- Actuator Type
- Number of Poles
- Series
- Voltage Rating DC
- Approval Agency
- Breaker Type
- Current Rating (Amps)
- Illumination
- Illumination Voltage (Nominal)
- Mfr
- Mounting Type
- Product Status
Attribute column
Manufacturer
Carling Technologies Circuit Breakers
Product | Inventory | Pricing(USD) | Quantity | Datasheet | RoHS | Factory Lead Time | Mounting Type | Surface Mount | Terminal Shape | Mounting Feature | Mounting Hole Diameter | Brand | Factory Pack QuantityFactory Pack Quantity | Ihs Manufacturer | Illuminated | Manufacturer | Manufacturer Part Number | Maximum Operating Temperature | Mfr | Minimum Operating Temperature | Mounting Hole Size | Mounting Styles | Operating Temp Range | Operating Temperature-Max | Operating Temperature-Min | Package | Part Life Cycle Code | Product Status | Risk Rank | RoHS | Rohs Code | Unit Weight | Usage Level | Voltage Rating DC | Voltage, Rating | Series | Type | Applications | Subcategory | Current Rating (Amps) | Reach Compliance Code | Current Rating | Reference Standard | Termination Style | Approval Agency | Body Length or Diameter | Body Breadth | Physical Dimension | Actuator Type | Illumination Voltage (Nominal) | Environmental Characteristics | Number of Poles | Illumination | Breaker Type | Product Type | Rated Current | Circuit Protection Type | Screening Level | Blow Characteristic | Rated Voltage(DC) | Overall Length | Rated Breaking Capacity | Rated Voltage(AC) | Circuit Function | Product | Compliance | Overall Depth | Product Category | Height | Length | Width | Body Height |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() ME1-B-94-440-2-A22-A-C Carling Technologies | In Stock | - | - | - | Panel Mount | - | - | - | - | Carling Technologies | 1 | - | Non-Illuminated | Carling Technologies | - | + 85 C | Carling Technologies | - 40 C | - | Snap-In | -40C to 85C | - | - | Bulk | - | Active | - | - | - | 1.058219 oz | Industrial grade | 80 V | 125VAC/32VDC | M | Magnetic | - | Circuit Breakers | 4A | - | 4(A) | - | Screw | CSA, UL1077 | - | - | - | Rocker | - | - | 1 | None | Magnetic (Hydraulic Delay) | - | - | - | Industrial | - | - | - | - | - | - | Circuit Breakers | - | - | Circuit Breakers | - | - | - | - | ||
![]() CA1-B0-22-625-121-C Carling Technologies | In Stock | - | - | 4 Weeks | Panel Mount | - | - | - | - | Carling Technologies | 1 | CARLING TECHNOLOGIES INC | Not Illuminated | Carling Technologies | CA1-B0-22-625-121-C | + 85 C | Carling Technologies | - 40 C | - | Panel | - | - | - | Bulk | Active | Active | 5.57 | - | - | 4 oz | - | 125 VDC | 277VAC/480VAC | C | HYDRAULIC MAGNETIC | - | Circuit Breakers | 25A | compliant | 25(A) | - | Stud | CSA, UL | - | - | - | Handle | - | - | 1 | None | Magnetic (Hydraulic Delay) | - | - | MAGNETIC CIRCUIT BREAKER | - | - | - | - | - | - | - | Circuit Breakers | - | - | Circuit Breakers | 63.5 mm | 47 mm | 19.18 mm | - | ||
![]() CA1-B2-46-615-121-KG Carling Technologies | 15 |
