- Actuator Type
- Number of Poles
- Series
- Voltage Rating DC
- Approval Agency
- Breaker Type
- Current Rating (Amps)
- Illumination
- Illumination Voltage (Nominal)
- Mfr
- Mounting Type
- Product Status
Attribute column
Manufacturer
Carling Technologies Circuit Breakers
Product | Inventory | Pricing(USD) | Quantity | Datasheet | RoHS | Factory Lead Time | Mounting Type | Brand | Dielectric Strength | Factory Pack QuantityFactory Pack Quantity | Ihs Manufacturer | Illuminated | Manufacturer | Manufacturer Part Number | Maximum Operating Temperature | Mfr | Minimum Operating Temperature | Mounting Styles | Operating Temp Range | Package | Part Life Cycle Code | Product Status | Risk Rank | RoHS | Rohs Code | Terminal Design | Unit Weight | Usage Level | Voltage Rating DC | Voltage, Rating | Operating Temperature | Series | Type | Subcategory | Current Rating (Amps) | Reach Compliance Code | Current Rating | Termination Style | Approval Agency | Actuator Type | Illumination Voltage (Nominal) | Number of Poles | Illumination | Breaker Type | Product Type | Circuit Protection Type | Screening Level | Product | Compliance | Product Category | Height | Length | Width |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() CA2-B0-24-620-311-C Carling Technologies | 818 | - | - | 4 Weeks | Panel Mount | Carling Technologies | - | 1 | CARLING TECHNOLOGIES INC | Not Illuminated | Carling Technologies | CA2-B0-24-620-311-C | + 85 C | Carling Technologies | - 40 C | Panel | -40C to 85C | Bulk | Active | Active | 5.52 | - | - | - | 8 oz | Industrial grade | 125 VDC | 480VAC | - | C | HYDRAULIC MAGNETIC | Circuit Breakers | 20A | compliant | 20(A) | Stud | CSA, UL | Handle | - | 2 | None | Magnetic (Hydraulic Delay) | - | MAGNETIC CIRCUIT BREAKER | Industrial | Circuit Breakers | - | Circuit Breakers | 63.5 mm | 47 mm | 38.48 mm | ||
![]() BA2-B0-24-630-522-C Carling Technologies | 21 |
| - | 4 Weeks | Panel Mount | Carling Technologies | - | 1 | CARLING TECHNOLOGIES INC | Non-Illuminated | Carling Technologies | BA2-B0-24-630-522-C | - | Carling Technologies | - | - | - | Bulk | Active | Active | 1.94 | - | - | - | - | - | 80 V | - | - | B | - | Switches | 30A | compliant | - | - | CSA, UL | Lever | - | 2 | None | Magnetic (Hydraulic Delay) | Rocker Switches | MAGNETIC CIRCUIT BREAKER | - | - | - | Rocker Switches | - | - | - | ||
![]() CMBA-053-NNFNN-B-A/05 Carling Technologies | In Stock | - | - | - | Panel Mount | - | - | - | - | - | - | - | - | Carling Technologies | - | - | - | Bulk | - | Active | - | - | - | - | - | - | 32 V | - | - | CMBA | - | - | 5A | - | - | - | cUL,TUV, UL | Automatic Reset | - | 1 | None | Thermal | - | - | - | - | - | - | - | - | - | ||
![]() EA2-B0-24-810-22A-DB Carling Technologies | 2927 |
| - | 4 Weeks | Panel Mount | Carling Technologies | - | 1 | CARLING TECHNOLOGIES INC | Not Illuminated | Carling Technologies | EA2-B0-24-810-22A-DB | + 85 C | Carling Technologies | - 40 C | Panel | -40C to 85C | Bulk | Active | Active | 2.08 | Details | Yes | - | 1.111 lbs | Industrial grade | 125 VDC | 240VAC | - | E | HYDRAULIC MAGNETIC | Circuit Breakers | 100A | compliant | 100(A) | Stud | CSA, UL508, UL1077 | Handle | - | 2 | None | Magnetic (Hydraulic Delay) | Branch Circuit Protection | MAGNETIC CIRCUIT BREAKER | Industrial | Circuit Breakers | - | Circuit Breakers | 120.65 mm | 66.3 mm | 53.15 mm | ||
