Filters
  • Manufacturer
    • TE Connectivity
    • Molex
    • Panduit
    • 3M
    • Lapp
    • NTE ELECT
    • Keystone Electronics Corp
    • Greenlee Klauke
    • Phoenix Contact
    • Wurth Electronics
    • AMP
    • JST
    • Master Appliance
    • Remington
    • Brady Corporation
    • HEYCO PRODUCTS
    • interlight
    • Littelfuse
    • Weidmuller
    • Texas Instruments
    • Harwin
    • RS Pro
    • ABB
    • Adafruit
    • Greenlee
    • Desco
    • Raychem
    • Amphenol
    • Eaton
    • Cooper Bussmann
    • Multicomp
    • Wiha
    • Advanced
    • Schneider
    • EAO
    • Honeywell
    • SMC Corporation
    • SparkFun
    • C&K
    • Cooper
    • Finder
    • FLUKE
    • FLUKE Pomona
    • HellermannTyton
    • National Semiconductor
    • Norgren
    • Ohmite
    • Panasonic
    • Rockwell
    • Schurter
    • SK Hand Tool
    • STMicroelectronics
    • Elesa USA Corporation
    • Abracon
    • Alpha and Omega
    • Altech
    • Apex Tool Group
    • Astro Tool
    • Belden
    • Cypress
    • EMC
    • Fairchild
    • Glenair
    • Klein Tools
    • Lantronix
    • Lumberg Automation
    • Menda
    • Mitutoyo
    • Murata
    • Omron
    • PIC GmbH
    • Radiall
    • SICK
    • Visual
    • Wakefield
    • WECO
  • Gender
  • Insulation
  • RoHS Status
  • Termination
  • Width - Tab
  • Tab Thickness
  • Factory Lead Time
  • Packaging
  • Part Status
  • Length
  • Mount
  • Contact Materials

Attribute column

Categories

Terminals - Quick Connects, Quick Disconnect Connectors

View Mode:
5946 Results

Product

Inventory

Pricing(USD)

Quantity

Datasheet

RoHS

Factory Lead Time

Lifecycle Status

Contact Plating

Mount

Mounting Type

Package / Case

Number of Pins

Material

Weight

Body Material

Terminal Material

Contact Materials

Insulation Materials

Packaging

Published

Series

Pbfree Code

Part Status

Moisture Sensitivity Level (MSL)

Termination

ECCN Code

Connector Type

Number of Positions

Max Operating Temperature

Min Operating Temperature

Color

Gender

HTS Code

Orientation

Shielding

Depth

Current Rating

Contact Finish

Approval Agency

Number of Contacts

Wire Gauge

ELV

Wire Gauge (Max)

Wire Gauge (Min)

Body Plating

Wire/Cable Gauge

Sealable

Terminal and Terminal Block Type

Insulation Diameter

Insulation

Terminal Type

Wire Cross Section

Mating Tab Width

Stud Diameter

Length - Tab

Features

Diameter

Length

Width

Length - Overall

Diameter - Inside

Tab Thickness

Width - Tab

Radiation Hardening

REACH SVHC

RoHS Status

Lead Free

344009-1
344009-1

TE Connectivity

9000

-

Datasheet

13 Weeks

ACTIVE (Last Updated: 4 months ago)

Tin

Cable, Free Hanging

-

-

-

-

-

-

-

Brass

-

Tape & Reel (TR)

2005

-

-

Active

-

Crimp

EAR99

Connector, PCB, Signal

-

-

-

-

Receptacle

8536.90.40.00

Straight

Unshielded

-

-

-

-

-

-

Compliant

14 AWG

12 AWG

-

12 AWG

Yes

PUSH-ON TERMINAL

3.4 mm

Non-Insulated

-

3 mm2

6.2992mm

-

7.747mm

-

-

19.7104mm

-

-

-

812.8μm

6.35mm

-

Unknown

RoHS Compliant

Not Applicable

DNF18250FIBX-L
DNF18250FIBX-L

Panduit Corp

85676
Datasheet

4 Weeks

-

Tin

Free Hanging

Free Hanging (In-Line)

-

-

-

-

Copper

-

Brass

-

Bulk

2011

Pan-Term®

-

Active

Not Applicable

Crimp

EAR99

-

-

-

-

Red

Female

8536.90.40.00

-

-

8.9mm

-

-

-

-

18-22 AWG

-

22 AWG

18 AWG

-

-

-

PUSH-ON TERMINAL

0.210 (5.33mm)