| - | 4 Weeks | Panel Mount | - | - | - | - | Carling Technologies | 1 | CARLING TECHNOLOGIES INC | Not Illuminated | Carling Technologies | CA1-B2-46-615-121-KG | + 85 C | Carling Technologies | - 40 C | - | Panel | - | - | - | Bulk | Active | Active | 1.94 | - | - | 4 oz | - | 125 VDC | 277VAC/480VAC | C | HYDRAULIC MAGNETIC | - | Circuit Breakers | 15A | compliant | 15(A) | - | Stud | CSA, UL489 | - | - | - | Handle | - | - | 1 | None | Magnetic (Hydraulic Delay) | - | - | MAGNETIC CIRCUIT BREAKER | - | - | - | - | - | - | - | Circuit Breakers | - | - | Circuit Breakers | 63.5 mm | 47 mm | 19.18 mm | - | ||
![]() CA1-B2-16-810-A21-MG Carling Technologies | In Stock | - | - | 4 Weeks | Panel Mount | - | - | - | - | Carling Technologies | 1 | CARLING TECHNOLOGIES INC | Not Illuminated | Carling Technologies | CA1-B2-16-810-A21-MG | + 85 C | Carling Technologies | - 40 C | - | Panel | - | - | - | Bulk | Active | Active | 1.93 | - | - | 4 oz | - | 80 VDC | 277VAC/480VAC | C | HYDRAULIC MAGNETIC | - | Circuit Breakers | 100A | compliant | 100(A) | - | Stud | CSA, UL489 | - | - | - | Handle | - | - | 1 | None | Magnetic (Hydraulic Delay) | - | - | MAGNETIC CIRCUIT BREAKER | - | - | - | - | - | - | - | Circuit Breakers | - | - | Circuit Breakers | 63.5 mm | 47 mm | 19.18 mm | - | ||
![]() MS1-B-14-630-3-1CB-A-C Carling Technologies | 2819 |
| - | 4 Weeks | Panel Mount | - | - | - | - | - | - | CARLING TECHNOLOGIES INC | Not Illuminated | Carling Technologies | MS1-B-14-630-3-1CB-A-C | + 85 C | Carling Technologies | - 40 C | - | - | - | - | - | Bulk | Active | Active | 1.93 | - | - | - | - | 65 V | - | MS | Hydraulic-Magnetic | - | - | 30A | compliant | 30 A | - | - | cURus, UL | - | - | - | Toggle | - | - | 1 | None | Magnetic (Hydraulic Delay) | - | - | THERMAL MAGNETIC | - | - | - | - | - | - | - | Circuit Breakers | - | - | - | - | - | - | - | ||
![]() EA3-B0-24-450-12A-GB Carling Technologies | 2214 |
| - | 4 Weeks | Panel Mount | - | - | - | - | Carling Technologies | 1 | CARLING TECHNOLOGIES INC | Not Illuminated | Carling Technologies | EA3-B0-24-450-12A-GB | + 85 C | Carling Technologies | - 40 C | - | Panel | -40C to 85C | - | - | Bulk | Active | Active | 1.94 | - | - | 1.667 lbs | Industrial grade | 125 VDC | 600VAC | E | HYDRAULIC MAGNETIC | - | Circuit Breakers | 5A | compliant | 5(A) | - | Stud | CSA, UL508, UL1077 | - | - | - | Handle | - | - | 3 | None | Magnetic (Hydraulic Delay) | Branch Circuit Protection | - | MAGNETIC CIRCUIT BREAKER | Industrial | - | - | - | - | - | - | Circuit Breakers | - | - | Circuit Breakers | - | - | - | - | ||
![]() AA1-B0-42-618-2D1-C Carling Technologies | 27 |
| - | 4 Weeks | Panel Mount | - | - | - | - | Carling Technologies | 1 | CARLING TECHNOLOGIES INC | Not Illuminated | Carling Technologies | AA1-B0-42-618-2D1-C | + 85 C | Carling Technologies | - 40 C | - | Panel | -40C to 85C | - | - | Bulk | Active | Active | 5.5 | Details | Yes | 2.292808 oz | Industrial grade | 80 VDC | 277VAC/80VDC | A | Hydraulic-Magnetic | - | Circuit Breakers | 18A | compliant | 18(A) | - | Screw | CSA, UL | - | - | - | Handle | - | - | 1 | None | Magnetic (Hydraulic Delay) | - | - | MAGNETIC CIRCUIT BREAKER | Industrial | - | - | - | - | - | - | Circuit Breakers | - | - | Circuit Breakers | 50.8 mm | 41.66 mm | 19.18 mm | - | ||
