Product | Inventory | Pricing(USD) | Quantity | Datasheet | RoHS | Factory Lead Time | Lifecycle Status | Contact Plating | Mount | Mounting Type | Package / Case | Material | Weight | Body Material | Contact Materials | Insulation Materials | Voltage Rated | Packaging | Published | Series | Pbfree Code | Part Status | Moisture Sensitivity Level (MSL) | Termination | ECCN Code | Connector Type | Max Operating Temperature | Min Operating Temperature | Color | Gender | HTS Code | Voltage - Rated DC | Orientation | Depth | Current Rating | Contact Finish | Wire Gauge | ELV | Wire Gauge (Max) | Wire Gauge (Min) | Body Plating | Wire/Cable Gauge | Sealable | Terminal and Terminal Block Type | Insulation Diameter | Insulation | Terminal Type | Plating - Body | Wire Cross Section | Mating Tab Width | Length - Tab | Features | Diameter | Length | Width | Length - Overall | Tab Thickness | Width - Tab | Radiation Hardening | RoHS Status | Lead Free |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() 0190030015 Molex | 11054 |
| Datasheet | 9 Weeks | - | - | Free Hanging | Free Hanging (In-Line) | - | Brass, Nylon | - | - | Brass | - | - | Tape & Reel (TR) | - | InsulKrimp | yes | Active | 1 (Unlimited) | Crimp | - | - | 105°C | -65°C | Salmon | Female | - | 600V | Straight | 8.03mm | - | Electro-Tin | 18-22 AWG | - | 22 AWG | 18 AWG | Tin | - | - | PUSH-ON TERMINAL | 0.230 (5.84mm) | Fully Insulated | Standard | - | - | - | - | - | - | 21.844mm | - | 0.860 21.84mm | 0.020 0.51mm | 0.187 4.75mm | - | ROHS3 Compliant | - | ||
![]() 94826 3M | 22 |
| Datasheet | 3 Weeks | - | - | Free Hanging | Free Hanging (In-Line) | - | - | 1.451496kg | - | Copper | Nylon | - | Bulk | 2002 | Highland™ | - | Active | 1 (Unlimited) | Crimp | - | - | - | - | Blue | Male | - | - | Straight | - | - | Tin | 14-16 AWG | - | 16 AWG | 14 AWG | - | -14 AWG | - | - | 0.170 (4.32mm) | Non-Mating End Insulated | Standard | - | - | - | - | Butted Seam | - | 23.876mm | 6.35mm | 0.940 23.88mm | 0.032 0.81mm | 0.250 6.35mm | - | RoHS Compliant | Lead Free | ||
![]() DV14-187B-M Panduit Corp | 16 |
| - | 4 Weeks | - | Tin | Free Hanging | Free Hanging (In-Line) | - | - | 703.068173g | - | Brass | Vinyl | - | Bulk | 2006 | Pan-Term® | - | Active | Not Applicable | Crimp | EAR99 | - | - | - | Blue | Female | 8536.90.40.00 | - | - | 5.8mm | - | - | 14-16 AWG | - | 16 AWG | 14 AWG | - | - | - | PUSH-ON TERMINAL | 0.170 (4.32mm) | Non-Mating End Insulated | Standard | - | 2.5 mm2 | - | - | Butted Seam | - | 19.05mm | 5.84mm | 0.750 19.05mm | 0.032 0.81mm | 0.187 4.75mm | No | ROHS3 Compliant | - | ||
![]() DNF18-250M-C Panduit Corp | 100 |
