Product | Inventory | Pricing(USD) | Quantity | Datasheet | RoHS | Body material | AC contacts rating @R | Body dimensions | Certificates | Colour | Colour1 | Connections | Contact current max. | Contacts configuration | Contacts electrical parameters | Contacts electrical parameters1 | DC contacts rating @R | Force | Gross weight | Kind of actuator | Line | Manufacturer series | Mechanical durability | Mounting holes pitch | Number of key entry slots | Number of mounting holes | Related items | Related items1 | Safety outputs | Safety outputs1 | Safety switches features | Safety switches features1 | Supply voltage1 | Switched voltage | Switched voltage1 | Switches features | Trade name | Type of safety switch | Type of sensor | Operating temperature | Supply voltage | Output configuration | Electrical connection | IP rating |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() XCSB502 TELEMECANIQUE SENSORS | 2354 |
| - | metal | - | - | RoHS compliant | red | - | - | - | NC + NO x2 | 250V DC / 0.27A | 250V AC / 3A | - | - | 522.2g | - | - | XCSB | 1000000 cycles | - | 2 | - | XCSZ25 | XCSZ05 | - | - | manual-reset | without LED | - | - | - | slow action contacts | PREVENTA | key operated | - | -25...70°C | - | - | M20 | IP67 | ||
![]() XCSD3919G13 TELEMECANIQUE SENSORS | 2829 |
| - | metal | 1.5A / 240V AC | 34x65x34mm | RoHS compliant | - | - | PG13,5 | 1.5A | - | - | - | 0.1A / 250V DC | - | 249.1g | lever R 33mm, metallic roller 19mm | - | - | - | 20...22mm | - | 2 | - | - | - | - | - | - | - | max. 250V AC | max. 250V DC | snap action contacts | PREVENTA | - | limit switch | -25...70°C | - | NC x2 + NO | - | IP68 | ||
![]() XCSM3710L2 TELEMECANIQUE SENSORS | 2734 |
| - | metal | 1.5A / 240V AC | 50x30x16mm | RoHS compliant | - | - | lead 2m | 1.5A | - | - | - | 0.1A / 250V DC | - | 280g | pin plunger Ø7mm | - | - | - | 20mm | - | 2 | - | - | - | - | - | - | - | max. 250V AC | max. 250V DC | slow action contacts | PREVENTA | - | limit switch | -25...70°C | - | NC x2 + NO | - | IP68 | ||
![]() XY2CJR19 TELEMECANIQUE SENSORS | 2320 |
| - | metal | - | - | RoHS compliant | grey | red | - | - | NC x2 + NO | 240V AC / 3A | 250V DC / 0.27A | - | - | 792g | with reset | 30m - single side mounting switch | XY2CJ | - | - | - | - | - | - | - | - | - | - | - | - | - | - | PREVENTA | singlesided rope switch | - | -25...70°C | - | - | PG13,5 | IP67 | ||
![]() XY2CJR15H29 TELEMECANIQUE SENSORS | 2502 |
| - | metal | - | - | RoHS compliant | grey | red | - | - | NC + NO | 240V AC / 3A | 250V DC / 0.27A | - | - | 814g | with reset | 30m - single side mounting switch | XY2CJ | - | - | - | - | - | - | - | - | - | - | - | - | - | - | PREVENTA | singlesided rope switch | - | -25...70°C | - | - | M20 | IP67 | ||
![]() XY2CE1A270H7 TELEMECANIQUE SENSORS | 2625 |
| - | metal | - | - | RoHS compliant | grey | red | - | - | NC x2 | 240V AC / 3A | 250V DC / 0.27A | - | - | 1500g | with reset | 70m - one side mounted switch | XY2CE | - | - | - | - | - | - | - | - | - | - | - | - | - | - | PREVENTA | singlesided rope switch | - | -25...70°C | - | - | 1/2NPT | IP67 | ||
![]() XCSM4115L1 TELEMECANIQUE SENSORS | 55 |
| - | metal | 1.5A / 240V AC | 50x30x16mm | RoHS compliant | - | - | lead 1m | 1.5A | - | - | - | 0.1A / 250V DC | - | 228g | lever R 30,4mm, plastic roller Ø16mm | - | - | - | 20mm | - | 2 | - | - | - | - | - | - | - | max. 250V AC | max. 250V DC | snap action contacts | PREVENTA | - | limit switch | -25...70°C | - | NC x2 + NO x2 | - | IP68 | ||
![]() XCSE5312 TELEMECANIQUE SENSORS | 910 |
| - | metal | - | - | RoHS compliant | red | - | - | - | NC + NO | 240V AC / 1.5A | 250V DC / 0.27A | - | 2kN | 1305.4g | - | - | XCSE | - | - | 4 | - | XCSZ01 | XCSZ05 | NC x1 | NO x2 | no key | power to release | 24V DC | - | - | - | PREVENTA | bolting | - | -25...40°C | 24V AC | - | M20 x2 | IP67 | ||
![]() XCSLF2727313 TELEMECANIQUE SENSORS | 2251 |
| - | metal | - | - | RoHS compliant | red | - | - | - | NC x2 | 240V AC / 0.75A | 250V DC / 100mA | - | 3kN | 1270g | - | - | XCSLF | - | - | 2 | - | XCSZ01 | XCSZ05 | NC x2 | - | no key | power to release | 24V DC | - | - | - | PREVENTA | bolting | - | -25...60°C | 24V AC | - | 1/2NPT x3 | IP66 | ||
