- Manufacturer
- Gender
- Insulation
- RoHS Status
- Termination
- Width - Tab
- Tab Thickness
- Factory Lead Time
- Packaging
- Part Status
- Length
- Mount
- Contact Materials
Attribute column
Categories
Terminals - Quick Connects, Quick Disconnect Connectors
Product | Inventory | Pricing(USD) | Quantity | Datasheet | RoHS | Factory Lead Time | Lifecycle Status | Contact Plating | Mount | Mounting Type | Material | Weight | Contact Materials | Insulation Materials | Voltage Rated | Packaging | Published | Series | Pbfree Code | Part Status | Moisture Sensitivity Level (MSL) | Termination | ECCN Code | Connector Type | Max Operating Temperature | Min Operating Temperature | Color | Gender | HTS Code | Orientation | Depth | Reach Compliance Code | Contact Finish | Wire Gauge | ELV | Wire Gauge (Max) | Wire Gauge (Min) | Wire/Cable Gauge | Sealable | Terminal and Terminal Block Type | Halogen Free | Insulation Diameter | Insulation | Terminal Type | Plating - Body | Wire Cross Section | Mating Tab Width | Glow Wire Compliant | Length - Tab | Features | Length | Width | Length - Overall | Tab Thickness | Width - Tab | Radiation Hardening | REACH SVHC | RoHS Status | Lead Free |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() 0190160085 Molex | 2736 |
| Datasheet | 3 Weeks | - | - | - | Free Hanging (In-Line) | - | - | Brass | - | - | Bulk | - | Krimptite | - | Active | 1 (Unlimited) | Crimp | - | - | - | - | - | Female | - | - | - | - | Electro-Tin | 12-14 AWG | - | - | - | - | - | - | - | - | Non-Insulated | Standard | - | - | - | - | 0.310 7.87mm | - | - | - | 0.660 16.76mm | 0.032 0.81mm | 0.250 6.35mm | - | - | ROHS3 Compliant | - | ||
![]() 0197114203 Molex | In Stock | - | Datasheet | - | - | - | - | Through Hole, Right Angle | - | - | Brass | - | - | Reel | - | 19711 | yes | Obsolete | 1 (Unlimited) | Solder | EAR99 | - | - | - | - | Male | 8536.90.40.00 | - | - | - | Tin-Lead | - | - | - | - | - | - | TAB TERMINAL | - | - | Non-Insulated | Angled - 90° | - | - | - | - | - | - | - | - | - | 0.032 0.81mm | 0.250 6.35mm | - | - | ROHS3 Compliant | - | ||
![]() 0357111100 Molex | In Stock | - | Datasheet | - | - | - | Free Hanging | Free Hanging (In-Line) | - | - | Brass | - | - | Reel | - | 35711 | - | Active | 1 (Unlimited) | Crimp | - | - | - | - | - | Female | - | Straight | - | - | - | 20-22 AWG | - | 22 AWG | 20 AWG | 20 AWG | - | - | - | 0.059 ~ 0.079 (1.50mm ~ 2.00mm) | Non-Insulated | Standard | - | - | - | - | 0.248 6.30mm | - | 15.3924mm | - | 0.606 15.40mm | 0.032 0.81mm | 0.110 2.79mm | No | - | ROHS3 Compliant | - | ||
![]() 0357181510 Molex | In Stock | - | Datasheet | - | - | Tin | - | Free Hanging (In-Line) | Brass | - | Brass | - | 250V | Reel | - | 35718 | - | Obsolete | 1 (Unlimited) | Crimp | - | - | 105°C | -40°C | - | Female | - | Straight | - | - | Tin | 10-14 AWG | Compliant | 10 AWG | 14 AWG | - | - | - | Low Halogen | 0.173 ~ 0.209 (4.39mm ~ 5.31mm) | Non-Insulated | Standard | - | - | - | Non-compliant | 0.252 6.40mm | - | - | - | 0.772 19.61mm | 0.020 0.51mm | 0.187 4.75mm | - | No SVHC | ROHS3 Compliant | - | ||
![]() 0190130032 Molex | 46 |
| Datasheet | 5 Weeks | - | - | - | Free Hanging (In-Line) | - | - | Brass | - | - | Tape & Reel (TR) | - | InsulKrimp | yes | Active | 1 (Unlimited) | Crimp | EAR99 | - | - | - | Blue | Female and Male | 8536.90.40.00 | - | - | - | Tin | 14-16 AWG | - | - | - | - | - | PUSH-ON TERMINAL | - | 0.259 (6.58mm) | Fully Insulated | Stacked | - | - | - | - | 0.310 7.87mm | - | - | - | 0.940 23.88mm | 0.032 0.81mm | 0.250 6.35mm | - | - | ROHS3 Compliant | - | ||
