Filters
  • Manufacturer
    • TE Connectivity
    • Molex
    • Panduit
    • 3M
    • Lapp
    • NTE ELECT
    • Keystone Electronics Corp
    • Greenlee Klauke
    • Phoenix Contact
    • Wurth Electronics
    • AMP
    • JST
    • Master Appliance
    • Remington
    • Brady Corporation
    • HEYCO PRODUCTS
    • interlight
    • Littelfuse
    • Weidmuller
    • Texas Instruments
    • Harwin
    • RS Pro
    • ABB
    • Adafruit
    • Greenlee
    • Desco
    • Raychem
    • Amphenol
    • Eaton
    • Cooper Bussmann
    • Multicomp
    • Wiha
    • Advanced
    • Schneider
    • EAO
    • Honeywell
    • SMC Corporation
    • SparkFun
    • C&K
    • Cooper
    • Finder
    • FLUKE
    • FLUKE Pomona
    • HellermannTyton
    • National Semiconductor
    • Norgren
    • Ohmite
    • Panasonic
    • Rockwell
    • Schurter
    • SK Hand Tool
    • STMicroelectronics
    • Elesa USA Corporation
    • Abracon
    • Alpha and Omega
    • Altech
    • Apex Tool Group
    • Astro Tool
    • Belden
    • Cypress
    • EMC
    • Fairchild
    • Glenair
    • Klein Tools
    • Lantronix
    • Lumberg Automation
    • Menda
    • Mitutoyo
    • Murata
    • Omron
    • PIC GmbH
    • Radiall
    • SICK
    • Visual
    • Wakefield
    • WECO
  • Gender
  • Insulation
  • RoHS Status
  • Termination
  • Width - Tab
  • Tab Thickness
  • Factory Lead Time
  • Packaging
  • Part Status
  • Length
  • Mount
  • Contact Materials

Attribute column

Categories

Terminals - Quick Connects, Quick Disconnect Connectors

View Mode:
5946 Results

Product

Inventory

Pricing(USD)

Quantity

Datasheet

RoHS

Factory Lead Time

Contact Plating

Mount

Mounting Type

Package / Case

Number of Pins

Material

Weight

Body Material

Contact Materials

Insulation Materials

Voltage Rated

Packaging

Published

Series

Pbfree Code

Part Status

Moisture Sensitivity Level (MSL)

Termination

ECCN Code

Connector Type

Max Operating Temperature

Min Operating Temperature

Color

Gender

HTS Code

Voltage - Rated DC

Orientation

Depth

Current Rating

Contact Finish

Voltage - Rated AC

Approval Agency

Wire Gauge

ELV

Wire Gauge (Max)

Wire Gauge (Min)

Body Plating

Wire/Cable Gauge

Terminal and Terminal Block Type

Halogen Free

Insulation Diameter

Insulation

Terminal Type

Wire Cross Section

Glow Wire Compliant

Length - Tab

Features

Height

Length

Width

Length - Overall

Tab Thickness

Width - Tab

Material Thickness

Radiation Hardening

REACH SVHC

RoHS Status

Flammability Rating

Lead Free

93
Datasheet

3 Weeks

Tin

Free Hanging

Free Hanging (In-Line)

-

-

-

498.951607g

-

Copper

Nylon

-

Bulk

2000

Scotchlok™

-

Active

1 (Unlimited)

Crimp

-

-

-

-

Red

Male

-

-

-

11.17mm

-

-

-

-

18-22 AWG

-

22 AWG

18 AWG

-

-

-

-

-

Fully Insulated Heat Shrink

Standard

-

-

-

Butted Seam

-

30.48mm

-

1.200 30.48mm

0.032 0.81mm

0.250 6.35mm

-

-

-

RoHS Compliant

-

-

22
Datasheet

9 Weeks

Tin

-

Free Hanging (In-Line)

Molded

-

Brass

-

Brass

Brass

Nylon

600V

Reel

-

InsulKrimp

-

Active

1 (Unlimited)

Crimp

-

-

105°C

-65°C

Pink

Female

-

-

Straight

8.03mm

-

Electro-Tin

-

-

18-22 AWG

Compliant

18 AWG

22 AWG

Tin

-

-

Low Halogen

0.230 (5.84mm)