![]() XCSC703 TELEMECANIQUE SENSORS | 2463 |
| - | metal | - | - | RoHS compliant | red | - | - | - | NC x2 + NO | 250V DC / 0.27A | 250V AC / 3A | - | - | 502g | - | - | XCSC | 1000000 cycles | - | 2 | - | XCSZ25 | XCSZ05 | - | - | manual-reset | without LED | - | - | - | slow action contacts | PREVENTA | key operated | - | -25...70°C | - | - | 1/2NPT | IP67 | ||
![]() XCSD3718P20 TELEMECANIQUE SENSORS | 18 |
| - | metal | 1.5A / 240V AC | 34x65x34mm | RoHS compliant | - | - | M20 | 1.5A | - | - | - | 0.1A / 250V DC | - | 244g | lever R 33mm, plastic roller Ø19mm | - | - | - | 20...22mm | - | 2 | - | - | - | - | - | - | - | max. 250V AC | max. 250V DC | slow action contacts | PREVENTA | - | limit switch | -25...70°C | - | NC x2 + NO | - | IP68 | ||
![]() XCSLF2727312 TELEMECANIQUE SENSORS | 2622 |
| - | metal | - | - | RoHS compliant | red | - | - | - | NC x2 | 240V AC / 0.75A | 250V DC / 100mA | - | 3kN | 1289.3g | - | - | XCSLF | - | - | 2 | - | XCSZ01 | XCSZ05 | NC x2 | - | no key | power to release | 24V DC | - | - | - | PREVENTA | bolting | - | -25...60°C | 24V AC | - | M20 x3 | IP66 | ||
![]() XCSC502 TELEMECANIQUE SENSORS | 2659 |
| - | metal | - | - | RoHS compliant | red | - | - | - | NC + NO x2 | 250V DC / 0.27A | 250V AC / 3A | - | - | 541.05g | - | - | XCSC | 1000000 cycles | - | 2 | - | XCSZ25 | XCSZ05 | - | - | manual-reset | without LED | - | - | - | slow action contacts | PREVENTA | key operated | - | -25...70°C | - | - | M20 | IP67 | ||
![]() XCSD3718G13 TELEMECANIQUE SENSORS | 2540 |
| - | metal | 1.5A / 240V AC | 34x65x34mm | RoHS compliant | - | - | PG13,5 | 1.5A | - | - | - | 0.1A / 250V DC | - | 264g | lever R 33mm, plastic roller Ø19mm | - | - | - | 20...22mm | - | 2 | - | - | - | - | - | - | - | max. 250V AC | max. 250V DC | slow action contacts | PREVENTA | - | limit switch | -25...70°C | - | NC x2 + NO | - | IP68 | ||
![]() XCSE5311 TELEMECANIQUE SENSORS | 993 |
| - | metal | - | - | RoHS compliant | red | - | - | - | NC + NO | 240V AC / 1.5A | 250V DC / 0.27A | - | 2kN | 1316.2g | - | - | XCSE | - | - | 4 | - | XCSZ01 | XCSZ05 | NC x1 | NO x2 | no key | power to release | 24V DC | - | - | - | PREVENTA | bolting | - | -25...40°C | 24V AC | - | PG13,5 x2 | IP67 | ||
![]() XCSLE2727313 TELEMECANIQUE SENSORS | 2382 |
| - | plastic | - | - | RoHS compliant | red | - | - | - | NC x2 | 240V AC / 0.75A | 250V DC / 100mA | - | 1400N | 628g | - | - | XCSLE | 1000000 cycles | - | 2 | - | XCSZ01 | XCSZ05 | NC x2 | - | no key | power to release | 24V DC | - | - | - | PREVENTA | bolting | - | -25...60°C | 24V AC | - | 1/2NPT x3 | IP66 | ||
![]() XCSC501 TELEMECANIQUE SENSORS | 2914 |
| - | metal | - | - | RoHS compliant | red | - | - | - | NC + NO x2 | 250V DC / 0.27A | 250V AC / 3A | - | - | 543g | - | - | XCSC | 1000000 cycles | - | 2 | - | XCSZ25 | XCSZ05 | - | - | manual-reset | without LED | - | - | - | slow action contacts | PREVENTA | key operated | - | -25...70°C | - | - | PG13,5 | IP67 | ||
![]() XCSC702 TELEMECANIQUE SENSORS | 2195 |
| - | metal | - | - | RoHS compliant | red | - | - | - | NC x2 + NO | 250V DC / 0.27A | 250V AC / 3A | - | - | 541.42g | - | - | XCSC | 1000000 cycles | - | 2 | - | XCSZ25 | XCSZ05 | - | - | manual-reset | without LED | - | - | - | slow action contacts | PREVENTA | key operated | - | -25...70°C | - | - | M20 | IP67 | ||
![]() XCSD3702G13 TELEMECANIQUE SENSORS | 2979 |
| - | metal | 1.5A / 240V AC | 34x65x34mm | RoHS compliant | - | - | PG13,5 | 1.5A | - | - | - | 0.1A / 250V DC | - | 224g | metal roller Ø11,6mm | - | - | - | 20...22mm | - | 2 | - | - | - | - | - | - | - | max. 250V AC | max. 250V DC | slow action contacts | PREVENTA | - | limit switch | -25...70°C | - | NC x2 + NO | - | IP68 | ||
![]() XCSD3918G13 TELEMECANIQUE SENSORS | 2135 |
| - | metal | 1.5A / 240V AC | 34x65x34mm | RoHS compliant | - | - | PG13,5 | 1.5A | - | - | - | 0.1A / 250V DC | - | 240g | lever R 33mm, plastic roller Ø19mm | - | - | - | 20...22mm | - | 2 | - | - | - | - | - | - | - | max. 250V AC | max. 250V DC | snap action contacts | PREVENTA | - | limit switch | -25...70°C | - | NC x2 + NO | - | IP68 |