- Actuator Type
- Number of Poles
- Series
- Voltage Rating DC
- Approval Agency
- Breaker Type
- Current Rating (Amps)
- Illumination
- Illumination Voltage (Nominal)
- Mfr
- Mounting Type
- Product Status
Attribute column
Manufacturer
Carling Technologies Circuit Breakers
Product | Inventory | Pricing(USD) | Quantity | Datasheet | RoHS | Factory Lead Time | Mount | Mounting Type | Package / Case | Surface Mount | Terminal Shape | Mounting Feature | Brand | Factory Pack QuantityFactory Pack Quantity | Ihs Manufacturer | Illuminated | Manufacturer | Manufacturer Part Number | Manufacturer Series | Maximum Operating Temperature | Mfr | Minimum Operating Temperature | Mounting Styles | Operating Temp Range | Operating Temperature-Max | Operating Temperature-Min | Package | Part Life Cycle Code | Product Status | Risk Rank | RoHS | Rohs Code | Unit Weight | Usage Level | Voltage Rating DC | Voltage, Rating | Packaging | Published | Series | Tolerance | Part Status | Moisture Sensitivity Level (MSL) | Termination | Type | Max Operating Temperature | Min Operating Temperature | Color | Additional Feature | Subcategory | Voltage - Rated DC | Current Rating (Amps) | Reach Compliance Code | Current Rating | Reference Standard | Termination Style | Voltage - Rated AC | Approval Agency | Body Length or Diameter | Body Breadth | Physical Dimension | Actuator Type | Insulation Resistance | Illumination Voltage (Nominal) | Environmental Characteristics | Number of Poles | Illumination | Breaker Type | Product Type | Rated Current | Circuit Protection Type | Screening Level | Blow Characteristic | Rated Breaking Capacity | Rated Voltage(AC) | Circuit Function | Product | Compliance | Product Category | Height | Length | Width | Thickness | Body Height | RoHS Status | Lead Free |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() CMBA-083-NNFNN-B-A Carling Technologies | 38 |
| - | - | - | Panel Mount | - | - | - | - | Carling Technologies | 50 | - | Not Illuminated | Carling Technologies | - | - | + 85 C | Carling Technologies | - 40 C | Plug-In | -10C to 60C | - | - | Bulk | - | Active | - | Non-Compliant | - | - | Commercial grade | 32 V | 125VAC/250VAC/32VDC | - | - | CMBA | - | - | - | - | Thermal | - | - | - | - | Circuit Breakers | - | 8A | - | 8(A) | - | Quick Connect | - | cUL,TUV, UL | - | - | - | Automatic Reset | - | - | - | 1 | None | Thermal | - | - | - | Commercial | - | - | - | - | Circuit Breakers | - | Circuit Breakers | - | - | - | - | - | - | - | ||
![]() FA1-B2-16-825-52A-BJ Carling Technologies | 2441 |
| - | 8 Weeks | - | Chassis Mount | - | - | - | - | Carling Technologies | 1 | CARLING TECHNOLOGIES INC | - | Carling Technologies | FA1-B2-16-825-52A-BJ | - | - | Carling Technologies | - | - | - | - | - | Bulk | Active | Active | 5.57 | - | - | - | - | 125 V | - | - | - | F | - | - | - | - | - | - | - | - | - | Circuit Breakers | - | 250A | compliant | - | - | - | - | cULus, TUV, UL489 | - | - | - | Lever | - | - | - | 1 | None | Magnetic (Hydraulic Delay) | - | - | MAGNETIC CIRCUIT BREAKER | - | - | - | - | - | - | - | Circuit Breakers | - | - | - | - | - | - | - | ||
![]() B11-B0-46-610-14A-K3 Carling Technologies | In Stock | - | - | 4 Weeks | - | Panel Mount | - | - | - | - | Carling Technologies | 1 | CARLING TECHNOLOGIES INC | - | Carling Technologies | B11-B0-46-610-14A-K3 | - | - | Carling Technologies | - | Panel | -40C to 85C | - | - | Bulk | Active | Active | 5.57 | - | - | - | Industrial grade | 80 V | 120VAC/240VAC | - | - | B | - | - | - | - | HYDRAULIC MAGNETIC | - | - | - | - | Circuit Breakers | - | 10A | compliant | 10(A) | - | Screw | - | TUV, UL489 | - | - | - | Rocker | - | - | - | 1 | None | Magnetic (Hydraulic Delay) | - | - | MAGNETIC CIRCUIT BREAKER | Industrial | - | - | - | - | - | - | Circuit Breakers | - | - | - | - | - | - | - | ||