| - | 4 Weeks | - | Nickel | Free Hanging | Free Hanging (In-Line) | - | Brass | 127.005864g | - | Copper | Nylon | 600V | Bulk | 2005 | Pan-Term® | - | Active | Not Applicable | Crimp | - | INTERCONNECTION DEVICE | - | - | Red | Male | - | - | Straight | 6.4mm | - | - | 18-22 AWG | - | 18 AWG | 22 AWG | - | - | - | - | 0.138 (3.51mm) | Non-Mating End Insulated | Standard | - | - | - | - | Serrated Termination | - | 22.9mm | - | 0.900 22.86mm | 0.032 0.81mm | 0.250 6.35mm | No | ROHS3 Compliant | Lead Free | ||
Tiny WHSL | 6 |
| Datasheet | 3 Weeks | - | Tin | Free Hanging | Free Hanging (In-Line) | - | - | 521.631226g | Brass | Brass | - | - | Bulk | 2011 | Scotchlok™ | - | Active | 1 (Unlimited) | Crimp | - | - | - | - | - | Female | - | - | - | - | - | Tin | 18-22 AWG | - | 22 AWG | 18 AWG | Tin | - | - | - | - | Non-Insulated | Standard | - | - | - | - | Butted Seam | - | 14.732mm | - | 0.580 14.73mm | 0.020 0.51mm | 0.187 4.75mm | - | RoHS Compliant | - | ||
![]() 1544454-1 TE Connectivity | 175700 |
| Datasheet | 10 Weeks | ACTIVE (Last Updated: 4 days ago) | Tin | Free Hanging | - | - | Brass | - | Brass | Brass | - | - | Tape & Reel (TR) | 2009 | - | - | Active | - | Receptacle | - | - | - | - | - | Female | - | - | - | 7.5mm | - | - | - | Compliant | 13 AWG | 11 AWG | - | - | No | - | 4.699 mm | Non-Insulated | - | Tin | - | 6.35mm | 8.001mm | - | - | 20.4978mm | - | - | 812.8μm | 6.35mm | No | RoHS Compliant | Not Applicable | ||
![]() 3240060 Phoenix Contact | 25 |
| Datasheet | 4 Weeks | - | - | Free Hanging | Free Hanging (In-Line) | - | - | - | - | Brass | - | - | Bulk | 2011 | CLIPLINE | yes | Active | 1 (Unlimited) | Crimp | - | - | 105°C | -20°C | Yellow | Male | - | - | - | - | - | Tin | 10-12 AWG | - | 12 AWG | 10 AWG | - | - | - | TAB TERMINAL | - | Non-Mating End Insulated | Standard | - | - | - | - | - | - | 24.5mm | 6.3mm | 0.965 24.51mm | 0.032 0.81mm | 0.250 6.35mm | - | RoHS Compliant | - | ||
![]() 4918 Keystone Electronics | 8386 |
| Datasheet | 6 Weeks | - | - | Through Hole | Through Hole | - | - | - | - | Brass | - | - | Bulk | - | - | - | Active | 1 (Unlimited) | Solder | EAR99 | - | - | - | - | Male | 8536.90.40.00 | - | - | - | - | Tin | - | - | - | - | - | - | - | TAB TERMINAL | - | Non-Insulated | Angled | - | - | - | 0.217 5.50mm | - | - | - | - | - | 0.020 0.51mm | 0.187 4.75mm | - | ROHS3 Compliant | Lead Free | ||
![]() 0190060008 Molex | 780 |
| Datasheet | 4 Weeks | - | - | - | Free Hanging (In-Line), Right Angle | - | - | - | - | Brass | - | - | Bulk | - | Avikrimp | - | Active | 1 (Unlimited) | Crimp | - | - | - | - | Red | Female | - | - | - | - | - | - | 18-22 AWG | - | - | - | - | - | - | - | 0.150 (3.81mm) | Fully Insulated | Angled - 90°, Flag | - | - | - | - | - | - | - | - | - | 0.032 0.81mm | 0.187 4.75mm | - | ROHS3 Compliant | - | ||
![]() DNF14-250-E Panduit Corp | 116 |