![]() DA1-B0-14-610-111-C Carling Technologies | 15 |
| - | 4 Weeks | DIN Rail | - | - | - | - | - | - | CARLING TECHNOLOGIES INC | Not Illuminated | Carling Technologies | DA1-B0-14-610-111-C | + 85 C | Carling Technologies | - 40 C | - | Din-Rail | -40C to 85C | - | - | Bulk | Active | Active | 2.07 | - | Yes | - | Industrial grade | 80 V | 277VAC/480VAC | D | - | - | - | 10A | compliant | 10(A) | - | Screw | CSA, UL | - | - | - | Lever | - | - | 1 | None | Magnetic (Hydraulic Delay) | - | - | MAGNETIC CIRCUIT BREAKER | Industrial | - | - | - | - | - | - | Circuit Breakers | - | - | - | - | - | - | - | ||
![]() AC2-B0-24-425-431-D Carling Technologies | 2660 |
| - | - | Panel Mount | - | - | - | - | Carling Technologies | 1 | - | Not Illuminated | Carling Technologies | - | + 85 C | Carling Technologies | - 40 C | - | Panel | -40C to 85C | - | - | Bulk | - | Active | - | - | - | 4.585615 oz | Industrial grade | 80 VDC | 277VAC/80VDC | A | Hydraulic-Magnetic | - | Circuit Breakers | 2.5A | - | 2.5(A) | - | Quick Connect | CSA, VDE, UL | - | - | - | Rocker | - | - | 2 | None | Magnetic (Hydraulic Delay) | - | - | - | Industrial | - | - | - | - | - | - | Circuit Breakers | - | - | Circuit Breakers | 50.8 mm | 41.66 mm | 38.48 mm | - | ||
![]() MS1-B-14-610-3-1CB-A-C Carling Technologies | 2347 |
| - | - | Panel Mount | - | - | - | 9.9mm | Carling Technologies | 1 | - | Not Illuminated | Carling Technologies | - | + 85 C | Carling Technologies | - 40 C | 9.93 (Dia.)mm | Panel Mount | - | - | - | Bulk | - | Active | - | - | - | 1.763698 oz | - | 65 VDC | 50V dc | MS | Supplementary Protector | Automotive, Communication Equipment, COTS Military Application, Generators, Power Supplies | Circuit Breakers | 10A | - | 10A | - | Screw | cURus, UL | - | - | - | Toggle | - | - | 1 | None | Magnetic (Hydraulic Delay) | - | - | - | - | - | - | 16.7mm | - | - | - | Circuit Breakers | - | 66.9mm | Circuit Breakers | - | - | - | - | ||
![]() BA3-B0-46-620-311-D Carling Technologies | In Stock | - | - | - | Panel Mount | - | - | - | - | Carling Technologies | 1 | - | - | Carling Technologies | - | - | Carling Technologies | - | - | Panel | - | - | - | Bulk | - | Active | - | Details | - | 6.878423 oz | - | 80 VDC | - | B | Supplementary Protector | - | Circuit Breakers | 20A | - | 20(A) | - | Screw | CSA, VDE, UL | - | - | - | Lever | - | - | 3 | None | Magnetic (Hydraulic Delay) | - | - | - | - | - | - | - | - | - | - | Circuit Breakers | - | - | Circuit Breakers | - | - | - | - | ||
![]() AB2-B0-26-450-2D1-C Carling Technologies | 2287 |