![]() MU1-S-62-285-1-A21-B-C Carling Technologies | In Stock | - | - | - | - | Panel Mount | - | - | - | - | - | - | - | - | - | - | - | - | Carling Technologies | - | Panel | -40C to 85C | - | - | Bulk | - | Active | - | - | - | - | Industrial grade | 80 V | 250VAC | - | - | M | - | - | - | - | HYDRAULIC MAGNETIC | - | - | - | - | - | - | 850mA | - | - | - | Quick Connect | - | CSA, UL1077 | - | - | - | Push to Reset | - | - | - | 1 | None | Magnetic (Hydraulic Delay) | - | - | - | Industrial | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||
![]() MU1-B-24-630-2-A21-B-C Carling Technologies | 49 |
| - | - | - | Panel Mount | - | - | - | - | Carling Technologies | 1 | - | - | Carling Technologies | - | - | - | Carling Technologies | - | - | - | - | - | Bulk | - | Active | - | - | - | - | - | 80 V | - | - | - | M | - | - | - | - | - | - | - | - | - | Circuit Breakers | - | 30A | - | - | - | - | - | CSA, UL1077 | - | - | - | Push to Reset | - | - | - | 1 | None | Magnetic (Hydraulic Delay) | - | - | - | - | - | - | - | - | - | - | Circuit Breakers | - | - | - | - | - | - | - | ||
![]() CA3-X0-17-677-321-D Carling Technologies | In Stock | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | ||
![]() CA1-B0-24-610-311-D Carling Technologies | 5 |
| - | - | - | Panel Mount | - | NO | STUD | PANEL MOUNT | Carling Technologies | 1 | CARLING TECHNOLOGIES INC | Not Illuminated | Carling Technologies | CA1-B0-24-610-311-D | C | + 85 C | Carling Technologies | - 40 C | Panel Mount | - | 85 °C | -40 °C | Bulk | Active | Active | 5.57 | - | Yes | 4 oz | - | 150 VDC | 480 VAC, 150 VDC | - | - | C | - | - | - | - | Supplementary Protector / Motor Controller | - | - | - | ENVIRONMENTAL CHARACTERISTICS: ENVIRONMENT RESISTANT | Circuit Breakers | - | 10A | compliant | 10 A | CSA; UL; VDE | Stud | - | CSA, VDE, UL | 63.5 mm | 19.18 mm | 63.5mm x 19.18mm x 66.68mm | Handle | - | - | CORROSSION RESISTANT; MOISTURE RESISTANT | 1 Pole | None | Magnetic (Hydraulic Delay) | Hydraulic Magnetic Circuit Breakers | 10 A | MAGNETIC CIRCUIT BREAKER | - | MEDIUM | 5000 A | 480 V | SERIES TRIP | Circuit Breakers | - | Circuit Breakers | 63.5 mm | 47 mm | 19.18 mm | - | 66.68 mm | - | - | ||
![]() CLB-063-11A1B-B-A Carling Technologies | In Stock | - | - | - | - | Panel Mount | - | - | - | - | Carling Technologies | 50 | - | - | Carling Technologies | - | - | - | Carling Technologies | - | - | - | - | - | Bulk | - | Active | - | - | - | - | - | 32 V | - | - | - | * | - | - | - | - | - | - | - | - | - | Circuit Breakers | - | 6A | - | - | - | - | - | - | - | - | - | Push to Reset | - | - | - | 1 | None | Thermal | Thermal Circuit Breakers | - | - | - | - | - | - | - | - | - | Circuit Breakers | - | - | - | - | - | - | - | ||
![]() CC1-B0-14-420-21B-MF Carling Technologies | In Stock | - | - | 4 Weeks | - | Panel Mount | - | - | - | - | Carling Technologies | 1 | CARLING TECHNOLOGIES INC | Not Illuminated | Carling Technologies | CC1-B0-14-420-21B-MF | - | + 85 C | Carling Technologies | - 40 C | Panel Mount | - | - | - | Bulk | Active | Active | 1.9 | - | - | 4 oz | - | 80 VDC | 240 VAC, 80 VDC | - | - | C | - | - | - | - | Hydraulic-Magnetic | - | - | - | - | Circuit Breakers | - | 2A | compliant | 2 A | - | Screw | - | CSA, VDE, UL489 | - | - | - | Handle | - | - | - | 1 Pole | None | Magnetic (Hydraulic Delay) | - | - | MAGNETIC CIRCUIT BREAKER | - | - | - | - | - | Circuit Breakers | - | Circuit Breakers | 63.5 mm | 47 mm | 18.92 mm | - | - | - | - | ||