Fully Insulated

Standard

-

Non-compliant

-

-

-

21.8mm

-

0.860 21.84mm

0.032 0.81mm

0.187 4.75mm

-

-

-

ROHS3 Compliant

UL94 V-2

-

DNG14-250FB-3K
DNG14-250FB-3K

Panduit Corp

3988
-

4 Weeks

-

Free Hanging

Free Hanging (In-Line)

-

-

-

-

-

Brass

-

-

Tape & Reel (TR)

2006

ReelSmart™ Supra-Grip™

-

Active

Not Applicable

Crimp

EAR99

-

-

-

Blue

Female

8536.90.40.00

-

-

-

-

Tin

-

-

14-16 AWG

-

16 AWG

14 AWG

-

-

WIRE TERMINAL

-

0.125 ~ 0.153 (3.18mm ~ 3.89mm)

Fully Insulated

Standard

2.5 mm2

-

-

Butted Seam

-

23.622mm

-

0.930 23.62mm

0.032 0.81mm

0.250 6.35mm

-

-

-

ROHS3 Compliant

-

Lead Free

DPF18-250FIB-M
DPF18-250FIB-M

Panduit Corp

1391
Datasheet

4 Weeks

Tin

Free Hanging

Free Hanging (In-Line)

-

-

-

1.133981kg

Copper

Brass

Nylon

-

Bulk

2001

DiscoGrip™

-

Active

Not Applicable

Crimp

-

INTERCONNECTION DEVICE

-

-

Red

Female

-

-

-

8.9mm

-

-

-

-

18-22 AWG

-

18 AWG

22 AWG

-

-18 AWG

-

-

0.080 ~ 0.133 (2.03mm ~ 3.38mm)

Fully Insulated

Standard

-

-

-

-

-

21.3mm

8.89mm

0.840 21.34mm

0.032 0.81mm

0.250 6.35mm

-

No

No SVHC

ROHS3 Compliant

-

Lead Free

882
Datasheet

3 Weeks

-

Free Hanging

Free Hanging (In-Line)

100

-

-

1.17934kg

-

Copper

Vinyl

-

Bulk

2002

Highland™

-

Active

1 (Unlimited)

Crimp

-

-

-

-

Red

Male

-

-

Straight

-

-

Tin

-

-

18-22 AWG

-

22 AWG

18 AWG

-

18 AWG

-

-

0.145 (3.68mm)

Non-Mating End Insulated

Standard

-

-

-

Butted Seam

-

24.13mm

6.35mm

0.950 24.13mm

0.032 0.81mm

0.250 6.35mm

-

-

Unknown

RoHS Compliant

-

Contains Lead

8288
8288

Keystone Electronics

22
Datasheet

6 Weeks

-

Free Hanging

Free Hanging (In-Line)

-

-

-

-

-

Copper

Vinyl

-

Bulk

-

-

-

Active

1 (Unlimited)

Crimp

EAR99

-

-

-

Blue

Male

8536.90.40.00

-

Straight

-

-

Tin

-

-

14-16 AWG

-

16 AWG

14 AWG

-

-14 AWG

WIRE TERMINAL

-

0.145 (3.68mm)

Non-Mating End Insulated

Standard

-

-

-

-

-

21.59mm

4.75mm

0.850 21.59mm

0.020 0.51mm

0.187 4.75mm

-

-

-

Non-RoHS Compliant

-

Contains Lead

1022
Datasheet

3 Weeks

Tin

Free Hanging

Free Hanging (In-Line)

-

-

-

1.678292kg

-

Brass

Nylon

-

Bulk

2008

Scotchlok™

-

Active

1 (Unlimited)

Crimp

-

-

-

-

Blue

Female

-

-

-

-

-

Tin

-

-

14-16 AWG

-

16 AWG

14 AWG

-

-

-

-

0.145 (3.68mm)

Fully Insulated

Standard

-

-

-

-

-

22.098mm

-

0.870 22.10mm

0.032 0.81mm

0.250 6.35mm

-

-

-

RoHS Compliant

-

-

25
Datasheet

9 Weeks

-

-

Free Hanging (In-Line)

-

-

-

-

-

Brass

-

-

Tape & Reel (TR)

-

Avikrimp

yes

Active

1 (Unlimited)

Crimp

-

-

-

-

Blue

Female and Male

-

-

-

-

-

Tin

-

-

14-16 AWG

-

-

-

-

-

PUSH-ON TERMINAL

-

0.139 (3.53mm)