| - | 4 Weeks | Panel Mount | - | - | - | - | Carling Technologies | 1 | CARLING TECHNOLOGIES INC | Not Illuminated | Carling Technologies | AB2-B0-26-450-2D1-C | + 85 C | Carling Technologies | - 40 C | - | Panel | -40C to 85C | - | - | Bulk | Active | Active | 2.11 | Details | Yes | 4.585615 oz | Industrial grade | 80 VDC | 277VAC/80VDC | A | Hydraulic-Magnetic | - | Circuit Breakers | 5A | compliant | 5(A) | - | Screw | CSA, UL | - | - | - | Handle | - | - | 2 | None | Magnetic (Hydraulic Delay) | - | - | MAGNETIC CIRCUIT BREAKER | Industrial | - | - | - | - | - | - | Circuit Breakers | UL Recognized; CSA | - | Circuit Breakers | 50.8 mm | 41.66 mm | 38.48 mm | - | ||
![]() AF1-B0-44-610-531-D Carling Technologies | 19 |
| - | 4 Weeks | Panel Mount | - | - | - | - | Carling Technologies | 1 | CARLING TECHNOLOGIES INC | Not Illuminated | Carling Technologies | AF1-B0-44-610-531-D | + 85 C | Carling Technologies | - 40 C | - | Panel Mount | - | - | - | Bulk | Active | Active | 5.52 | Details | Yes | 2.292808 oz | - | 80 VDC | 277 VAC, 80 VDC | A | Hydraulic-Magnetic | - | Circuit Breakers | 10A | compliant | 10 A | - | Screw | CSA, VDE, UL | - | - | - | Rocker | - | - | 1 Pole | None | Magnetic (Hydraulic Delay) | - | - | MAGNETIC CIRCUIT BREAKER | - | - | - | - | - | - | - | Circuit Breakers | - | - | Circuit Breakers | 50.8 mm | 41.66 mm | 18.92 mm | - | ||
![]() MS1-B-14-450-3-1CB-A-C Carling Technologies | 2392 |
| - | 4 Weeks | Panel Mount | - | - | - | 9.9mm | Carling Technologies | 1 | CARLING TECHNOLOGIES INC | Not Illuminated | Carling Technologies | MS1-B-14-450-3-1CB-A-C | + 85 C | Carling Technologies | - 40 C | 9.93 (Dia.)mm | Panel Mount | - | - | - | Bulk | Active | Active | 5.47 | - | - | 1.763698 oz | - | 65 VDC | 50V dc | MS | Supplementary Protector | Automotive, Communication Equipment, COTS Military Application, Generators, Power Supplies | Circuit Breakers | 5A | compliant | 5A | - | Screw | cURus, UL | - | - | - | Toggle | - | - | 1 | None | Magnetic (Hydraulic Delay) | - | - | THERMAL MAGNETIC | - | - | - | 16.7mm | - | - | - | Circuit Breakers | - | 66.9mm | Circuit Breakers | - | - | - | - | ||
![]() AB3-F0-20-610-2D1-C Carling Technologies | 2421 |
| - | 4 Weeks | Panel Mount | - | - | - | - | Carling Technologies | 1 | CARLING TECHNOLOGIES INC | Not Illuminated | Carling Technologies | AB3-F0-20-610-2D1-C | + 85 C | Carling Technologies | - 40 C | - | Panel | -40C to 85C | - | - | Bulk | Active | Active | 2.11 | Details | Yes | - | Industrial grade | 80 V | 277VAC/80VDC | A | HYDRAULIC MAGNETIC | - | Circuit Breakers | 10A | compliant | 5(A) | - | Screw | CSA, UL | - | - | - | Lever | - | - | 3 | None | Magnetic (Hydraulic Delay) | - | - | MAGNETIC CIRCUIT BREAKER | Industrial | - | - | - | - | - | - | Circuit Breakers | - | - | Circuit Breakers | 50.8 mm | 41.66 mm | 38.48 mm | - | ||
![]() A21-B0-34-615-131-E Carling Technologies | 33 |
| - | 4 Weeks | Panel Mount | - | - | - | - | Carling Technologies | 1 | CARLING TECHNOLOGIES INC | Not Illuminated | Carling Technologies | A21-B0-34-615-131-E | + 85 C | Carling Technologies | - 40 C | - | Panel Mount | - | - | - | Bulk | Active | Active | 2.07 | Details | Yes | - | - | 80 V | 277 VAC, 80 VDC | A | Hydraulic-Magnetic | - | Circuit Breakers | 15A | compliant | - | - | - | CSA, TUV, UL | - | - | - | Rocker | - | - | 1 | None | Magnetic (Hydraulic Delay) | - | - | MAGNETIC CIRCUIT BREAKER | - | - | - | - | - | - | - | Circuit Breakers | UL Recognized; CSA; TUV | - | Circuit Breakers | - | - | - | - | ||
