Filters
  • Manufacturer
    • TE Connectivity
    • Molex
    • Panduit
    • 3M
    • Lapp
    • NTE ELECT
    • Keystone Electronics Corp
    • Greenlee Klauke
    • Phoenix Contact
    • Wurth Electronics
    • AMP
    • JST
    • Master Appliance
    • Remington
    • Brady Corporation
    • HEYCO PRODUCTS
    • interlight
    • Littelfuse
    • Weidmuller
    • Texas Instruments
    • Harwin
    • RS Pro
    • ABB
    • Adafruit
    • Greenlee
    • Desco
    • Raychem
    • Amphenol
    • Eaton
    • Cooper Bussmann
    • Multicomp
    • Wiha
    • Advanced
    • Schneider
    • EAO
    • Honeywell
    • SMC Corporation
    • SparkFun
    • C&K
    • Cooper
    • Finder
    • FLUKE
    • FLUKE Pomona
    • HellermannTyton
    • National Semiconductor
    • Norgren
    • Ohmite
    • Panasonic
    • Rockwell
    • Schurter
    • SK Hand Tool
    • STMicroelectronics
    • Elesa USA Corporation
    • Abracon
    • Alpha and Omega
    • Altech
    • Apex Tool Group
    • Astro Tool
    • Belden
    • Cypress
    • EMC
    • Fairchild
    • Glenair
    • Klein Tools
    • Lantronix
    • Lumberg Automation
    • Menda
    • Mitutoyo
    • Murata
    • Omron
    • PIC GmbH
    • Radiall
    • SICK
    • Visual
    • Wakefield
    • WECO
  • Gender
  • Insulation
  • RoHS Status
  • Termination
  • Width - Tab
  • Tab Thickness
  • Factory Lead Time
  • Packaging
  • Part Status
  • Length
  • Mount
  • Contact Materials

Attribute column

Categories

Terminals - Quick Connects, Quick Disconnect Connectors

View Mode:
5946 Results

Product

Inventory

Pricing(USD)

Quantity

Datasheet

RoHS

Factory Lead Time

Lifecycle Status

Contact Plating

Mount

Mounting Type

Package / Case

Material

Weight

Body Material

Contact Materials

Insulation Materials

Voltage Rated

Packaging

Published

Series

Pbfree Code

Part Status

Moisture Sensitivity Level (MSL)

Termination

ECCN Code

Connector Type

Max Operating Temperature

Min Operating Temperature

Color

Gender

HTS Code

Voltage - Rated DC

Orientation

Depth

Current Rating

Contact Finish

Wire Gauge

ELV

Wire Gauge (Max)

Wire Gauge (Min)

Body Plating

Wire/Cable Gauge

Sealable

Terminal and Terminal Block Type

Insulation Diameter

Insulation

Terminal Type

Plating - Body

Wire Cross Section

Mating Tab Width

Length - Tab

Features

Diameter

Length

Width

Length - Overall

Tab Thickness

Width - Tab

Radiation Hardening

RoHS Status

Lead Free

11054
Datasheet

9 Weeks

-

-

Free Hanging

Free Hanging (In-Line)

-

Brass, Nylon

-

-

Brass

-

-

Tape & Reel (TR)

-

InsulKrimp

yes

Active

1 (Unlimited)

Crimp

-

-

105°C

-65°C

Salmon

Female

-

600V

Straight

8.03mm

-

Electro-Tin

18-22 AWG

-

22 AWG

18 AWG

Tin

-

-

PUSH-ON TERMINAL

0.230 (5.84mm)

Fully Insulated

Standard

-

-

-

-

-

-

21.844mm

-

0.860 21.84mm

0.020 0.51mm

0.187 4.75mm

-

ROHS3 Compliant

-

22
Datasheet

3 Weeks

-

-

Free Hanging

Free Hanging (In-Line)

-

-

1.451496kg

-

Copper

Nylon

-

Bulk

2002

Highland™

-

Active

1 (Unlimited)

Crimp

-

-

-

-

Blue

Male

-

-

Straight

-

-

Tin

14-16 AWG

-

16 AWG

14 AWG

-

-14 AWG

-

-

0.170 (4.32mm)

