Filters
  • Manufacturer
    • TE Connectivity
    • Molex
    • Panduit
    • 3M
    • Lapp
    • NTE ELECT
    • Keystone Electronics Corp
    • Greenlee Klauke
    • Phoenix Contact
    • Wurth Electronics
    • AMP
    • JST
    • Master Appliance
    • Remington
    • Brady Corporation
    • HEYCO PRODUCTS
    • interlight
    • Littelfuse
    • Weidmuller
    • Texas Instruments
    • Harwin
    • RS Pro
    • ABB
    • Adafruit
    • Greenlee
    • Desco
    • Raychem
    • Amphenol
    • Eaton
    • Cooper Bussmann
    • Multicomp
    • Wiha
    • Advanced
    • Schneider
    • EAO
    • Honeywell
    • SMC Corporation
    • SparkFun
    • C&K
    • Cooper
    • Finder
    • FLUKE
    • FLUKE Pomona
    • HellermannTyton
    • National Semiconductor
    • Norgren
    • Ohmite
    • Panasonic
    • Rockwell
    • Schurter
    • SK Hand Tool
    • STMicroelectronics
    • Elesa USA Corporation
    • Abracon
    • Alpha and Omega
    • Altech
    • Apex Tool Group
    • Astro Tool
    • Belden
    • Cypress
    • EMC
    • Fairchild
    • Glenair
    • Klein Tools
    • Lantronix
    • Lumberg Automation
    • Menda
    • Mitutoyo
    • Murata
    • Omron
    • PIC GmbH
    • Radiall
    • SICK
    • Visual
    • Wakefield
    • WECO
  • Gender
  • Insulation
  • RoHS Status
  • Termination
  • Width - Tab
  • Tab Thickness
  • Factory Lead Time
  • Packaging
  • Part Status
  • Length
  • Mount
  • Contact Materials

Attribute column

Categories

Terminals - Quick Connects, Quick Disconnect Connectors

View Mode:
5946 Results

Product

Inventory

Pricing(USD)

Quantity

Datasheet

RoHS

Factory Lead Time

Lifecycle Status

Contact Plating

Mount

Mounting Type

Package / Case

Weight

Body Material

Terminal Material

Contact Materials

Insulation Materials

Voltage Rated

Packaging

Published

Series

JESD-609 Code

Pbfree Code

Part Status

Moisture Sensitivity Level (MSL)

Termination

ECCN Code

Connector Type

Max Operating Temperature

Min Operating Temperature

Color

Gender

HTS Code

Voltage - Rated DC

Pitch

Orientation

Depth

Reach Compliance Code

Current Rating

Contact Finish

Voltage - Rated AC

Approval Agency

Number of Contacts

Wire Gauge

ELV

Connector Support Type

Wire Gauge (Max)

Wire Gauge (Min)

Wire/Cable Gauge

Sealable

Terminal and Terminal Block Type

Insulation Diameter

Insulation

Terminal Type

Wire Cross Section

Mating Tab Width

Insulated Wire Support

Length - Tab

Features

Diameter

Height

Length

Width

Length - Overall

Diameter - Inside

Tab Thickness

Width - Tab

Radiation Hardening

REACH SVHC

RoHS Status

Flammability Rating

Lead Free

DNF14-206-C
DNF14-206-C

Panduit Corp

39
-

4 Weeks

-

Tin

Free Hanging

Free Hanging (In-Line)

-

-

-

-

Brass

Nylon

-

Bulk

2007

Pan-Term®

-

-

Active

Not Applicable

Crimp

-

INTERCONNECTION DEVICE

-

-

Blue

Female

-

-

-

-

6.4mm

-

-

-

-

-

-

14-16 AWG

-

-

16 AWG

14 AWG

-

-

-

0.162 (4.11mm)

Non-Mating End Insulated

Standard

-

-

-

-

Serrated Termination

-

-

19.304mm

6.35mm

0.760 19.30mm

-

0.020 0.51mm

0.187 4.75mm 0.205 5.21mm

No

-

ROHS3 Compliant

-

-

DV14-250P-M
DV14-250P-M

Panduit Corp

In Stock

-

-

4 Weeks

-

-

Free Hanging

Free Hanging (In-Line)

-

-

-

-

-

Vinyl

-

Bulk

2009

Pan-Term®

e3

-

Obsolete

Not Applicable

Crimp

-

INTERCONNECTION DEVICE

-

-

Blue

Female and Male

-

-

-

Straight

7.4mm

-

-

-

-

-

-

14-16 AWG

-

-

16 AWG

14 AWG

-

-

-

0.160 (4.06mm)