Fully Insulated

Stacked

-

-

0.310 7.87mm

-

-

-

-

0.880 22.35mm

0.032 0.81mm

0.250 6.35mm

-

-

-

ROHS3 Compliant

-

-

DNF14-187-M
DNF14-187-M

Panduit Corp

In Stock

-

-

4 Weeks

Tin

Free Hanging

Free Hanging (In-Line)

-

-

-

1.111301kg

-

Brass

Nylon

-

Bulk

2005

Pan-Term®

-

Active

Not Applicable

Crimp

EAR99

-

-

-

Blue

Female

8536.90.40.00

-

-

5.8mm

-

-

-

-

14-16 AWG

-

16 AWG

14 AWG

-

-

PUSH-ON TERMINAL

-

0.162 (4.11mm)

Non-Mating End Insulated

Standard

-

-

-

Serrated Termination

-

19.3mm

5.84mm

0.760 19.30mm

0.032 0.81mm

0.187 4.75mm

-

No

-

ROHS3 Compliant

-

-

DNF18-206-C
DNF18-206-C

Panduit Corp

64
-

4 Weeks

-

Free Hanging

Free Hanging (In-Line)

-

-

-

-

-

Brass

Nylon

-

Bulk

2007

Pan-Term®

-

Active

Not Applicable

Crimp

-

INTERCONNECTION DEVICE

-

-

Red

Female

-

-

-

-

-

Tin

-

-

18-22 AWG

-

22 AWG

18 AWG

-

-

-

-

0.137 (3.48mm)

Non-Mating End Insulated

Standard

-

-

-

Serrated Termination

-

19.304mm

6.35mm

0.760 19.30mm

0.020 0.51mm

0.187 4.75mm 0.205 5.21mm

-

No

-

ROHS3 Compliant

-

-

In Stock

-

Datasheet

3 Weeks

-

Free Hanging

Free Hanging (In-Line)

-

-

-

317.514659g

-

Copper, ETP

Vinyl

-

Bulk

2002

Highland™

-

Obsolete

1 (Unlimited)

Crimp

-

-

-

-

Blue

Male

-

-

Straight

-

-

Tin

-

CSA, UL

14-16 AWG

-

16 AWG

14 AWG

-

14 AWG

-

-

0.145 (3.68mm)

Non-Mating End Insulated

Standard

-

-

-

Butted Seam

114.3mm

21.59mm

139.7mm

0.850 21.59mm

0.020 0.51mm

0.187 4.75mm

-

-

-

RoHS Compliant

-

-

7823
7823

Keystone Electronics

22

-

Datasheet

6 Weeks

-

Through Hole

Through Hole, Right Angle

-

3

-

-

-

Steel

Thermoplastic

-

Bulk

-

-

yes

Active

1 (Unlimited)

Solder

EAR99

INTERCONNECTION DEVICE

-

-

Black

Male

-

-

Right Angle

-

-

Tin

-

-

-

-

-

-

-

-

-

-

-

Non-Mating End Insulated

Header

-

-

0.307 7.80mm

3 Tabs

-

9.19mm

-

-

0.032 0.81mm

0.250 6.35mm

-

-

-

ROHS3 Compliant

-

Lead Free

1233
1233

Keystone Electronics

763
Datasheet

6 Weeks

-

Chassis

Board, Chassis

-

-

-

-

-

Tin

-

-

Bulk

-

-

-

Active

1 (Unlimited)

Screw, Rivet, Stud

EAR99

-

-

-

-

Male

8536.90.40.00

-

-

-

-

-

-

-

-

-

-

-

-

-

TAB TERMINAL

-

-

Non-Insulated

Angled - 45°

-

-

-

-

-

-

-

-

0.020 0.51mm

0.110 2.79mm

-

-

-

ROHS3 Compliant

-

-

22
-

3 Weeks

Tin

Free Hanging

Free Hanging (In-Line)

-

-

-

2.449399g

-

Brass

-

-

Bulk

2002

-

-

Active

1 (Unlimited)

Crimp

-

-

-

-

Yellow

Female

-

-

-

9.52mm

-

-

-

-

10-12 AWG

-

12 AWG

10 AWG

-

-

-

-

0.250 (6.35mm)