Non-Mating End Insulated

Standard

-

-

-

-

Butted Seam

-

23.876mm

6.35mm

0.940 23.88mm

0.032 0.81mm

0.250 6.35mm

-

RoHS Compliant

Lead Free

DV14-187B-M
DV14-187B-M

Panduit Corp

16
-

4 Weeks

-

Tin

Free Hanging

Free Hanging (In-Line)

-

-

703.068173g

-

Brass

Vinyl

-

Bulk

2006

Pan-Term®

-

Active

Not Applicable

Crimp

EAR99

-

-

-

Blue

Female

8536.90.40.00

-

-

5.8mm

-

-

14-16 AWG

-

16 AWG

14 AWG

-

-

-

PUSH-ON TERMINAL

0.170 (4.32mm)

Non-Mating End Insulated

Standard

-

2.5 mm2

-

-

Butted Seam

-

19.05mm

5.84mm

0.750 19.05mm

0.032 0.81mm

0.187 4.75mm

No

ROHS3 Compliant

-

DNF18-250M-C
DNF18-250M-C

Panduit Corp

100
-

4 Weeks

-

Nickel

Free Hanging

Free Hanging (In-Line)

-

Brass

127.005864g

-

Copper

Nylon

600V

Bulk

2005

Pan-Term®

-

Active

Not Applicable

Crimp

-

INTERCONNECTION DEVICE

-

-

Red

Male

-

-

Straight

6.4mm

-

-

18-22 AWG

-

18 AWG

22 AWG

-

-

-

-

0.138 (3.51mm)

Non-Mating End Insulated

Standard

-

-

-

-

Serrated Termination

-

22.9mm

-

0.900 22.86mm

0.032 0.81mm

0.250 6.35mm

No

ROHS3 Compliant

Lead Free

6
Datasheet

3 Weeks

-

Tin

Free Hanging

Free Hanging (In-Line)

-

-

521.631226g

Brass

Brass

-

-

Bulk

2011

Scotchlok™

-

Active

1 (Unlimited)

Crimp

-

-

-

-

-

Female

-

-

-

-

-

Tin

18-22 AWG

-

22 AWG

18 AWG

Tin

-

-

-

-

Non-Insulated

Standard

-

-

-

-

Butted Seam

-

14.732mm

-

0.580 14.73mm

0.020 0.51mm

0.187 4.75mm

-

RoHS Compliant

-

1544454-1
1544454-1

TE Connectivity

175700
Datasheet

10 Weeks

ACTIVE (Last Updated: 4 days ago)

Tin

Free Hanging

-

-

Brass

-

Brass

Brass

-

-

Tape & Reel (TR)

2009

-

-

Active

-

Receptacle

-

-

-

-

-

Female

-

-

-

7.5mm

-

-

-

Compliant

13 AWG

11 AWG

-

-

No

-

4.699 mm

Non-Insulated

-

Tin

-

6.35mm

8.001mm

-

-

20.4978mm

-

-

812.8μm

6.35mm

No

RoHS Compliant

Not Applicable

3240060
3240060

Phoenix Contact

25
Datasheet

4 Weeks

-

-

Free Hanging

Free Hanging (In-Line)

-

-

-

-

Brass

-

-

Bulk

2011

CLIPLINE

yes

Active

1 (Unlimited)

Crimp

-

-

105°C

-20°C

Yellow

Male

-

-

-

-

-

Tin

10-12 AWG

-

12 AWG

10 AWG

-

-

-

TAB TERMINAL

-

Non-Mating End Insulated

Standard

-

-

-

-

-

-

24.5mm

6.3mm

0.965 24.51mm

0.032 0.81mm

0.250 6.35mm

-

RoHS Compliant

-

4918
4918

Keystone Electronics

8386
Datasheet

6 Weeks

-

-

Through Hole

Through Hole

-

-

-

-

Brass

-

-

Bulk

-

-

-

Active

1 (Unlimited)

Solder

EAR99

-

-

-

-

Male

8536.90.40.00

-

-

-

-

Tin

-

-

-

-

-

-

-

TAB TERMINAL

-

Non-Insulated

Angled

-

-

-

0.217 5.50mm

-

-

-

-

-

0.020 0.51mm

0.187 4.75mm

-

ROHS3 Compliant

Lead Free

780
Datasheet

4 Weeks

-

-

-

Free Hanging (In-Line), Right Angle

-

-

-

-

Brass

-

-

Bulk

-

Avikrimp

-

Active

1 (Unlimited)