![]() 0357254110 Molex | In Stock | - | Datasheet | - | - | - | Free Hanging | Free Hanging (In-Line) | - | - | Brass | - | - | Reel | - | 35725 | yes | Last Time Buy | 1 (Unlimited) | Crimp | EAR99 | - | - | - | - | Female | 8536.90.40.00 | - | - | - | Tin | 18-20 AWG | - | 20 AWG | 18 AWG | - | - | TAB TERMINAL | - | - | Non-Insulated | Standard | - | - | - | - | 0.307 7.80mm | - | 19.6088mm | - | 0.772 19.61mm | 0.032 0.81mm | 0.250 6.35mm | No | - | ROHS3 Compliant | - | ||
![]() 0190050005 Molex | 6010 |
| Datasheet | 4 Weeks | - | - | - | Free Hanging (In-Line) | - | - | Brass | - | - | Bulk | - | InsulKrimp | - | Active | 1 (Unlimited) | Crimp | - | - | - | - | Blue | Female | - | - | - | - | Tin | 14-16 AWG | - | - | - | - | - | - | - | 0.165 (4.19mm) | Fully Insulated | Standard | - | - | - | - | - | - | - | - | 0.890 22.61mm | 0.032 0.81mm | 0.250 6.35mm | - | - | ROHS3 Compliant | - | ||
![]() 0190030050 Molex | 29015 |
| Datasheet | 9 Weeks | - | - | - | Free Hanging (In-Line) | - | - | Brass | - | - | Bulk | - | InsulKrimp | - | Active | 1 (Unlimited) | Crimp | - | - | - | - | Blue | Female | - | - | - | - | Tin | 14-16 AWG | - | - | - | - | - | - | - | 0.160 (4.06mm) | Fully Insulated | Standard | - | - | - | - | - | - | - | - | 0.780 19.81mm | 0.020 0.51mm | 0.187 4.75mm | - | - | ROHS3 Compliant | - | ||
Tiny WHSL | 17 |
| Datasheet | 3 Weeks | - | - | - | Free Hanging (In-Line) | - | - | Copper, ETP | - | - | Bulk | 2000 | Scotchlok™ | - | Active | 1 (Unlimited) | Crimp | - | - | - | - | Blue | Male | - | - | - | - | Tin | 14-16 AWG | - | - | - | - | - | - | - | 0.145 (3.68mm) | Fully Insulated | Standard | - | - | - | - | - | Butted Seam | - | - | 0.870 22.10mm | 0.020 0.51mm | 0.187 4.75mm | - | - | RoHS Compliant | - | ||
Tiny WHSL | In Stock | - | - | 3 Weeks | - | - | Free Hanging | Free Hanging (In-Line) | - | 357.884408g | - | - | - | Bulk | - | Scotchlok™ | - | Active | 1 (Unlimited) | Crimp | - | - | - | - | Yellow | Female | - | - | - | - | - | 20-26 AWG | - | 26 AWG | 20 AWG | - | - | - | - | 0.093 (2.36mm) | Non-Mating End Insulated | Standard | - | - | - | - | - | - | 16.002mm | - | 0.630 16.00mm | 0.032 0.81mm | 0.110 2.79mm | - | - | RoHS Compliant | - | ||
![]() 31103 Littelfuse Inc. | In Stock | - | - | 15 Weeks | - | - | - | - | - | - | - | - | - | - | - | - | - | Active | 1 (Unlimited) | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Non-RoHS Compliant | - | ||
![]() DNF14-250FIMB-L Panduit Corp | In Stock | - | - | - | - | - | Free Hanging | Free Hanging (In-Line) | - | 68.038855g | Brass | Nylon | - | Bulk | 2001 | Pan-Term® | - | Obsolete | Not Applicable | Crimp | - | INTERCONNECTION DEVICE | - | - | Blue | Male | - | - | - | unknown | Nickel | 14-16 AWG | - | 16 AWG | 14 AWG | - | - | - | - | 0.160 (4.06mm) | Fully Insulated | Standard | - | - | - | - | - | Serrated Termination | 23.114mm | 11.4mm | 0.910 23.11mm | 0.032 0.81mm | 0.250 6.35mm | - | - | Non-RoHS Compliant | - | ||
![]() P1015-14 Littelfuse Inc. | 46 |
| Datasheet | 9 Weeks | - | - | - | Free Hanging (In-Line) | - | - | - | - | - | Bulk | - | - | - | Active | - | Crimp | - | - | - | - | - | Female | - | - | - | - | - | 18-22 AWG | - | - | - | - | - | - | - | - | Non-Mating End Insulated | Standard | - | - | - | - | - | - | - | - | - | - | 0.250 6.35mm | - | - | - | - | ||