Non-Mating End Insulated

Standard

-

-

-

-

-

31.242mm

-

1.230 31.24mm

0.050 1.27mm

0.375 9.53mm

-

-

-

RoHS Compliant

-

-

DNF18-187-C
DNF18-187-C

Panduit Corp

100
-

4 Weeks

Tin

Free Hanging

Free Hanging (In-Line)

-

-

-

122.46994g

-

Brass

Nylon

300V

Bulk

2005

Pan-Term®

-

Active

Not Applicable

Crimp

-

INTERCONNECTION DEVICE

-

-

Red

Female

-

-

-

5.8mm

-

-

-

-

18-22 AWG

-

22 AWG

18 AWG

-

-

-

-

0.137 (3.48mm)

Non-Mating End Insulated

Standard

-

-

-

Serrated Termination

-

19.3mm

5.8mm

0.760 19.30mm

0.032 0.81mm

0.187 4.75mm

-

No

-

ROHS3 Compliant

-

-

3240154
3240154

Phoenix Contact

In Stock
Datasheet

4 Weeks

Tin

Free Hanging

Free Hanging (In-Line)

Metal

-

Brass

-

-

Brass

-

-

Bulk

2011

CLIPLINE

-

Active

1 (Unlimited)

Crimp

-

-

-

-

-

Female

-

-

-

-

-

Tin

-

-

16-20 AWG

-

20 AWG

16 AWG

-

-

-

-

-

Non-Insulated

Standard

-

-

-

-

-

15.5956mm

-

0.614 15.60mm

0.020 0.51mm

0.187 4.75mm

-

-

-

RoHS Compliant

-

-

DV18-205B-MY
DV18-205B-MY

Panduit Corp

In Stock

-

-

4 Weeks

Tin

Free Hanging

Free Hanging (In-Line)

-

-

-

-

-

Brass

-

-

Bulk

2006

Pan-Term®

-

Active

Not Applicable

Crimp

EAR99

-

-

-

Red

Female

8536.90.40.00

-

-

6.4mm

-

-

-

-

18-22 AWG

-

22 AWG

18 AWG

-

-

PUSH-ON TERMINAL

-

0.150 (3.81mm)

Non-Mating End Insulated

Standard

-

-

-

Butted Seam

-

19.05mm

-

0.750 19.05mm

0.032 0.81mm

0.187 4.75mm 0.205 5.21mm

-

No

-

ROHS3 Compliant

-

-

DNFR18-206B-L
DNFR18-206B-L

Panduit Corp

In Stock

-

-

4 Weeks

Tin

Free Hanging

Free Hanging (In-Line), Right Angle

-

-

-

-

-

Brass

-

-

Bulk

2011

Pan-Term®

-

Active

Not Applicable

Crimp

EAR99

-

-

-

Red

Female

8536.90.40.00

-

-

9.1mm

-

-

-

-

18-22 AWG

-

22 AWG

18 AWG

-

-

PUSH-ON TERMINAL

-

0.130 (3.30mm)

Fully Insulated

Angled - 90°, Flag

1 mm2

-

-

-

-

19.8mm

-

-

0.020 0.51mm

0.187 4.75mm 0.205 5.21mm

-

No

-

ROHS3 Compliant

-

-

1258
1258

Keystone Electronics

3156
Datasheet

6 Weeks

Tin

Chassis, Rivet

Board, Chassis

-

-

-

-

-

Brass

Thermoplastic

-

Bulk

2012

-

yes

Active

1 (Unlimited)

Screw, Rivet, Stud

EAR99

-

145°C

-50°C

-

Male

8536.90.40.00

500V

-

-

15A

-

500V

-

-

-

-

-

-

-

PCB TERMINAL

-

-

Non-Insulated

Angled - 45°

-

-

-

2 Tabs

-

7.92mm

-

-

0.032 0.81mm

0.250 6.35mm

812.8μm

-

No SVHC

ROHS3 Compliant

-

Lead Free

904

-

Datasheet

8 Weeks

-

Cable

Free Hanging (In-Line)

-

-

-

-

-

-

-

-

-

2009

31

-

Active

Not Applicable

Crimp

-

-

-

-

-

Female

-

-

-

-

-

-

-

-

-

-

-

-

-

-

PUSH-ON TERMINAL

-

-

Non-Insulated

Standard

-

-

-

-

-

-

-

-

-

-

-

-

No SVHC

ROHS3 Compliant

-

-