- Packing unit
- Products weight (without packaging)
- Environmental items
- Insulation Materials
- Number of potentials
- Pitch
- Pluggable or not
- Rated voltage(III/2)
- Ambient temperature (operation)
- Contact Materials
- Rated voltage (B)
- Rated current (B)
Attribute column
Manufacturer
DEGSON Terminal Blocks - Wire to Board
Product | Inventory | Pricing(USD) | Quantity | Datasheet | RoHS | Ambient temperature (operation) | AWG | Bridge | Coding strip | Conductor cross section flexible | Conductor cross section solid | Connectable conductor cross section | Connection direction | Contact Materials | Contact point metal surface | Contact zone metal surface | Environmental items | Insulating material group | Insulation Materials | marker strip | Marking strip | Number of potentials | Operating tool | Packing unit | Pin arrangement | Pluggable or not | Products weight (without packaging) | Rated current (B) | Rated current (C) | Rated current (D) | Rated power frequency voltage(1min) | Rated surge voltage(II/2) | Rated surge voltage(III/2) | Rated surge voltage(III/3) | Rated voltage (B) | Rated voltage (C) | Rated voltage (D) | Rated voltage(II/2) | Rated voltage(III/2) | Rated voltage(III/3) | Screwdriver | Shell color | Strip length | Test Specification | Type of installation | Wire take tool | Pitch | Process |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() DG141V-2.54-18P DEGSON | In Stock | - | Datasheet | -40℃~105℃(depending on derating curve) | 24~20AWG | / | / | 0.2~1.0mm² | 0.2~1.0mm² | - | 90° | Copper alloy | tin-plated | - | Compliant with REACH/RoHS | Ⅰ | PA66 | - | / | 18 | / | 400 | Double-row in a straight line | no | 9.28 | 2A | 2A | 2A | 1.25KV | - | - | - | 150V | 150V | 150V | - | 130V | - | / | - | 11mm | UL1059/IEC60998 | PCB welding | - | 2.54mm | Wave soldering/manual soldering | ||
![]() DG141V-2.54-23P DEGSON | In Stock | - | Datasheet | -40℃~105℃(depending on derating curve) | 24~20AWG | / | / | 0.2~1.0mm² | 0.2~1.0mm² | - | 90° | Copper alloy | tin-plated | - | Compliant with REACH/RoHS | Ⅰ | PA66 | - | / | 23 | / | 300 | Double-row in a straight line | no | 11.77 | 2A | 2A | 2A | 1.25KV | - | - | - | 150V | 150V | 150V | - | 130V | - | / | - | 11mm | UL1059/IEC60998 | PCB welding | - | 2.54mm | Wave soldering/manual soldering | ||
![]() DG141V-2.54-24P DEGSON | In Stock | - | Datasheet | -40℃~105℃(depending on derating curve) | 24~20AWG | / | / | 0.2~1.0mm² | 0.2~1.0mm² | - | 90° | Copper alloy | tin-plated | - | Compliant with REACH/RoHS | Ⅰ | PA66 | - | / | 24 | / | 300 | Double-row in a straight line | no | 12.26 | 2A | 2A | 2A | 1.25KV | - | - | - | 150V | 150V | 150V | - | 130V | - | / | - | 11mm | UL1059/IEC60998 | PCB welding | - | 2.54mm | Wave soldering/manual soldering | ||