![]() A21-B2-34-615-131-E Carling Technologies | In Stock | - | - | 4 Weeks | Panel Mount | - | - | - | - | Carling Technologies | 1 | CARLING TECHNOLOGIES INC | Not Illuminated | Carling Technologies | A21-B2-34-615-131-E | + 85 C | Carling Technologies | - 40 C | - | Panel Mount | - | - | - | Bulk | Active | Active | 2.1 | Details | Yes | - | - | 80 V | 277 VAC, 80 VDC | A | Hydraulic-Magnetic | - | Circuit Breakers | 15A | compliant | - | - | - | CSA, TUV, UL | - | - | - | Rocker | - | - | 1 | None | Magnetic (Hydraulic Delay) | - | - | MAGNETIC CIRCUIT BREAKER | - | - | - | - | - | - | - | Circuit Breakers | UL Recognized; CSA; TUV | - | Circuit Breakers | - | - | - | - | ||
![]() AC1-B0-34-450-161-C Carling Technologies | In Stock | - | - | 4 Weeks | Panel Mount | - | - | - | - | Carling Technologies | 1 | CARLING TECHNOLOGIES INC | Not Illuminated | Carling Technologies | AC1-B0-34-450-161-C | + 85 C | Carling Technologies | - 40 C | - | Panel Mount | - | - | - | Bulk | Active | Active | 2.11 | Details | Yes | 2.292808 oz | - | 80 VDC | 277 VAC, 80 VDC | A | Hydraulic-Magnetic | - | Circuit Breakers | 5A | compliant | 5 A | - | Quick Connect | CSA, UL | - | - | - | Rocker | - | - | 1 Pole | None | Magnetic (Hydraulic Delay) | - | - | MAGNETIC CIRCUIT BREAKER | - | - | - | - | - | - | - | Circuit Breakers | - | - | Circuit Breakers | 50.8 mm | 41.66 mm | 18.92 mm | - | ||
![]() MM1-B-34-625-1-2AA-B-C Carling Technologies | In Stock | - | - | 4 Weeks | - | - | - | - | - | Carling Technologies | 1 | CARLING TECHNOLOGIES INC | Not Illuminated | Carling Technologies | MM1-B-34-625-1-2AA-B-C | + 85 C | - | - 40 C | - | Panel | -40C to 85C | - | - | - | Active | - | 5.52 | - | - | 1.058219 oz | Industrial grade | 80 VDC | 250VAC/65VDC | M | Magnetic | - | Circuit Breakers | - | compliant | 25(A) | - | Quick Connect | - | - | - | - | Paddle | - | - | 1 | - | - | - | - | MAGNETIC CIRCUIT BREAKER | Industrial | - | - | - | - | - | - | Circuit Breakers | - | - | Circuit Breakers | 34.93 mm | 35.43 mm | 17.27 mm | - | ||
![]() MD2-B-34-620-1-A36-B-C Carling Technologies | 25 |
| - | 4 Weeks | Panel Mount | NO | QUICK CONNECT | PANEL MOUNT | - | Carling Technologies | 10 | CARLING TECHNOLOGIES INC | Not Illuminated | Carling Technologies | MD2-B-34-620-1-A36-B-C | + 85 C | Carling Technologies | - 40 C | - | Snap-In | -40C to 85C | 85 °C | -40 °C | Bulk | Active | Active | 5.49 | Details | - | 2.116438 oz | Industrial grade | 80 VDC | 250VAC/65VDC | M | Magnetic | - | Circuit Breakers | 20A | compliant | 20(A) | CSA; UL | Quick Connect | CSA, UL1077 | 39.62 mm | 33.12 mm | 39.62mm x 33.12mm x 38.86mm | Rocker | - | CORROSSION RESISTANT | 2 | None | Magnetic (Hydraulic Delay) | - | 20 A | MAGNETIC CIRCUIT BREAKER | Industrial | MEDIUM | 80 V | - | 600 A | 250 V | SERIES TRIP | Circuit Breakers | UL Recognized; CSA | - | Circuit Breakers | - | - | - | 38.86 mm |