Non-Mating End Insulated

Stacked

-

-

-

-

Serrated Termination

-

-

22.4mm

7.37mm

0.880 22.35mm

-

0.032 0.81mm

0.250 6.35mm

No

-

ROHS3 Compliant

-

-

DNF18-206-M
DNF18-206-M

Panduit Corp

14
-

4 Weeks

-

Tin

Free Hanging

Free Hanging (In-Line)

-

-

-

-

Brass

Nylon

-

Bulk

2007

Pan-Term®

-

-

Active

Not Applicable

Crimp

EAR99

-

-

-

Red

Female

8536.90.40.00

-

-

-

6.4mm

-

-

-

-

-

-

18-22 AWG

-

-

22 AWG

18 AWG

-

-

PUSH-ON TERMINAL

0.137 (3.48mm)

Non-Mating End Insulated

Standard

1 mm2

-

-

-

Serrated Termination

-

-

19.304mm

-

0.760 19.30mm

-

0.020 0.51mm

0.187 4.75mm 0.205 5.21mm

No

-

ROHS3 Compliant

-

-

DNF18-187FIB-3K
DNF18-187FIB-3K

Panduit Corp

279000
Datasheet

4 Weeks

-

Tin

Free Hanging

Free Hanging (In-Line)

-

-

-

-

Brass

-

-

Tape & Reel (TR)

2011

Disco™ ReelSmart™

-

-

Active

Not Applicable

Crimp

EAR99

-

-

-

Red

Female

8536.90.40.00

-

-

-

7.4mm

-

-

-

-

-

-

18-22 AWG

-

-

22 AWG

18 AWG

-

-

PUSH-ON TERMINAL

0.136 (3.45mm)

Fully Insulated

Standard

-

-

-

-

Butted Seam

-

-

19.812mm

-

0.780 19.81mm

-

0.032 0.81mm

0.187 4.75mm

No

-

ROHS3 Compliant

-

-

4916
4916

Keystone Electronics

26
Datasheet

6 Weeks

-

-

Through Hole

Through Hole

-

-

-

-

Brass

-

-

Bulk

-

-

-

-

Active

1 (Unlimited)

Solder

EAR99

-

-

-

-

Male

8536.90.40.00

-

-

-

-

-

-

Tin

-

-

-

-

-

-

-

-

-

-

TAB TERMINAL

-

Non-Insulated

Angled - 30°

-

-

-

0.217 5.50mm

-

-

-

-

-

-

-

0.020 0.51mm

0.110 2.79mm

-

-

ROHS3 Compliant

-

-

2953
Datasheet

3 Weeks

-

Tin

Free Hanging

Free Hanging (In-Line)

-

746.159449g

-

-

Brass

Vinyl

1kV

Bulk

2000

Scotchlok™

-

-

Active

1 (Unlimited)

Crimp

-

-

-

-

Red

Female

-

-

-

-

4.74mm

-

-

-

-

-

-

18-22 AWG

-

-

22 AWG

18 AWG

-

-

-

0.145 (3.68mm)

Non-Mating End Insulated

Standard

-

-

-

-

Butted Seam

-

-

19.812mm

-

0.780 19.81mm

-

0.020 0.51mm

0.187 4.75mm

-

-

RoHS Compliant

-

-

3578
3578

Keystone Electronics

1663
Datasheet

6 Weeks

-

Nickel, Tin

Through Hole

Through Hole

-

-

-

-

Brass

-

-

Bulk

-

-

-

-

Active

1 (Unlimited)

Solder

EAR99

-

-

-

-

Female

8536.90.40.00

-

-

Straight

-

-

-

Tin

-

-

-

-

-

-

-

-

-

-

TAB TERMINAL

-

Non-Insulated

Standard

-

-

-

0.270 6.86mm

-

-

-

10.668mm

-

0.420 10.67mm

-

0.016 0.41mm

-

-

-

ROHS3 Compliant

-

-

8276
8276

Keystone Electronics

26
Datasheet

6 Weeks

-

-

Free Hanging

Free Hanging (In-Line)

-

-

-

-

Copper

Vinyl

-

Bulk

-

-

-

-

Active

1 (Unlimited)

Crimp

EAR99

-

-

-

Red

Female

8536.90.40.00

-

-

Straight

-

-

-

Tin

-

-

-

18-22 AWG

-

-

22 AWG

18 AWG

-

-

PUSH-ON TERMINAL

0.145 (3.68mm)