![]() DG141V-2.54-27P DEGSON | In Stock | - | Datasheet | -40℃~105℃(depending on derating curve) | 24~20AWG | / | / | 0.2~1.0mm² | 0.2~1.0mm² | - | 90° | Copper alloy | tin-plated | - | Compliant with REACH/RoHS | Ⅰ | PA66 | - | / | 27 | / | 250 | Double-row in a straight line | no | 13.76 | 2A | 2A | 2A | 1.25KV | - | - | - | 150V | 150V | 150V | - | 130V | - | / | - | 11mm | UL1059/IEC60998 | PCB welding | - | 2.54mm | Wave soldering/manual soldering | ||
![]() DG141V-2.54-30P DEGSON | In Stock | - | Datasheet | -40℃~105℃(depending on derating curve) | 24~20AWG | / | / | 0.2~1.0mm² | 0.2~1.0mm² | - | 90° | Copper alloy | tin-plated | - | Compliant with REACH/RoHS | Ⅰ | PA66 | - | / | 30 | / | 220 | Double-row in a straight line | no | 15.25 | 2A | 2A | 2A | 1.25KV | - | - | - | 150V | 150V | 150V | - | 130V | - | / | - | 11mm | UL1059/IEC60998 | PCB welding | - | 2.54mm | Wave soldering/manual soldering | ||
![]() DG248H2-5.0-08P DEGSON | In Stock | - | Datasheet | -40℃~105℃(depending on derating curve) | 28~16AWG | - | - | 0.2~1.5mm² | 0.2~1.5mm² | - | 45° | Copper alloy | tin-plated | tin-plated | Compliant with REACH/RoHS | - | PA66 | - | - | 8 | - | 480 | Double-row in a straight line | no | 6.11 | 10A | - | 10A | - | 4KV | 4KV | 4KV | 300V | - | 300V | 630V | 320V | 320V | - | Black | 10mm | IEC60947/UL1059 | PCB welding | - | 5mm | Wave soldering/manual soldering | ||
![]() DG248H2-5.0-12P DEGSON | In Stock | - | Datasheet | -40℃~105℃(depending on derating curve) | 28~16AWG | - | - | 0.2~1.5mm² | 0.2~1.5mm² | - | 45° | Copper alloy | tin-plated | tin-plated | Compliant with REACH/RoHS | - | PA66 | - | - | 12 | - | 320 | Double-row in a straight line | no | 9.02 | 10A | - | 10A | - | 4KV | 4KV | 4KV | 300V | - | 300V | 630V | 320V | 320V | - | Black | 10mm | IEC60947/UL1059 | PCB welding | - | 5mm | Wave soldering/manual soldering | ||
![]() DG248H2-5.0-14P DEGSON | In Stock | - | Datasheet | -40℃~105℃(depending on derating curve) | 28~16AWG | - | - | 0.2~1.5mm² | 0.2~1.5mm² | - | 45° | Copper alloy | tin-plated | tin-plated | Compliant with REACH/RoHS | - | PA66 | - | - | 14 | - | 280 | Double-row in a straight line | no | 10.47 | 10A | - | 10A | - | 4KV | 4KV | 4KV | 300V | - | 300V | 630V | 320V | 320V | - | Black | 10mm | IEC60947/UL1059 | PCB welding | - | 5mm | Wave soldering/manual soldering | ||
![]() DG248H2-5.0-24P DEGSON | In Stock | - | Datasheet | -40℃~105℃(depending on derating curve) | 28~16AWG | - | - | 0.2~1.5mm² | 0.2~1.5mm² | - | 45° | Copper alloy | tin-plated | tin-plated | Compliant with REACH/RoHS | - | PA66 | - | - | 24 | - | 160 | Double-row in a straight line | no | 17.75 | 10A | - | 10A | - | 4KV | 4KV | 4KV | 300V | - | 300V | 630V | 320V | 320V | - | Black | 10mm | IEC60947/UL1059 | PCB welding | - | 5mm | Wave soldering/manual soldering | ||
![]() DG248H2-5.0-26P DEGSON | In Stock | - | Datasheet | -40℃~105℃(depending on derating curve) | 28~16AWG | - | - | 0.2~1.5mm² | 0.2~1.5mm² | - | 45° | Copper alloy | tin-plated | tin-plated | Compliant with REACH/RoHS | - | PA66 | - | - | 26 | - | 150 | Double-row in a straight line | no | 19.2 | 10A | - | 10A | - | 4KV | 4KV | 4KV | 300V | - | 300V | 630V | 320V | 320V | - | Black | 10mm | IEC60947/UL1059 | PCB welding | - | 5mm | Wave soldering/manual soldering | ||