![]() EA2-B0-24-912-22A-CC Carling Technologies | In Stock | - | - | - | - | Panel Mount | - | - | - | - | Carling Technologies | 1 | CARLING TECHNOLOGIES INC | Not Illuminated | Carling Technologies | EA2-B0-24-912-22A-CC | - | + 85 C | Carling Technologies | - 40 C | Panel Mount | - | - | - | Bulk | Active | Active | 5.48 | Details | Yes | 1.111 lbs | - | 125 V | - | - | - | E | - | - | - | - | Hydraulic-Magnetic | - | - | - | - | Circuit Breakers | - | 125A | compliant | 125 A | - | Stud | - | CSA, UL489 | - | - | - | Handle | - | - | - | 2 Pole | None | Magnetic (Hydraulic Delay) | Branch Circuit Protection | - | MAGNETIC CIRCUIT BREAKER | - | - | - | - | - | Circuit Breakers | - | Circuit Breakers | - | - | - | - | - | - | - | ||
![]() CMB-153-27G3N-B-A Carling Technologies | 277 | - | - | 11 Weeks, 2 Days | - | Panel Mount | - | - | - | - | Carling Technologies | 50 | CARLING TECHNOLOGIES INC | Not Illuminated | Carling Technologies | CMB-153-27G3N-B-A | CMB | + 60 C | Carling Technologies | - 10 C | Panel Mount | - | - | - | Bulk | Active | Active | 2.08 | Details | Yes | 0.646043 oz | - | 32 VDC | 32 VDC, 250 VAC | - | - | CMB | - | - | - | - | Thermal | - | - | - | - | Circuit Breakers | - | 15A | compliant | 15A | - | Quick Connect | - | - | - | - | - | Reset Button | - | - | - | 1 Pole | None | Thermal | Thermal Circuit Breakers | - | THERMAL CIRCUIT BREAKER | - | - | - | - | - | Circuit Breakers | UL; cUL; CSA; TUV; CE; UL1500 Ignition Protected | Circuit Breakers | 45.2 mm | 29.3 mm | 14 mm | - | - | - | - | ||
![]() CLB-183-11BNN-W-A Carling Technologies | In Stock | - | - | - | - | Panel Mount | - | - | - | - | Carling Technologies | 50 | - | - | Carling Technologies | - | - | - | Carling Technologies | - | - | - | - | - | Bulk | - | Active | - | - | - | - | - | 32 V | - | - | - | CLB | - | - | - | - | - | - | - | - | - | Circuit Breakers | - | 18A | - | - | - | - | - | - | - | - | - | Push to Reset | - | - | - | 1 | None | Thermal | Thermal Circuit Breakers | - | - | - | - | - | - | - | - | - | Circuit Breakers | - | - | - | - | - | - | - | ||
![]() CTB-B-B-12 Carling Technologies | 117 |
| Datasheet | 10 Weeks | Chassis, Front, Panel | Panel Mount | 125 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Bulk | 2012 | CTB | 0.005% | Active | 1 (Unlimited) | Quick Connect | - | 60°C | -10°C | Black | - | - | 50V | - | - | 12A | - | - | 250V | CE, TUV, UL | - | - | - | Rocker | 100MOhm | - | - | 1 | - | Thermal | - | - | - | - | - | - | - | - | - | - | - | 39mm | 38.99mm | 13.71mm | 1.5748mm | - | ROHS3 Compliant | Lead Free | ||
![]() CTB-B-B-05 Carling Technologies | 687 |
| Datasheet | 10 Weeks | Chassis, Front, Panel | Panel Mount | 100 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Bulk | 2012 | CTB | 0.005% | Active | 1 (Unlimited) | Quick Connect | - | 60°C | -10°C | Black | - | - | 50V | - | - | 5A | - | - | 250V | CE, TUV, UL | - | - | - | Rocker | 100MOhm | - | - | 1 | - | Thermal | - | - | - | - | - | - | - | - | - | - | - | 39mm | 38.99mm | 13.71mm | 1.5748mm | - | ROHS3 Compliant | Contains Lead | ||
![]() CMB-043-27G5N-W-A Carling Technologies | 5 |
