Filters
  • Manufacturer
    • TE Connectivity
    • Molex
    • Panduit
    • 3M
    • Lapp
    • NTE ELECT
    • Keystone Electronics Corp
    • Greenlee Klauke
    • Phoenix Contact
    • Wurth Electronics
    • AMP
    • JST
    • Master Appliance
    • Remington
    • Brady Corporation
    • HEYCO PRODUCTS
    • interlight
    • Littelfuse
    • Weidmuller
    • Texas Instruments
    • Harwin
    • RS Pro
    • ABB
    • Adafruit
    • Greenlee
    • Desco
    • Raychem
    • Amphenol
    • Eaton
    • Cooper Bussmann
    • Multicomp
    • Wiha
    • Advanced
    • Schneider
    • EAO
    • Honeywell
    • SMC Corporation
    • SparkFun
    • C&K
    • Cooper
    • Finder
    • FLUKE
    • FLUKE Pomona
    • HellermannTyton
    • National Semiconductor
    • Norgren
    • Ohmite
    • Panasonic
    • Rockwell
    • Schurter
    • SK Hand Tool
    • STMicroelectronics
    • Elesa USA Corporation
    • Abracon
    • Alpha and Omega
    • Altech
    • Apex Tool Group
    • Astro Tool
    • Belden
    • Cypress
    • EMC
    • Fairchild
    • Glenair
    • Klein Tools
    • Lantronix
    • Lumberg Automation
    • Menda
    • Mitutoyo
    • Murata
    • Omron
    • PIC GmbH
    • Radiall
    • SICK
    • Visual
    • Wakefield
    • WECO
  • Gender
  • Insulation
  • RoHS Status
  • Termination
  • Width - Tab
  • Tab Thickness
  • Factory Lead Time
  • Packaging
  • Part Status
  • Length
  • Mount
  • Contact Materials

Attribute column

Categories

Terminals - Quick Connects, Quick Disconnect Connectors

View Mode:
5946 Results

Product

Inventory

Pricing(USD)

Quantity

Datasheet

RoHS

Factory Lead Time

Contact Plating

Mount

Mounting Type

Package / Case

Material

Weight

Contact Materials

Insulation Materials

Voltage Rated

Packaging

Published

Series

Pbfree Code

Part Status

Moisture Sensitivity Level (MSL)

Termination

ECCN Code

Number of Positions

Color

Number of Rows

Gender

HTS Code

Orientation

Depth

Current Rating

Contact Finish

Wire Gauge

Wire Gauge (Max)

Wire Gauge (Min)

Wire/Cable Gauge

Terminal and Terminal Block Type

Insulation Diameter

Insulation

Terminal Type

Wire Cross Section

Length - Tab

Features

Height

Length

Width

Thickness

Length - Overall

Tab Thickness

Board Thickness

Width - Tab

Radiation Hardening

REACH SVHC

RoHS Status

Lead Free

DV18-188B-CY
DV18-188B-CY

Panduit Corp

In Stock

-

Datasheet

4 Weeks

Tin

Free Hanging

Free Hanging (In-Line)

-

Vinyl

86.18255g

Brass

-

600V

Bulk

2006

Pan-Term®

-

Active

Not Applicable

Crimp

EAR99

-

Red

-

Female

8536.90.40.00

-

5.8mm

-

-

18-22 AWG

22 AWG

18 AWG

18 AWG

BULLET TERMINAL

0.150 (3.81mm)

Non-Mating End Insulated

Standard

-

-

Butted Seam, Serrated Termination

-

19.3mm

-

-

0.150 3.81mm

0.020 0.51mm

-

0.187 4.75mm

No

No SVHC

ROHS3 Compliant

-

9200560000
9200560000

Weidmüller

230
Datasheet

8 Weeks

-

Free Hanging

Free Hanging (In-Line)

-

Copper

-

-

-

-

Bulk

2011

-

-

Active

1 (Unlimited)