Fully Insulated

Standard

-

-

-

-

Butted Seam

-

23.622mm

-

0.930 23.62mm

-

0.032 0.81mm

0.250 6.35mm

No

-

ROHS3 Compliant

-

8272
8272

Keystone Electronics

641
Datasheet

6 Weeks

-

-

Free Hanging

Free Hanging (In-Line)

-

-

-

-

-

-

Copper

-

Bulk

-

-

-

Active

1 (Unlimited)

Crimp

EAR99

-

-

-

-

-

Female

8536.90.40.00

Straight

-

-

-

Tin

-

-

18-22 AWG

-

22 AWG

18 AWG

-

-

-

PUSH-ON TERMINAL

-

Non-Insulated

Standard

-

-

-

-

-

2.159mm

14.732mm

4.75mm

0.580 14.73mm

-

0.020 0.51mm

0.187 4.75mm

-

-

ROHS3 Compliant

Lead Free

8275
8275

Keystone Electronics

45
Datasheet

6 Weeks

-

-

Free Hanging

Free Hanging (In-Line)

-

-

-

-

-

-

Copper

-

Bulk

-

-

-

Active

1 (Unlimited)

Crimp

EAR99

-

-

-

-

-

Female

8536.90.40.00

Straight

-

-

-

Tin

-

-

14-16 AWG

-

16 AWG

14 AWG

-

-

-

PUSH-ON TERMINAL

-

Non-Insulated

Standard

-

-

-

-

-

-

16.764mm

6.35mm

0.660 16.76mm

-

0.032 0.81mm

0.250 6.35mm

-

-

ROHS3 Compliant

-

1713
Datasheet

-

-

Tin

Free Hanging

Free Hanging (In-Line)

-

-

-

-

-

-

Brass

-

Cut Tape (CT)

-

InsulKrimp

yes

Discontinued

1 (Unlimited)

Crimp

EAR99

-

-

-

-

Blue

Female and Male

8536.90.40.00

Straight

-

6.35mm

-

-

-

-

14-16 AWG

-

16 AWG

14 AWG

-

-

-

PUSH-ON TERMINAL

0.140 (3.56mm)

Non-Mating End Insulated

Stacked

-

-

-

0.310 7.87mm

-

-

22.098mm

-

0.870 22.10mm

-

0.032 0.81mm

0.250 6.35mm

No

-

ROHS3 Compliant

-

7814
7814

Keystone Electronics

75
Datasheet

6 Weeks

-

-

Through Hole

Through Hole

-

4

-

-

-

-

Brass

Thermoplastic

Bulk

-

-

yes

Active

1 (Unlimited)

Solder

-

INTERCONNECTION DEVICE

-

-

-

Black

Male

-

Straight

-

-

15A

Tin

-

-

-

-

-

-

-

-

-

-

-

Non-Mating End Insulated

Header

-

-

-

0.307 7.80mm

4 Tabs

-

24.9936mm

-

0.984 25.00mm

-

0.032 0.81mm

0.250 6.35mm

-

-

ROHS3 Compliant

Lead Free

2004
2004

Keystone Electronics

1294
Datasheet

6 Weeks

-

-

Chassis

Board, Chassis

-

-

-

-

-

-

Brass

-

Bulk

-

-

yes

Active

1 (Unlimited)

Screw, Rivet, Stud

EAR99

-

-

-

-

-

Male

8536.90.40.00

-

-

-

-

-

-

-

-

-

-

-

-

-

-

PCB TERMINAL

-

Non-Insulated

Angled - 45°

-

-

-

-

-

-

4.57mm

-

-

-

0.020 0.51mm

0.110 2.79mm

-

-

ROHS3 Compliant

Lead Free

141879-2
141879-2

TE Connectivity AMP Connectors

In Stock

-

-

19 Weeks

ACTIVE (Last Updated: 2 days ago)

Tin

Chassis

Board, Chassis

-

-

-

-

-

-

Brass

-

Bulk

2006

Faston

yes

Active

1 (Unlimited)

Screw, Rivet, Stud

EAR99

-

-

-

-

-

Male

8536.90.40.00

Right Angle

-

8mm

-

-

-

-

-

Compliant

-

-

-

-

-

WIRE TERMINAL

-

Non-Insulated

Angled - 90°

-

6.35mm

4.0894 mm

0.311 7.90mm

-

-

10.3mm

-

-

-

0.032 0.81mm

0.250 6.35mm

No

No SVHC

RoHS Compliant

-

DV14-250B-E
DV14-250B-E

Panduit Corp

47
Datasheet

4 Weeks

-

-

Free Hanging

Free Hanging (In-Line)