| - | 8 Weeks | - | Panel Mount | - | - | - | - | Carling Technologies | 50 | CARLING TECHNOLOGIES INC | Not Illuminated | Carling Technologies | CMB-043-27G5N-W-A | CMB | + 60 C | Carling Technologies | - 10 C | Panel Mount | - | - | - | Bulk | Active | Active | 5.57 | Details | Yes | - | - | 32 VDC | 250 VAC, 32 VDC | - | - | CMB | - | - | - | - | Thermal | - | - | - | - | Circuit Breakers | - | 4A | compliant | 4 A | - | Quick Connect | - | - | - | - | - | Reset Button | - | - | - | 1 Pole | None | Thermal | Thermal Circuit Breakers | - | THERMAL CIRCUIT BREAKER | - | - | - | - | - | Circuit Breakers | UL; cUL; CSA; TUV; CE; UL1500 Ignition Protected | Circuit Breakers | 29.3 mm | - | 14 mm | - | - | - | - | ||
![]() MS1-B-14-625-3-1BB-A-A Carling Technologies | 2606 |
| - | 4 Weeks | - | Panel Mount | - | - | - | - | Carling Technologies | 1 | CARLING TECHNOLOGIES INC | Not Illuminated | Carling Technologies | MS1-B-14-625-3-1BB-A-A | MS | + 85 C | Carling Technologies | - 40 C | Panel Mount | - | - | - | Bulk | Active | Active | 1.94 | Non-Compliant | - | - | - | 65 V | 50 VDC | - | - | M | - | - | - | - | Hydraulic-Magnetic | - | - | - | - | Circuit Breakers | - | 25A | compliant | 25 A | - | Screw | - | - | - | - | - | Toggle | - | - | - | 1 | None | Magnetic (Hydraulic Delay) | - | - | THERMAL MAGNETIC | - | - | - | - | - | Circuit Breakers | - | Circuit Breakers | - | - | - | - | - | - | - | ||
![]() MU1-B-34-615-1-A21-B-D Carling Technologies | 25 |
| - | - | - | Panel Mount | - | - | - | - | Carling Technologies | 1 | CARLING TECHNOLOGIES INC | Not Illuminated | Carling Technologies | MU1-B-34-615-1-A21-B-D | - | + 85 C | Carling Technologies | - 40 C | Panel | -40C to 85C | - | - | Bulk | Active | Active | 1.88 | - | - | 1.058219 oz | Industrial grade | 80 VDC | - | - | - | M | - | - | - | - | HYDRAULIC MAGNETIC | - | - | - | - | Circuit Breakers | - | 15A | compliant | 15(A) | - | Screw | - | CSA, UL, VDE | - | - | - | Reset Button | - | - | - | 1 | None | Magnetic (Hydraulic Delay) | Circuit Breaker | - | MAGNETIC CIRCUIT BREAKER | Industrial | - | - | - | - | Circuit Breakers | UL Recognized; CSA; VDE | Circuit Breakers | 34.93 mm | 37.69 mm | 17.27 mm | - | - | - | - | ||
![]() AM2-B0-14-470-201-C Carling Technologies | 2853 |
| - | - | - | Panel Mount | - | - | - | - | Carling Technologies | 1 | - | - | Carling Technologies | - | - | - | Carling Technologies | - | - | - | - | - | Bulk | - | Active | - | Details | - | - | - | 80 V | - | - | - | A | - | - | - | - | - | - | - | - | - | Circuit Breakers | - | 7A | - | - | - | - | - | CSA, UL | - | - | - | Toggle | - | - | - | 2 | None | Magnetic (Hydraulic Delay) | - | - | - | - | - | - | - | - | - | - | Circuit Breakers | - | - | - | - | - | - | - | ||
![]() BA1-B0-24-630-22C-KG Carling Technologies | 24 |
| - | - | - | Panel Mount | - | - | - | - | Carling Technologies | 1 | - | - | Carling Technologies | - | - | - | Carling Technologies | - | - | - | - | - | Bulk | - | Active | - | - | - | - | - | 80 V | - | - | - | B | - | - | - | - | - | - | - | - | - | Circuit Breakers | - | 30A | - | - | - | - | - | UL489 | - | - | - | Lever | - | - | - | 1 | None | Magnetic (Hydraulic Delay) | - | - | - | - | - | - | - | - | - | - | Circuit Breakers | - | - | - | - | - | - | - | ||
![]() CMBA-043-NNFNN-B-A Carling Technologies | 5 |
| - | - | - | Panel Mount | - | - | - | - | Carling Technologies | 50 | - | Not Illuminated | Carling Technologies | - | - | + 85 C | Carling Technologies | - 40 C | Panel Mount | - | - | - | Bulk | - | Active | - | Non-Compliant | - | - | - | 32 V | - | - | - | CMBA | - | - | - | - | Hydraulic-Magnetic | - | - | - | - | Circuit Breakers | - | 4A | - | - | - | - | - | cUL,TUV, UL | - | - | - | Automatic Reset | - | - | - | 1 | None | Thermal | - | - | - | - | - | - | - | - | Circuit Breakers | - | Circuit Breakers | - | - | - | - | - | - | - |