Non-Mating End Insulated

Standard

-

-

-

-

-

-

-

19.812mm

4.75mm

0.780 19.81mm

-

0.020 0.51mm

0.187 4.75mm

-

-

ROHS3 Compliant

-

Lead Free

DV18-206B-MY
DV18-206B-MY

Panduit Corp

In Stock

-

Datasheet

4 Weeks

-

Tin

Free Hanging

Free Hanging (In-Line)

-

-

-

-

Brass

-

-

Bulk

2006

Pan-Term®

-

-

Active

Not Applicable

Crimp

EAR99

-

-

-

Red

Female

8536.90.40.00

-

-

-

6.4mm

-

-

-

-

-

-

18-22 AWG

-

-

22 AWG

18 AWG

-

-

PUSH-ON TERMINAL

0.150 (3.81mm)

Non-Mating End Insulated

Standard

-

-

-

-

Butted Seam

-

-

18.8976mm

-

0.744 18.90mm

-

0.020 0.51mm

0.187 4.75mm 0.205 5.21mm

No

-

ROHS3 Compliant

-

-

26
Datasheet

4 Weeks

-

Tin

Through Hole

Through Hole

-

-

-

-

Brass

-

-

Tape & Reel (TR)

-

19705

-

yes

Active

1 (Unlimited)

Solder

EAR99

-

-

-

-

Male

8536.90.40.00

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

TAB TERMINAL

-

Non-Insulated

Standard

-

-

-

0.470 11.94mm

-

-

-

14.224mm

-

0.707 17.96mm

-

0.032 0.81mm

0.187 4.75mm

-

-

ROHS3 Compliant

-

-

DVF14-205-C
DVF14-205-C

Panduit Corp

198
-

4 Weeks

-

Tin

Free Hanging

Free Hanging (In-Line)

-

-

Copper

-

Brass

Vinyl

-

Bulk

2005

Pan-Term®

-

-

Active

Not Applicable

Crimp

-

INTERCONNECTION DEVICE

-

-

Blue

Female

-

-

-

-

6.4mm

-

-

-

-

-

-

14-16 AWG

-

-

16 AWG

14 AWG

-

-

-

0.162 (4.11mm)

Non-Mating End Insulated

Standard

-

-

-

-

-

-

-

19.304mm

6.35mm

0.760 19.30mm

-

0.032 0.81mm

0.187 4.75mm 0.205 5.21mm

No

-

ROHS3 Compliant

-

-

3240058
3240058

Phoenix Contact

139
Datasheet

4 Weeks

-

-

Free Hanging

Free Hanging (In-Line)

-

-

-

-

Brass

PVC

-

Bulk

2013

CLIPLINE

-

-

Active

1 (Unlimited)

Crimp

EAR99

-

105°C

-20°C

Red

Male

8536.90.40.00

-

-

-

-

unknown

-

Tin

-

-

-

16-20 AWG

-

-

20 AWG

16 AWG

-

-

TAB TERMINAL

-

Non-Mating End Insulated

Standard

1.5 mm2

-

-

-

-

-

-

22mm

-

0.866 22.00mm

-

0.032 0.81mm

0.250 6.35mm

-

-

RoHS Compliant

-

-

22500
Datasheet

5 Weeks

-

Tin

Free Hanging

Free Hanging (In-Line)

-

-

-

-

Brass

PVC

-

Tape & Reel (TR)

-

InsulKrimp

-

-

Active

1 (Unlimited)

Crimp

-

-

105°C

-50°C

Red

Female

-

600V

-

Straight

6.09mm

-

-

-

-

-

-

18-22 AWG

-

-

22 AWG

18 AWG

-

-

PUSH-ON TERMINAL

0.130 (3.30mm)

Non-Mating End Insulated

Standard

-

-

-

0.250 6.35mm

-

-

-

19.812mm

-

0.780 19.81mm

-

0.032 0.81mm

0.187 4.75mm

-

-

ROHS3 Compliant

-

-

976
Datasheet

3 Weeks

-

Tin

Free Hanging

Free Hanging (In-Line)

100

1.723651kg

-

Copper

Copper

Nylon

-

Bulk

2002

Highland™

-

-

Active

1 (Unlimited)

Crimp

-

-

-

-

Red

Male

-

-

-

Straight

-

-

-

Tin

-

-

-

18-22 AWG

-

-

22 AWG

18 AWG

22 AWG

-

-

0.145 (3.68mm)

Fully Insulated

Standard

-

-

-

-

Butted Seam

-

-

24.13mm

6.35mm

0.950 24.13mm

-

0.032 0.81mm

0.250 6.35mm

-

Unknown

RoHS Compliant

-

Lead Free

SRSF-61T-250A
SRSF-61T-250A

JST Sales America Inc.