![]() MM1-B-32-250-2-3DB-B-C Carling Technologies | 32 |
| - | - | Panel Mount | Carling Technologies | - | 1 | - | Not Illuminated | Carling Technologies | - | + 85 C | Carling Technologies | - 40 C | Panel Mount | - | Bulk | - | Active | - | - | - | - | 1.058219 oz | - | 80 V | - | - | M | Hydraulic-Magnetic | Circuit Breakers | 500mA | - | 0.5 A | Screw | CSA, UL1077 | Lever | - | 1 | None | Magnetic (Hydraulic Delay) | - | - | - | Circuit Breakers | - | Circuit Breakers | 34.93 mm | 35.43 mm | 17.27 mm | ||
![]() MT1-B-14-630-1-A23-B-J Carling Technologies | 8 |
| - | - | Panel Mount | Carling Technologies | - | 1 | - | Not Illuminated | Carling Technologies | - | + 85 C | Carling Technologies | - 40 C | Panel Mount | - | Bulk | - | Active | - | Non-Compliant | - | - | 1.058219 oz | - | 80 V | - | - | M | Hydraulic-Magnetic | Circuit Breakers | 30A | - | 30 A | Quick Connect | TUV, UL489A | Push-Pull | - | 1 | None | Magnetic (Hydraulic Delay) | Circuit Breaker | - | - | Circuit Breakers | - | Circuit Breakers | 34.93 mm | 37.69 mm | 17.27 mm | ||
![]() AB2-B0-34-630-3B1-C Carling Technologies | 44 |
| - | - | Panel Mount | Carling Technologies | 1.5kV | 1 | - | Not Illuminated | Carling Technologies | - | + 85 C | Carling Technologies | - 40 C | Panel | -40C to 85C | Bulk | - | Active | - | Details | - | Screw | 4.585615 oz | Industrial grade | 80 VDC | 277, 80 Vac/Vdc | -40 to 85 °C | A | Hydraulic-Magnetic | Circuit Breakers | 30A | - | 30(A) | Screw | CSA, UL | Handle | - | 2 | None | Magnetic (Hydraulic Delay) | - | - | Industrial | Circuit Breakers | UL Recognized; CSA | Circuit Breakers | - | - | - | ||
![]() EA2-B0-26-650-12A-DC Carling Technologies | 2684 |
| - | 4 Weeks | Panel Mount | Carling Technologies | - | 1 | CARLING TECHNOLOGIES INC | Not Illuminated | Carling Technologies | EA2-B0-26-650-12A-DC | + 85 C | Carling Technologies | - 40 C | Panel Mount | - | Bulk | Active | Active | 5.5 | Details | Yes | - | 1.111 lbs | - | 125 VDC | 240VAC | - | E | HYDRAULIC MAGNETIC | Circuit Breakers | 50A | compliant | 50(A) | Stud | CSA, UL489 | Handle | - | 2 | None | Magnetic (Hydraulic Delay) | Branch Circuit Protection | MAGNETIC CIRCUIT BREAKER | - | Circuit Breakers | UL 489 Listed; CSA | Circuit Breakers | 120.65 mm | 66.3 mm | 53.15 mm | ||
![]() MU1-B-24-620-1-A21-B-C Carling Technologies | 15 |
| - | - | Panel Mount | Carling Technologies | - | 1 | - | Non-Illuminated | Carling Technologies | - | + 85 C | Carling Technologies | - 40 C | - | - | Bulk | - | Active | - | - | - | - | 1.058219 oz | - | 80 VDC | - | - | M | Hydraulic-Magnetic | Circuit Breakers | 20A | - | 20 A | - | CSA, UL1077 | Push to Reset | - | 1 | None | Magnetic (Hydraulic Delay) | - | - | - | Circuit Breakers | - | Circuit Breakers | - | - | - | ||
![]() GA3-B0-24-615-11-HC Carling Technologies | 2612 |