| Datasheet | 4 Weeks | - | Tin | Free Hanging | Free Hanging (In-Line) | - | - | - | - | Copper | - | - | Bulk | 2009 | Pan-Term® | - | Active | Not Applicable | Crimp | - | - | - | - | Blue | Female | - | - | - | - | - | Tin | 14-16 AWG | - | 16 AWG | 14 AWG | - | - | - | - | 0.050 ~ 0.162 (1.27mm ~ 4.11mm) | Non-Mating End Insulated | Standard | - | - | - | - | Serrated Termination | - | 20.574mm | - | 0.810 20.57mm | 0.032 0.81mm | 0.250 6.35mm | No | ROHS3 Compliant | - | ||
![]() DV18-206B-3K Panduit Corp | 21299 |
| Datasheet | 4 Weeks | - | - | Free Hanging | Free Hanging (In-Line) | - | - | - | - | Brass | - | - | Tape & Reel (TR) | 2005 | Disco™ | - | Active | Not Applicable | Crimp | EAR99 | - | - | - | Red | Female | 8536.90.40.00 | - | - | - | - | Tin | 18-22 AWG | - | 22 AWG | 18 AWG | - | - | - | PUSH-ON TERMINAL | 0.150 (3.81mm) | Non-Mating End Insulated | Standard | - | 1.5 mm2 | - | - | Butted Seam, Serrated Termination | - | 19.558mm | - | 0.770 19.56mm | 0.020 0.51mm | 0.187 4.75mm 0.205 5.21mm | No | ROHS3 Compliant | - | ||
![]() DV10-250-E Panduit Corp | In Stock | - | - | 4 Weeks | - | Tin | Free Hanging | Free Hanging (In-Line) | - | - | - | - | Brass | - | - | Bulk | 2006 | Pan-Term® | - | Active | Not Applicable | Crimp | - | - | - | - | Yellow | Female | - | - | - | - | - | Tin | 10-12 AWG | - | 12 AWG | 10 AWG | - | - | - | - | 0.229 (5.82mm) | Non-Mating End Insulated | Standard | - | - | - | - | Serrated Termination | - | 26.162mm | - | 1.030 26.16mm | 0.032 0.81mm | 0.250 6.35mm | No | ROHS3 Compliant | - | ||
![]() 4005 Keystone Electronics | 644 |
| Datasheet | 6 Weeks | - | - | Chassis | Board, Chassis | - | - | - | - | Brass | Thermoplastic | - | Bulk | - | - | yes | Active | 1 (Unlimited) | Screw, Rivet, Stud | EAR99 | - | - | - | - | Male | 8536.90.40.00 | - | - | - | 15A | Tin | - | - | - | - | - | - | - | PCB TERMINAL | - | Non-Insulated | Angled - 45° | - | - | - | - | - | 1.778mm | 5.207mm | - | - | 0.020 0.51mm | 0.205 5.21mm | - | ROHS3 Compliant | Lead Free | ||
Tiny WHSL | 845 |
| Datasheet | 3 Weeks | - | Tin | Free Hanging | Free Hanging (In-Line) | - | - | 981.120296g | - | Brass | Nylon | - | Bulk | 2002 | Scotchlok™ | - | Active | 1 (Unlimited) | Crimp | - | - | - | - | Red | Female | - | - | - | 7.62mm | - | - | 18-22 AWG | - | 18 AWG | 22 AWG | - | - | - | - | 0.145 (3.68mm) | Fully Insulated | Standard | - | - | - | - | - | - | 20.574mm | - | 0.810 20.57mm | 0.020 0.51mm | 0.187 4.75mm | - | RoHS Compliant | - | ||
![]() DNF18-187-M Panduit Corp | In Stock | - | - | 4 Weeks | - | Tin | Free Hanging | Free Hanging (In-Line) | - | - | 997.903214g | - | Brass | Nylon | - | Bulk | 2005 | Pan-Term® | - | Active | Not Applicable | Crimp | EAR99 | - | - | - | Red | Female | 8536.90.40.00 | - | - | 5.8mm | - | - | 18-22 AWG | - | 18 AWG | 22 AWG | - | - | - | PUSH-ON TERMINAL | 0.137 (3.48mm) | Non-Mating End Insulated | Standard | - | - | - | - | Serrated Termination | - | 19.304mm | - | 0.760 19.30mm | 0.032 0.81mm | 0.187 4.75mm | No | ROHS3 Compliant | - | ||