Crimp

EAR99

-

Blue

-

Female

8536.90.40.00

-

-

-

-

-

-

-

-

PUSH-ON TERMINAL

-

Non-Mating End Insulated

Standard

-

-

-

-

20.8mm

7.7mm

-

0.819 20.80mm

0.032 0.81mm

-

0.250 6.35mm

-

-

RoHS Compliant

-

9200620000
9200620000

Weidmüller

125
Datasheet

8 Weeks

-

Free Hanging

Free Hanging (In-Line)

-

Copper

-

-

-

-

Bulk

2011

-

yes

Active

1 (Unlimited)

Crimp

-

-

Blue

-

Female and Male

-

-

-

-

-

-

-

-

-

PUSH-ON TERMINAL

-

Non-Mating End Insulated

Stacked

-

-

-

-

20.8mm

7.7mm

-

0.819 20.80mm

0.032 0.81mm

-

0.250 6.35mm

-

-

RoHS Compliant

-

9200600000
9200600000

Weidmüller

222
Datasheet

8 Weeks

-

Free Hanging

Free Hanging (In-Line)

-

Copper

-

-

-

-

Bulk

2011

-

-

Active

1 (Unlimited)

Crimp

EAR99

-

Yellow

-

Male

8536.90.40.00

-

-

-

-

-

-

-

-

TAB TERMINAL

-

Non-Mating End Insulated

Standard

-

-

-

-

23.8mm

8.2mm

-

0.937 23.80mm

0.032 0.81mm

-

0.250 6.35mm

-

-

RoHS Compliant

-

9200520000
9200520000

Weidmüller

422
Datasheet

8 Weeks

-

Free Hanging

Free Hanging (In-Line)

-

Copper

-

-

-

-

Bulk

2011

-

-

Active

1 (Unlimited)

Crimp

EAR99

-

Red

-

Female

8536.90.40.00

-

-

-

-

-

-

-

-

PUSH-ON TERMINAL

-

Non-Mating End Insulated

Standard

-

-

-

-

18.7mm

5.7mm

-

0.736 18.69mm

0.032 0.81mm

-

0.110 2.79mm

-

-

RoHS Compliant

-

977
Datasheet

7 Weeks

-

-

Through Hole

-

-

-

Brass

-

-

Tape & Reel (TR)

-

19705

yes

Active

1 (Unlimited)

Solder

EAR99

-

-

-

Male

8536.90.40.00

-

-

-

Tin

-

-

-

-

TAB TERMINAL

-

Non-Insulated

Standard

-

0.315 8.00mm

-

-

-

-

-

0.552 14.02mm

0.032 0.81mm

-

0.250 6.35mm

-

-

ROHS3 Compliant

-

DNFR18-205B-L
DNFR18-205B-L

Panduit Corp

46
-

4 Weeks

Tin

Free Hanging

Free Hanging (In-Line), Right Angle

-

-

-

Brass

-

-

Bulk

2011

Pan-Term®

-

Active

Not Applicable

Crimp

EAR99

-

Red

-

Female

8536.90.40.00

-

9.1mm

-

-

18-22 AWG

22 AWG

18 AWG

-

PUSH-ON TERMINAL

0.130 (3.30mm)

Fully Insulated

Angled - 90°, Flag

1 mm2

-

Butted Seam

-

19.8mm

-

-

-

0.032 0.81mm

-

0.187 4.75mm 0.205 5.21mm

No

-

ROHS3 Compliant

-

1007
1007

Keystone Electronics

1084
Datasheet

6 Weeks

Tin

Chassis, Rivet

Board, Chassis

-

-

-

Brass

Thermoplastic

-

Bulk

-

-

yes

Active

1 (Unlimited)

Screw, Rivet, Stud

EAR99

8

-

4

Male

-

Right Angle

-

15A

-

-

-

-

-

PCB TERMINAL

-

Non-Insulated

Angled - 90°

-

-

8 Tabs

10.3mm

36.12mm

8.71mm

813μm

-

-

812.8μm

0.250 6.35mm

-

No SVHC

ROHS3 Compliant

Lead Free

DPF18-206FIBR-C
DPF18-206FIBR-C

Panduit Corp

In Stock

-

Datasheet

4 Weeks

Tin

Free Hanging

Free Hanging (In-Line)