| - | 8 Weeks | DIN Rail | Carling Technologies | - | 1 | CARLING TECHNOLOGIES INC | Not Illuminated | Carling Technologies | GA3-B0-24-615-11-HC | + 85 C | Carling Technologies | - 40 C | Din-Rail | -40C to 85C | Bulk | Active | Active | 5.52 | - | - | - | - | Industrial grade | 125 V | 240VAC/125VDC | - | G | HYDRAULIC MAGNETIC | Circuit Breakers | 15A | compliant | 15(A) | Screw | UL | Lever | - | 3 | None | Magnetic (Hydraulic Delay) | Magnetic Circuit Breaker | MAGNETIC CIRCUIT BREAKER | Industrial | Circuit Breakers | UL Recognized | Circuit Breakers | 92.08 mm | 59.72 mm | 52.43 mm | ||
![]() EA3-B0-66-630-12A-GB Carling Technologies | In Stock | - | - | 4 Weeks | Panel Mount | Carling Technologies | - | 1 | CARLING TECHNOLOGIES INC | Not Illuminated | Carling Technologies | EA3-B0-66-630-12A-GB | + 85 C | Carling Technologies | - 40 C | Panel Mount | - | Bulk | Active | Active | 5.55 | Details | Yes | - | 1.667 lbs | - | 125 VDC | 600 VAC, 125 VDC | - | E | Hydraulic-Magnetic | Circuit Breakers | 30A | compliant | 30 A | Stud | CSA, UL508, UL1077 | Handle | - | 3 Pole | None | Magnetic (Hydraulic Delay) | Branch Circuit Protection | MAGNETIC CIRCUIT BREAKER | - | Circuit Breakers | - | Circuit Breakers | 120.65 mm | 66.3 mm | 79.7 mm | ||
![]() CA1-B0-22-640-121-C Carling Technologies | 25 |
| - | 4 Weeks | Panel Mount | - | - | - | CARLING TECHNOLOGIES INC | Non-Illuminated | Carling Technologies | CA1-B0-22-640-121-C | + 85 C | Carling Technologies | - 40 C | Panel | - | Bulk | Active | Active | 1.93 | - | - | - | - | - | 150 V | 277VAC/480VAC | - | C | HYDRAULIC MAGNETIC | - | 40A | compliant | 40(A) | Stud | CSA, UL | Lever | - | 1 | None | Magnetic (Hydraulic Delay) | - | MAGNETIC CIRCUIT BREAKER | - | Circuit Breakers | - | - | - | - | - | ||
![]() CA3-B0-34-650-331-C Carling Technologies | 2355 |
| - | 4 Weeks | Panel Mount | Carling Technologies | - | 1 | CARLING TECHNOLOGIES INC | Not Illuminated | Carling Technologies | CA3-B0-34-650-331-C | + 85 C | Carling Technologies | - 40 C | Panel | - | Bulk | Active | Active | 5.52 | - | - | - | 11.852051 oz | - | 125 VDC | 277VAC/480VAC | - | C | HYDRAULIC MAGNETIC | Circuit Breakers | 50A | compliant | 50(A) | Stud | CSA, UL | Handle | - | 3 | None | Magnetic (Hydraulic Delay) | - | MAGNETIC CIRCUIT BREAKER | - | Circuit Breakers | - | Circuit Breakers | 63.5 mm | 47 mm | 57.53 mm | ||
![]() AB2-B0-26-620-1D1-C Carling Technologies | 15 |
| - | - | Panel Mount | Carling Technologies | - | 1 | - | Not Illuminated | Carling Technologies | - | + 85 C | Carling Technologies | - 40 C | Panel | -40C to 85C | Bulk | - | Active | - | Details | - | - | 4.585615 oz | Industrial grade | 80 VDC | 277VAC/80VDC | - | A | Hydraulic-Magnetic | Circuit Breakers | 20A | - | 20(A) | Quick Connect | CSA, UL | Handle | - | 2 | None | Magnetic (Hydraulic Delay) | - | - | Industrial | Circuit Breakers | - | Circuit Breakers | 50.8 mm | 41.66 mm | 38.48 mm | ||
![]() DD2-B0-24-615-1G2-C Carling Technologies | 2131 |