-

-

-

-

-

-

Brass

-

Bulk

2011

Pan-Term®

yes

Active

Not Applicable

Crimp

-

-

-

-

-

Blue

Female

-

-

-

-

-

Tin

-

-

14-16 AWG

-

16 AWG

14 AWG

-

-

-

PUSH-ON TERMINAL

0.170 (4.32mm)

Non-Mating End Insulated

Standard

-

-

-

-

Butted Seam, Serrated Termination

-

20.574mm

-

0.810 20.57mm

-

0.032 0.81mm

0.250 6.35mm

No

-

ROHS3 Compliant

-

1281
1281

Keystone Electronics

18678
Datasheet

6 Weeks

-

-

Through Hole, Vertical

Through Hole

-

-

-

-

-

-

Brass

-

Bulk

-

-

yes

Active

1 (Unlimited)

Solder

EAR99

-

1

-

-

-

Male

-

Straight

-

-

-

Tin

-

-

-

-

-

-

-

-

-

TAB TERMINAL

-

Non-Insulated

Standard

-

-

-

0.312 7.92mm

-

1.3208mm

30.988mm

-

1.220 30.99mm

1.78 mm

0.032 0.81mm

0.250 6.35mm

-

No SVHC

ROHS3 Compliant

Lead Free

1544545-1
1544545-1

TE Connectivity

90
Datasheet

26 Weeks

-

-

-

-

-

-

Brass

-

Brass

Brass

Brass

-

-

2004

-

-

Active

-

Receptacle

-

Tab

-

-

-

-

Receptacle

-

-

-

4mm

-

-

IEC

-

-

Compliant

17 AWG

24 AWG

-

24 AWG

-

-

-

Non-Insulated

-

-

-

-

-

-

-

14mm

-

-

-

-

-

No

Unknown

RoHS Compliant

Not Applicable

303
Datasheet

6 Weeks

-

Tin

Free Hanging

Free Hanging (In-Line)

-

-

Brass

-

Brass

-

Brass

-

Bulk

-

Krimptite

-

Active

1 (Unlimited)

Crimp

-

-

-

-

-

-

Female

-

Straight

-

6mm

-

Electro-Tin

-

-

18-22 AWG

-

22 AWG

18 AWG

Tin

-

-

-

-

Non-Insulated

Standard

-

-

-

0.250 6.35mm

-

-

14.732mm

-

0.580 14.73mm

-

0.032 0.81mm

0.187 4.75mm

-

-

ROHS3 Compliant

-

DNF18-187FIB-M
DNF18-187FIB-M

Panduit Corp

93000
Datasheet

4 Weeks

-

Tin

Free Hanging

Free Hanging (In-Line)

-

-

-

907.18474g

-

-

Brass

Nylon

Bulk

2009

Pan-Term®

-

Active

Not Applicable

Crimp

EAR99

-

-

-

-

Red

Female

8536.90.40.00

-

-

7.4mm

-

-

-

-

18-22 AWG

-

22 AWG

18 AWG

-

-

-

PUSH-ON TERMINAL

0.136 (3.45mm)

Fully Insulated

Standard

1.5 mm2

-

-

-

Serrated Termination

-

19.8mm

-

0.780 19.81mm

-

0.032 0.81mm

0.187 4.75mm

No

-

ROHS3 Compliant

-

1213-ST
1213-ST

Keystone Electronics

4421
Datasheet

6 Weeks

-

-

Through Hole

Through Hole

052

-

-

-

-

-

Brass

-

Bulk

2012

-

-

Active

1 (Unlimited)

Solder

EAR99

-

1

-

-

-

Male

8536.90.40.00

Straight

-

-

-

Tin

-

2

-

-

-

-

-

-

-

TAB TERMINAL

-

Non-Insulated

Standard

-

-

-

0.250 6.35mm

-

-

12.954mm

7.14mm

0.510 12.95mm

1.78 mm

0.032 0.81mm

0.205 5.21mm

-

-

ROHS3 Compliant

Lead Free

DNF14-250-M
DNF14-250-M

Panduit Corp

1455

-

-

4 Weeks

-

-

Free Hanging

Free Hanging (In-Line)

-

-

Brass

1.360777kg

-

-

Copper

Nylon

Bulk

2005

Pan-Term®

-

Active

Not Applicable

Crimp

EAR99

-

-

-

-

Blue

Female

8536.90.40.00

Straight

-

-

-

Tin

-

-

14-16 AWG

-

14 AWG

16 AWG

-

-

-

PUSH-ON TERMINAL

0.050 ~ 0.162 (1.27mm ~ 4.11mm)