-

-

-

Brass

-

-

Bulk

2011

DiscoGrip™

-

Active

Not Applicable

Crimp

EAR99

-

Red

-

Female

8536.90.40.00

-

7.9mm

-

-

18-22 AWG

22 AWG

18 AWG

-

PUSH-ON TERMINAL

0.060 ~ 0.106 (1.52mm ~ 2.69mm)

Fully Insulated

Standard

-

-

Butted Seam

-

19.812mm

-

-

0.780 19.81mm

0.020 0.51mm

-

0.187 4.75mm 0.205 5.21mm

No

-

ROHS3 Compliant

-

DR14-205-C
DR14-205-C

Panduit Corp

46
-

4 Weeks

-

Free Hanging

Free Hanging (In-Line), Right Angle

-

-

-

Brass

-

-

Bulk

2006

Pan-Term®

-

Active

Not Applicable

Crimp

EAR99

-

-

-

Female

8536.90.40.00

-

-

-

Tin

14-16 AWG

16 AWG

14 AWG

-

PUSH-ON TERMINAL

-

Non-Insulated

Angled - 90°, Flag

-

-

Serrated Termination

-

13.7mm

6.35mm

-

-

0.032 0.81mm

-

0.187 4.75mm 0.205 5.21mm

No

-

ROHS3 Compliant

-

3240535
3240535

Phoenix Contact

In Stock
Datasheet

4 Weeks

-

Free Hanging

Free Hanging (In-Line)

-

-

-

Brass

PVC

-

Bulk

2013

CLIPLINE

yes

Active

1 (Unlimited)

Crimp

-

-

Red

-

Female

-

-

-

-

-

16-20 AWG

20 AWG

16 AWG

-

PUSH-ON TERMINAL

-

Fully Insulated

Standard

-

-

-

-

18.9992mm

-

-

0.748 19.00mm

0.032 0.81mm

-

0.110 2.79mm

-

-

RoHS Compliant

-

3637
Datasheet

3 Weeks

-

Free Hanging

Free Hanging (In-Line)

100

-

1.542214kg

Copper

Nylon

-

Bulk

2002

Highland™

-

Active

1 (Unlimited)

Crimp

-

-

Red

-

Male

-

Straight

-

-

Tin

18-22 AWG

22 AWG

18 AWG

18 AWG

-

0.145 (3.68mm)

Fully Insulated

Standard

-

-

Butted Seam

-

24.13mm

6.35mm

-

0.950 24.13mm

0.032 0.81mm

-

0.250 6.35mm

-

Unknown

RoHS Compliant

Lead Free

18

-

Datasheet

3 Weeks

Tin

Free Hanging

Free Hanging (In-Line)

-

-

1.043262kg

Brass

Nylon

-

Bulk

2002

Highland™

-

Active

1 (Unlimited)

Crimp

-

-

Yellow

-

Female

-

Straight

-

-

Tin

10-12 AWG

12 AWG

10 AWG

10 AWG

-

0.250 (6.35mm)

Fully Insulated

Standard

-

-

Butted Seam

-

25.146mm

6.35mm

-

0.990 25.15mm

0.032 0.81mm

-

0.250 6.35mm

-

-

RoHS Compliant

Lead Free

893
Datasheet

3 Weeks

-

Free Hanging

Free Hanging (In-Line)

-

-

-

Brass

-

-

Bulk

2000

Scotchlok™

-

Active

1 (Unlimited)

Crimp

-

-

Blue

-

Female

-

-

7.62mm

-

Tin

14-16 AWG

16 AWG

14 AWG

-

-

0.145 (3.68mm)

Fully Insulated

Standard

-

-

Butted Seam

-

20.574mm

-

-

0.810 20.57mm

0.020 0.51mm

-

0.187 4.75mm

-

-

RoHS Compliant

-

DNF14-205FIB-M
DNF14-205FIB-M

Panduit Corp

250
Datasheet

4 Weeks

Tin

Free Hanging

Free Hanging (In-Line)