15000
-

16 Weeks

-

-

Free Hanging

Free Hanging (In-Line)

-

-

-

-

Brass

-

-

Tape & Reel (TR)

2004

-

-

-

Active

1 (Unlimited)

Crimp

-

-

-

-

-

Female

-

-

5mm

Straight

-

-

-

Tin

-

-

-

14-18 AWG

-

CONNECTOR ACCESSORY

18 AWG

14 AWG

-

-

-

-

Non-Insulated

Standard

-

-

-

0.252 6.40mm

-

-

-

20.9042mm

-

0.823 20.90mm

-

-

0.250 6.35mm

-

-

RoHS Compliant

-

Lead Free

1271
1271

Keystone Electronics

1952
Datasheet

6 Weeks

-

-

Chassis, Rivet

Board, Chassis

-

-

-

-

Brass

-

-

Bulk

-

-

-

yes

Active

1 (Unlimited)

Screw, Rivet, Stud

EAR99

-

-

-

-

Male

8536.90.40.00

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

PCB TERMINAL

-

Non-Insulated

Angled - 45°

-

-

-

-

-

2.5146mm

-

6.35mm

-

-

-

0.020 0.51mm

0.187 4.75mm

-

-

ROHS3 Compliant

-

Lead Free

D18-188-C
D18-188-C

Panduit Corp

22
-

4 Weeks

-

-

Free Hanging

Free Hanging (In-Line)

-

99.790321g

-

-

Brass

-

-

Bulk

2005

Pan-Term®

-

-

Active

Not Applicable

Crimp

EAR99

-

-

-

Red

Female

8536.90.40.00

-

-

-

5.8mm

-

-

Tin

-

-

-

18-22 AWG

-

-

22 AWG

18 AWG

-

-

PUSH-ON TERMINAL

-

Non-Insulated

Standard

1 mm2

-

-

-

Serrated Termination

-

-

14.732mm

5.84mm

0.580 14.73mm

-

0.020 0.51mm

0.187 4.75mm

No

-

ROHS3 Compliant

-

-

4906
4906

Keystone Electronics

3624
Datasheet

6 Weeks

-

-

Through Hole

Through Hole, Right Angle

052

-

-

-

Brass

-

-

Bulk

-

-

-

yes

Active

1 (Unlimited)

Solder

EAR99

-

-

-

-

Male

8536.90.40.00

-

-

Right Angle

11.04mm

-

20A

Tin

-

-

1

-

-

-

-

-

-

-

TAB TERMINAL

-

Non-Insulated

Standard

-

-

-

-

-

1.3208mm

7.49mm

13.34mm

-

-

1.22 mm

0.032 0.81mm

0.110 2.79mm

-

No SVHC

ROHS3 Compliant

-

Lead Free

DNF14-110-M
DNF14-110-M

Panduit Corp

6
-

4 Weeks

-

Tin

Free Hanging

Free Hanging (In-Line)

-

907.18474g

-

-

Brass

Nylon

-

Bulk

2005

Pan-Term®

-

-

Active

Not Applicable

Crimp

EAR99

-

-

-

Blue

Female

8536.90.40.00

-

-

-

-

-

-

-

-

-

-

14-16 AWG

-

-

14 AWG

16 AWG

-

-

PUSH-ON TERMINAL

0.162 (4.11mm)

Non-Mating End Insulated

Standard

-

-

-

-

Serrated Termination

-

-

19.05mm

3.81mm

0.750 19.05mm

-

0.032 0.81mm

0.110 2.79mm

No

-

ROHS3 Compliant

-

-

8-640929-1
8-640929-1

TE Connectivity AMP Connectors

In Stock

-

-

12 Weeks

ACTIVE (Last Updated: 6 days ago)

-

Free Hanging

Free Hanging (In-Line)

-

-

-

-

Brass

Nylon

-

Bulk

2006

Faston, PIDG

-

yes

Active

1 (Unlimited)

Crimp

EAR99

-

-

-

Blue

Female

8536.90.40.00

-

-

Straight

-

-

-

Tin

300V

CSA

-

14-16 AWG

Compliant

-

14 AWG

16 AWG

14 AWG

No

WIRE TERMINAL

0.170 (4.32mm)

Non-Mating End Insulated

Standard

-

2.794mm

Yes

0.250 6.35mm

-

-

-

20.3mm

-

0.800 20.32mm

-

0.020 0.51mm

0.110 2.79mm

-

Unknown

RoHS Compliant

UL94 V-2

Lead Free