![]() 94822 3M | In Stock | - | Datasheet | 3 Weeks | - | Tin | Free Hanging | Free Hanging (In-Line) | 100 | - | 816.466266g | - | Copper | Nylon | - | Bulk | 2002 | Highland™ | - | Obsolete | 1 (Unlimited) | Crimp | - | - | - | - | Blue | Male | - | - | Straight | - | - | Tin | 14-16 AWG | - | 16 AWG | 14 AWG | - | - | - | - | 0.145 (3.68mm) | Non-Mating End Insulated | Standard | - | - | - | - | Butted Seam | - | 21.336mm | 4.75mm | 0.840 21.34mm | 0.020 0.51mm | 0.187 4.75mm | - | RoHS Compliant | Lead Free | ||
![]() DNFR14-250B-M Panduit Corp | 495 |
| - | 4 Weeks | - | Tin | Free Hanging | Free Hanging (In-Line), Right Angle | - | - | 1.723651kg | - | Brass | Nylon | - | Bulk | 2011 | Pan-Term® | - | Active | Not Applicable | Crimp | EAR99 | - | - | - | Blue | Female | 8536.90.40.00 | - | - | 16mm | - | - | 14-16 AWG | - | 16 AWG | 14 AWG | - | - | - | PUSH-ON TERMINAL | 0.155 (3.94mm) | Fully Insulated | Angled - 90°, Flag | - | 2.5 mm2 | - | - | - | - | 20.066mm | - | - | 0.032 0.81mm | 0.250 6.35mm | No | ROHS3 Compliant | - | ||
![]() DPF18-250FIM-M Panduit Corp | 269 |
| - | 4 Weeks | - | Nickel | Free Hanging | Free Hanging (In-Line) | - | - | - | - | Brass | Nylon | - | Bulk | 2005 | DiscoGrip™ | - | Active | Not Applicable | Crimp | - | INTERCONNECTION DEVICE | - | - | Red | Male | - | - | - | 10.4mm | - | - | 18-22 AWG | - | 22 AWG | 18 AWG | - | - | - | - | 0.060 ~ 0.133 (1.52mm ~ 3.38mm) | Fully Insulated | Standard | - | - | - | - | - | - | 22.86mm | 10.4mm | 0.900 22.86mm | 0.032 0.81mm | 0.250 6.35mm | No | ROHS3 Compliant | - | ||
![]() DVF14-187-M Panduit Corp | In Stock | - | - | 4 Weeks | - | Tin | Free Hanging | Free Hanging (In-Line) | - | - | - | Copper | Brass | Vinyl | - | Bulk | 2005 | Pan-Term® | - | Obsolete | Not Applicable | Crimp | - | - | - | - | Blue | Female | - | - | - | 5.8mm | - | - | 14-16 AWG | - | 16 AWG | 14 AWG | - | - | - | PUSH-ON TERMINAL | 0.162 (4.11mm) | Non-Mating End Insulated | Standard | - | - | - | - | - | - | 19.304mm | 5.84mm | 0.760 19.30mm | 0.032 0.81mm | 0.187 4.75mm | No | ROHS3 Compliant | - | ||
![]() DPF10-250FIB-L Panduit Corp | 7 |
| Datasheet | 4 Weeks | - | - | Free Hanging | Free Hanging (In-Line) | - | - | 88.450512g | - | Brass | Nylon | - | Bulk | 2001 | DiscoGrip™ | - | Active | Not Applicable | Crimp | EAR99 | - | - | - | Yellow | Female | 8536.90.40.00 | - | - | - | - | Tin | 10-12 AWG | - | 12 AWG | 10 AWG | - | - | - | PUSH-ON TERMINAL | 0.140 ~ 0.220 (3.56mm ~ 5.59mm) | Fully Insulated | Standard | - | 6 mm2 | - | - | - | - | 24.384mm | 8.89mm | 0.960 24.38mm | 0.032 0.81mm | 0.250 6.35mm | No | ROHS3 Compliant | - |