-

-

-

Brass

Nylon

-

Bulk

2009

Pan-Term®

-

Active

Not Applicable

Crimp

EAR99

-

Blue

-

Female

8536.90.40.00

-

7.9mm

-

-

14-16 AWG

16 AWG

14 AWG

-

PUSH-ON TERMINAL

0.160 (4.06mm)

Fully Insulated

Standard

2.5 mm2

-

Serrated Termination

-

19.812mm

7.87mm

-

0.780 19.81mm

0.032 0.81mm

-

0.187 4.75mm 0.205 5.21mm

No

-

ROHS3 Compliant

-

3545
3545

Keystone Electronics

2005
Datasheet

6 Weeks

-

Through Hole

Through Hole

-

-

-

Brass

-

-

Bulk

-

-

yes

Active

1 (Unlimited)

Solder

EAR99

1

-

-

Female

8536.90.40.00

Right Angle

-

-

Nickel

-

-

-

-

PCB TERMINAL

-

Non-Insulated

Horizontal

-

0.280 7.11mm

-

-

10.2mm

-

-

-

0.020 0.51mm

-

0.110 2.79mm

-

-

ROHS3 Compliant

Lead Free

8278
8278

Keystone Electronics

In Stock

-

Datasheet

6 Weeks

-

Free Hanging

Free Hanging (In-Line)

-

-

-

Copper

Vinyl

-

Bulk

-

-

-

Active

1 (Unlimited)

Crimp

EAR99

-

Blue

-

Female

8536.90.40.00

Straight

-

-

Tin

14-16 AWG

16 AWG

14 AWG

-

PUSH-ON TERMINAL

0.145 (3.68mm)

Non-Mating End Insulated

Standard

-

-

-

-

19.812mm

4.75mm

-

0.780 19.81mm

0.020 0.51mm

-

0.187 4.75mm

-

-

Non-RoHS Compliant

Contains Lead

4470
4470

Keystone Electronics

2403
Datasheet

6 Weeks

-

Free Hanging

Free Hanging (In-Line)

-

-

-

Brass

-

-

Bulk

-

-

yes

Active

1 (Unlimited)

Crimp

EAR99

-

-

-

Female

8538.90.60.00

Straight

-

-

Tin

16-20 AWG

20 AWG

16 AWG

-

WIRE TERMINAL

-

Non-Insulated

Standard

-

-

-

-

19.05mm

-

-

0.750 19.05mm

0.020 0.51mm

-

0.250 6.35mm

-

-

ROHS3 Compliant

Lead Free

1270
1270

Keystone Electronics

822
Datasheet

6 Weeks

-

Chassis, Rivet

Board, Chassis

-

-

-

Brass

-

-

Bulk

-

-

yes

Active

1 (Unlimited)

Screw, Rivet, Stud

EAR99

-

-

-

Male

8536.90.40.00

-

-

-

Tin

-

-

-

-

PCB TERMINAL

-

Non-Insulated

Angled - 30°

-

-

-

-

15.7226mm

-

-

0.619 15.72mm

0.020 0.51mm

-

0.110 2.79mm

-

-

ROHS3 Compliant

Lead Free

DNF10-250FIMB-Q
DNF10-250FIMB-Q

Panduit Corp

44
-

4 Weeks

-

Free Hanging

Free Hanging (In-Line)

-

Brass

158.757329g

Copper

Nylon

-

Bulk

2011

Pan-Term®

-

Active

Not Applicable

Crimp

-

-

Yellow

-

Male

-

Straight

-

-

Nickel

10-12 AWG

10 AWG

12 AWG

-

TAB TERMINAL

0.220 (5.59mm)

Fully Insulated

Standard

-

-

Serrated Termination

-

24.384mm

-

-

0.960 24.38mm

0.032 0.81mm

-

0.250 6.35mm

No

-

ROHS3 Compliant

-