Non-Mating End Insulated

Standard

-

-

-

-

Serrated Termination

-

21.082mm

7.37mm

0.830 21.08mm

-

0.032 0.81mm

0.250 6.35mm

No

-

ROHS3 Compliant

-

DNFR14-206B-L
DNFR14-206B-L

Panduit Corp

16
-

4 Weeks

-

Tin

Free Hanging

Free Hanging (In-Line), Right Angle

-

-

-

99.790321g

-

-

Brass

Nylon

Bulk

2011

Pan-Term®

-

Active

Not Applicable

Crimp

EAR99

-

-

-

-

Blue

Female

8536.90.40.00

-

-

9.1mm

-

-

-

-

14-16 AWG

-

14 AWG

16 AWG

-

-

-

PUSH-ON TERMINAL

0.155 (3.94mm)

Fully Insulated

Angled - 90°, Flag

2.5 mm2

-

-

-

Butted Seam

-

19.8mm

-

-

-

0.020 0.51mm

0.187 4.75mm 0.205 5.21mm

No

-

ROHS3 Compliant

-

DNF18-188FIB-M
DNF18-188FIB-M

Panduit Corp

276000
Datasheet

4 Weeks

-

Tin

Free Hanging

Free Hanging (In-Line)

-

-

-

-

-

-

Brass

Nylon

Bulk

2007

Pan-Term®

-

Active

Not Applicable

Crimp

EAR99

-

-

-

-

Red

Female

8536.90.40.00

-

-

7.4mm

-

-

-

-

18-22 AWG

-

22 AWG

18 AWG

-

-

-

PUSH-ON TERMINAL

0.136 (3.45mm)

Fully Insulated

Standard

1.5 mm2

-

-

-

Serrated Termination

-

19.812mm

7.37mm

0.780 19.81mm

-

0.020 0.51mm

0.187 4.75mm

No

-

ROHS3 Compliant

-

DNH14-250FIB-Q
DNH14-250FIB-Q

Panduit Corp

In Stock

-

Datasheet

4 Weeks

-

Tin

Free Hanging

Free Hanging (In-Line)

-

-

-

-

-

-

Brass

Nylon

Bulk

2005

Pan-Term®

-

Active

Not Applicable

Crimp

EAR99

-

-

110°C

-55°C

Blue

Female

8536.90.40.00

-

-

8.9mm

-

-

-

-

14-16 AWG

-

16 AWG

14 AWG

-

-

-

PUSH-ON TERMINAL

0.156 (3.96mm)

Fully Insulated Heat Shrink

Standard

-

-

-

-

-

-

36.576mm

8.89mm

1.440 36.58mm

-

0.032 0.81mm

0.250 6.35mm

No

-

ROHS3 Compliant

-

D10-250-D
D10-250-D

Panduit Corp

3160
Datasheet

4 Weeks

-

Tin

Free Hanging

Free Hanging (In-Line)

-

-

-

771.107029g

-

-

Brass

-

Bulk

2001

Pan-Term®

-

Active

Not Applicable

Crimp

-

INTERCONNECTION DEVICE

-

-

-

-

Female

-

-

-

7.62mm

-

-

-

-

10-12 AWG

-

18 AWG

22 AWG

-

-

-

-

-

Non-Insulated

Standard

-

-

-

-

Serrated Termination

-

16.764mm

7.62mm

0.660 16.76mm

-

0.032 0.81mm

0.250 6.35mm

No

-

ROHS3 Compliant

-

154897-2
154897-2

TE Connectivity AMP Connectors

In Stock

-

Datasheet

15 Weeks

ACTIVE (Last Updated: 4 days ago)

Tin

Free Hanging

Free Hanging (In-Line), Right Angle

-

-

-

-

-

-

Brass

-

Reel

1998

Faston

yes

Active

1 (Unlimited)

Crimp

EAR99

-

-

-

-

-

Female

8536.90.40.00

-

-

-

-

-

-

-

10-12 AWG

Compliant

12 AWG

10 AWG

-

-

No

PUSH-ON TERMINAL

0.135 ~ 0.234 (3.43mm ~ 5.94mm)

Non-Insulated

Angled - 90°, Flag

6 mm2

9.53mm

-

-

-

-

21.0058mm

-

-

-

0.047 1.19mm

0.375 9.53mm

-

-

RoHS Compliant

Not Applicable