![]() FLVZDF1.25-250A-TOR(S)(LF) JST Sales America Inc. | In Stock | - | Datasheet | 16 Weeks | - | - | - | Free Hanging (In-Line) | - | - | - | - | - | Bulk | - | - | - | Active | - | Crimp | - | - | - | - | Red | Female | - | - | - | - | - | 16-22 AWG | - | - | - | - | - | - | - | 0.142 (3.61mm) | Fully Insulated | Standard | - | - | - | - | 0.307 7.80mm | - | - | - | 0.886 22.50mm | 0.031 0.79mm | 0.250 6.35mm | - | - | RoHS Compliant | Lead Free | ||
![]() S531-34 Harwin Inc. | In Stock | - | Datasheet | - | - | - | - | Through Hole, Right Angle | - | - | Brass | - | - | Bulk | - | - | yes | Obsolete | 1 (Unlimited) | Solder | EAR99 | - | - | - | - | Male | 8536.90.40.00 | - | - | unknown | Tin-Lead | - | - | - | - | - | - | TAB TERMINAL | - | - | Non-Insulated | Angled - 90° | - | - | - | - | - | - | - | - | - | 0.031 0.79mm | 0.250 6.35mm | - | - | ROHS3 Compliant | - | ||
![]() 1544615-1 TE Connectivity | In Stock | - | - | - | ACTIVE (Last Updated: 3 days ago) | Tin | Free Hanging | - | - | - | - | - | - | Tape & Reel (TR) | - | - | - | - | - | Crimp | - | - | 185°C | -40°C | - | Female | - | - | 7.5mm | - | - | - | Compliant | 22 AWG | 19 AWG | - | No | - | - | 1.78 mm | Non-Insulated | - | Tin | - | 6.35mm | - | 8.3058mm | - | 21.4122mm | - | - | 812.8μm | 6.35mm | No | - | RoHS Compliant | Lead Free | ||
![]() DNF18250FIBX-C Panduit Corp | In Stock | - | Datasheet | - | - | - | Free Hanging | Free Hanging (In-Line) | - | - | Brass | Nylon | - | Bulk | 2009 | Disco™ | - | Obsolete | Not Applicable | Crimp | EAR99 | - | - | - | Red | Female | 8536.90.40.00 | - | - | unknown | Tin | 18-22 AWG | - | 22 AWG | 18 AWG | - | - | WIRE TERMINAL | - | 0.210 (5.33mm) | Fully Insulated | Standard | - | 1 mm2 | - | - | - | Serrated Termination | 23.622mm | 8.89mm | 0.930 23.62mm | 0.032 0.81mm | 0.250 6.35mm | - | - | Non-RoHS Compliant | - | ||
![]() DV18-205B-M Panduit Corp | In Stock | - | - | - | - | - | Free Hanging | Free Hanging (In-Line) | - | - | Brass | Vinyl | - | Bulk | 2003 | Pan-Term® | - | Obsolete | Not Applicable | Crimp | EAR99 | - | - | - | Red | Female | 8536.90.40.00 | - | - | unknown | Tin | 18-22 AWG | - | 22 AWG | 18 AWG | - | - | PUSH-ON TERMINAL | - | 0.150 (3.81mm) | Non-Mating End Insulated | Standard | - | - | - | - | - | Butted Seam | 18.8976mm | 6.35mm | 0.744 18.90mm | 0.032 0.81mm | 0.187 4.75mm 0.205 5.21mm | - | - | Non-RoHS Compliant | - | ||
![]() DNF18-250FIM-C Panduit Corp | In Stock | - | - | - | - | - | Free Hanging | Free Hanging (In-Line) | - | 122.46994g | Brass | Nylon | - | Bulk | 2001 | Pan-Term® | - | Obsolete | Not Applicable | Crimp | - | INTERCONNECTION DEVICE | - | - | Red | Male | - | Straight | - | compliant | Nickel | 18-22 AWG | - | 22 AWG | 18 AWG | - | - | - | - | 0.133 (3.38mm) | Fully Insulated | Standard | - | - | - | - | - | Serrated Termination | 22.86mm | 10.7mm | 0.900 22.86mm | 0.032 0.81mm | 0.250 6.35mm | - | - | Non-RoHS Compliant | - | ||
![]() DNFR18-250B-C Panduit Corp | In Stock | - | - | - | - | - | Free Hanging | Free Hanging (In-Line), Right Angle | - | 158.757329g | Brass | Nylon | - | Bulk | 2001 | Pan-Term® | - | Obsolete | Not Applicable | Crimp | EAR99 | - | - | - | Red | Female | 8536.90.40.00 | - | - | compliant | Tin | 18-22 AWG | - | 22 AWG | 18 AWG | - | - | PUSH-ON TERMINAL | - | 0.130 (3.30mm) | Fully Insulated | Angled - 90°, Flag | - | 1 mm2 | - | - | - | - | 32.004mm | 9.14mm | - | 0.032 0.81mm | 0.250 6.35mm | - | - | Non-RoHS Compliant | - |