Crimp

-

-

-

-

Red

Female

-

-

-

-

-

-

18-22 AWG

-

-

-

-

-

-

-

0.150 (3.81mm)

Fully Insulated

Angled - 90°, Flag

-

-

-

-

-

-

-

-

-

0.032 0.81mm

0.187 4.75mm

-

ROHS3 Compliant

-

DNF14-250-E
DNF14-250-E

Panduit Corp

116
Datasheet

4 Weeks

-

Tin

Free Hanging

Free Hanging (In-Line)

-

-

-

-

Copper

-

-

Bulk

2009

Pan-Term®

-

Active

Not Applicable

Crimp

-

-

-

-

Blue

Female

-

-

-

-

-

Tin

14-16 AWG

-

16 AWG

14 AWG

-

-

-

-

0.050 ~ 0.162 (1.27mm ~ 4.11mm)

Non-Mating End Insulated

Standard

-

-

-

-

Serrated Termination

-

20.574mm

-

0.810 20.57mm

0.032 0.81mm

0.250 6.35mm

No

ROHS3 Compliant

-

DV18-206B-3K
DV18-206B-3K

Panduit Corp

21299
Datasheet

4 Weeks

-

-

Free Hanging

Free Hanging (In-Line)

-

-

-

-

Brass

-

-

Tape & Reel (TR)

2005

Disco™

-

Active

Not Applicable

Crimp

EAR99

-

-

-

Red

Female

8536.90.40.00

-

-

-

-

Tin

18-22 AWG

-

22 AWG

18 AWG

-

-

-

PUSH-ON TERMINAL

0.150 (3.81mm)

Non-Mating End Insulated

Standard

-

1.5 mm2

-

-

Butted Seam, Serrated Termination

-

19.558mm

-

0.770 19.56mm

0.020 0.51mm

0.187 4.75mm 0.205 5.21mm

No

ROHS3 Compliant

-

DV10-250-E
DV10-250-E

Panduit Corp

In Stock

-

-

4 Weeks

-

Tin

Free Hanging

Free Hanging (In-Line)

-

-

-

-

Brass

-

-

Bulk

2006

Pan-Term®

-

Active

Not Applicable

Crimp

-

-

-

-

Yellow

Female

-

-

-

-

-

Tin

10-12 AWG

-

12 AWG

10 AWG

-

-

-

-

0.229 (5.82mm)

Non-Mating End Insulated

Standard

-

-

-

-

Serrated Termination

-

26.162mm

-

1.030 26.16mm

0.032 0.81mm

0.250 6.35mm

No

ROHS3 Compliant

-

4005
4005

Keystone Electronics

644
Datasheet

6 Weeks

-

-

Chassis

Board, Chassis

-

-

-

-

Brass

Thermoplastic

-

Bulk

-

-

yes

Active

1 (Unlimited)

Screw, Rivet, Stud

EAR99

-

-

-

-

Male

8536.90.40.00

-

-

-

15A

Tin

-

-

-

-

-

-

-

PCB TERMINAL

-

Non-Insulated

Angled - 45°

-

-

-

-

-

1.778mm

5.207mm

-

-

0.020 0.51mm

0.205 5.21mm

-

ROHS3 Compliant

Lead Free

845
Datasheet

3 Weeks

-

Tin

Free Hanging

Free Hanging (In-Line)

-

-

981.120296g

-

Brass

Nylon

-

Bulk

2002

Scotchlok™

-

Active

1 (Unlimited)

Crimp

-

-

-

-

Red

Female

-

-

-

7.62mm

-

-

18-22 AWG

-

18 AWG

22 AWG

-

-

-

-

0.145 (3.68mm)

Fully Insulated

Standard

-

-

-

-

-

-

20.574mm

-

0.810 20.57mm

0.020 0.51mm

0.187 4.75mm

-

RoHS Compliant

-

DNF18-187-M
DNF18-187-M

Panduit Corp

In Stock

-

-

4 Weeks

-

Tin

Free Hanging

Free Hanging (In-Line)