| - | 4 Weeks | DIN Rail | Carling Technologies | - | 1 | CARLING TECHNOLOGIES INC | Not Illuminated | Carling Technologies | DD2-B0-24-615-1G2-C | + 85 C | Carling Technologies | - 40 C | Din-Rail | -40C to 85C | Bulk | Active | Active | 5.55 | Details | Yes | - | - | Industrial grade | 80 VDC | 277VAC/480VAC | - | D | HYDRAULIC MAGNETIC | Circuit Breakers | 15A | compliant | 15(A) | Screw | CSA, UL | Rocker | - | 2 | None | Magnetic (Hydraulic Delay) | Toggle Switches | MAGNETIC CIRCUIT BREAKER | Industrial | Circuit Breakers | - | Circuit Breakers | 91.75 mm | 49 mm | 38.48 mm | ||
![]() CA2-B0-14-675-622-C Carling Technologies | 2814 |
| - | - | Panel Mount | - | - | - | - | - | - | - | - | Carling Technologies | - | - | - | Bulk | - | Active | - | - | - | - | - | - | 150 V | - | - | C | - | - | 75A | - | - | - | CSA, UL | Lever | - | 2 | None | Magnetic (Hydraulic Delay) | - | - | - | - | - | - | - | - | - | ||
![]() C21-B0-14-810-31A-MG Carling Technologies | 7 |
| - | 4 Weeks | Panel Mount | Carling Technologies | - | 1 | CARLING TECHNOLOGIES INC | Not Illuminated | Carling Technologies | C21-B0-14-810-31A-MG | + 85 C | Carling Technologies | - 40 C | Panel Mount | - | Bulk | Active | Active | 1.94 | - | - | - | 4 oz | - | 80 V | - | - | C | Hydraulic-Magnetic | Circuit Breakers | 100A | compliant | - | Stud | CSA, UL489 | Rocker | - | 1 | None | Magnetic (Hydraulic Delay) | - | MAGNETIC CIRCUIT BREAKER | - | Circuit Breakers | UL489 Listed; CSA | Circuit Breakers | - | - | - | ||
![]() AF2-B0-26-620-231-D Carling Technologies | In Stock | - | - | 4 Weeks | Panel Mount | Carling Technologies | - | 1 | CARLING TECHNOLOGIES INC | Not Illuminated | Carling Technologies | AF2-B0-26-620-231-D | + 85 C | Carling Technologies | - 40 C | Panel | - | Bulk | Active | Active | 5.52 | Details | Yes | - | - | - | 80 VDC | 250VAC | - | A | HYDRAULIC MAGNETIC | Circuit Breakers | 20A | compliant | 20(A) | Screw | CSA, VDE, UL | Rocker | - | 2 | None | Magnetic (Hydraulic Delay) | Circuit Breaker | MAGNETIC CIRCUIT BREAKER | - | Circuit Breakers | - | Circuit Breakers | 50.8 mm | 41.66 mm | 18.92 mm | ||
![]() GA2-B0-24-663-11-DE Carling Technologies | 2689 |
| - | 8 Weeks | DIN Rail | Carling Technologies | - | 1 | CARLING TECHNOLOGIES INC | Not Illuminated | Carling Technologies | GA2-B0-24-663-11-DE | + 85 C | Carling Technologies | - 40 C | Panel | -40C to 85C | Bulk | Active | Active | 1.94 | - | - | - | - | Industrial grade | 80 VDC | 240VAC | - | G | HYDRAULIC MAGNETIC | Circuit Breakers | 63A | compliant | 63(A) | Screw | TUV, UL | Handle | - | 2 | None | Magnetic (Hydraulic Delay) | Magnetic Circuit Breaker | MAGNETIC CIRCUIT BREAKER | Industrial | Circuit Breakers | UL Recognized | Circuit Breakers | - | - | - | ||
![]() CT1-B2-14-450-A11-MF Carling Technologies | 36 |
| - | - | Panel Mount | Carling Technologies | - | 1 | - | Not Illuminated | Carling Technologies | - | + 85 C | Carling Technologies | - 40 C | Panel | - | Bulk | - | Active | - | - | - | - | 4 oz | - | 80 VDC | 277VAC/480VAC | - | C | HYDRAULIC MAGNETIC | Circuit Breakers | 5A | - | 5(A) | Stud | CSA, VDE, UL489 | Handle | - | 1 | None | Magnetic (Hydraulic Delay) | Toggle Switches | - | - | Circuit Breakers | - | Circuit Breakers | 63.5 mm | 47 mm | 19.18 mm |