-

-

997.903214g

-

Brass

Nylon

-

Bulk

2005

Pan-Term®

-

Active

Not Applicable

Crimp

EAR99

-

-

-

Red

Female

8536.90.40.00

-

-

5.8mm

-

-

18-22 AWG

-

18 AWG

22 AWG

-

-

-

PUSH-ON TERMINAL

0.137 (3.48mm)

Non-Mating End Insulated

Standard

-

-

-

-

Serrated Termination

-

19.304mm

-

0.760 19.30mm

0.032 0.81mm

0.187 4.75mm

No

ROHS3 Compliant

-

In Stock

-

Datasheet

3 Weeks

-

Tin

Free Hanging

Free Hanging (In-Line)

100

-

816.466266g

-

Copper

Nylon

-

Bulk

2002

Highland™

-

Obsolete

1 (Unlimited)

Crimp

-

-

-

-

Blue

Male

-

-

Straight

-

-

Tin

14-16 AWG

-

16 AWG

14 AWG

-

-

-

-

0.145 (3.68mm)

Non-Mating End Insulated

Standard

-

-

-

-

Butted Seam

-

21.336mm

4.75mm

0.840 21.34mm

0.020 0.51mm

0.187 4.75mm

-

RoHS Compliant

Lead Free

DNFR14-250B-M
DNFR14-250B-M

Panduit Corp

495
-

4 Weeks

-

Tin

Free Hanging

Free Hanging (In-Line), Right Angle

-

-

1.723651kg

-

Brass

Nylon

-

Bulk

2011

Pan-Term®

-

Active

Not Applicable

Crimp

EAR99

-

-

-

Blue

Female

8536.90.40.00

-

-

16mm

-

-

14-16 AWG

-

16 AWG

14 AWG

-

-

-

PUSH-ON TERMINAL

0.155 (3.94mm)

Fully Insulated

Angled - 90°, Flag

-

2.5 mm2

-

-

-

-

20.066mm

-

-

0.032 0.81mm

0.250 6.35mm

No

ROHS3 Compliant

-

DPF18-250FIM-M
DPF18-250FIM-M

Panduit Corp

269
-

4 Weeks

-

Nickel

Free Hanging

Free Hanging (In-Line)

-

-

-

-

Brass

Nylon

-

Bulk

2005

DiscoGrip™

-

Active

Not Applicable

Crimp

-

INTERCONNECTION DEVICE

-

-

Red

Male

-

-

-

10.4mm

-

-

18-22 AWG

-

22 AWG

18 AWG

-

-

-

-

0.060 ~ 0.133 (1.52mm ~ 3.38mm)

Fully Insulated

Standard

-

-

-

-

-

-

22.86mm

10.4mm

0.900 22.86mm

0.032 0.81mm

0.250 6.35mm

No

ROHS3 Compliant

-

DVF14-187-M
DVF14-187-M

Panduit Corp

In Stock

-

-

4 Weeks

-

Tin

Free Hanging

Free Hanging (In-Line)

-

-

-

Copper

Brass

Vinyl

-

Bulk

2005

Pan-Term®

-

Obsolete

Not Applicable

Crimp

-

-

-

-

Blue

Female

-

-

-

5.8mm

-

-

14-16 AWG

-

16 AWG

14 AWG

-

-

-

PUSH-ON TERMINAL

0.162 (4.11mm)

Non-Mating End Insulated

Standard

-

-

-

-

-

-

19.304mm

5.84mm

0.760 19.30mm

0.032 0.81mm

0.187 4.75mm

No

ROHS3 Compliant

-

DPF10-250FIB-L
DPF10-250FIB-L

Panduit Corp

7
Datasheet

4 Weeks

-

-

Free Hanging

Free Hanging (In-Line)

-

-

88.450512g

-

Brass

Nylon

-

Bulk

2001

DiscoGrip™

-

Active

Not Applicable

Crimp

EAR99

-

-

-

Yellow

Female

8536.90.40.00

-

-

-

-

Tin

10-12 AWG

-

12 AWG

10 AWG

-

-

-

PUSH-ON TERMINAL

0.140 ~ 0.220 (3.56mm ~ 5.59mm)

Fully Insulated

Standard

-

6 mm2

-

-

-

-

24.384mm

8.89mm

0.960 24.38mm

0.032 0.81mm

0.250 6.35mm

No

ROHS3 Compliant

-