![]() DG248H2-5.0-28P DEGSON | In Stock | - | Datasheet | -40℃~105℃(depending on derating curve) | 28~16AWG | - | - | 0.2~1.5mm² | 0.2~1.5mm² | - | 45° | Copper alloy | tin-plated | tin-plated | Compliant with REACH/RoHS | - | PA66 | - | - | 28 | - | 120 | Double-row in a straight line | no | 20.66 | 10A | - | 10A | - | 4KV | 4KV | 4KV | 300V | - | 300V | 630V | 320V | 320V | - | Black | 10mm | IEC60947/UL1059 | PCB welding | - | 5mm | Wave soldering/manual soldering | ||
![]() DG248H2-5.0-30P DEGSON | In Stock | - | Datasheet | -40℃~105℃(depending on derating curve) | 28~16AWG | - | - | 0.2~1.5mm² | 0.2~1.5mm² | - | 45° | Copper alloy | tin-plated | tin-plated | Compliant with REACH/RoHS | - | PA66 | - | - | 30 | - | 120 | Double-row in a straight line | no | 22.11 | 10A | - | 10A | - | 4KV | 4KV | 4KV | 300V | - | 300V | 630V | 320V | 320V | - | Black | 10mm | IEC60947/UL1059 | PCB welding | - | 5mm | Wave soldering/manual soldering | ||
![]() DG248H2-5.0-34P DEGSON | In Stock | - | Datasheet | -40℃~105℃(depending on derating curve) | 28~16AWG | - | - | 0.2~1.5mm² | 0.2~1.5mm² | - | 45° | Copper alloy | tin-plated | tin-plated | Compliant with REACH/RoHS | - | PA66 | - | - | 34 | - | 120 | Double-row in a straight line | no | 25.02 | 10A | - | 10A | - | 4KV | 4KV | 4KV | 300V | - | 300V | 630V | 320V | 320V | - | Black | 10mm | IEC60947/UL1059 | PCB welding | - | 5mm | Wave soldering/manual soldering | ||
![]() DG248H2-5.0-38P DEGSON | In Stock | - | Datasheet | -40℃~105℃(depending on derating curve) | 28~16AWG | - | - | 0.2~1.5mm² | 0.2~1.5mm² | - | 45° | Copper alloy | tin-plated | tin-plated | Compliant with REACH/RoHS | - | PA66 | - | - | 38 | - | 100 | Double-row in a straight line | no | 27.93 | 10A | - | 10A | - | 4KV | 4KV | 4KV | 300V | - | 300V | 630V | 320V | 320V | - | Black | 10mm | IEC60947/UL1059 | PCB welding | - | 5mm | Wave soldering/manual soldering | ||
![]() DG248H2-5.0-40P DEGSON | In Stock | - | Datasheet | -40℃~105℃(depending on derating curve) | 28~16AWG | - | - | 0.2~1.5mm² | 0.2~1.5mm² | - | 45° | Copper alloy | tin-plated | tin-plated | Compliant with REACH/RoHS | - | PA66 | - | - | 40 | - | 100 | Double-row in a straight line | no | 29.39 | 10A | - | 10A | - | 4KV | 4KV | 4KV | 300V | - | 300V | 630V | 320V | 320V | - | Black | 10mm | IEC60947/UL1059 | PCB welding | - | 5mm | Wave soldering/manual soldering | ||
![]() DG248H2-5.0-44P DEGSON | In Stock | - | Datasheet | -40℃~105℃(depending on derating curve) | 28~16AWG | - | - | 0.2~1.5mm² | 0.2~1.5mm² | - | 45° | Copper alloy | tin-plated | tin-plated | Compliant with REACH/RoHS | - | PA66 | - | - | 44 | - | 80 | Double-row in a straight line | no | 32.3 | 10A | - | 10A | - | 4KV | 4KV | 4KV | 300V | - | 300V | 630V | 320V | 320V | - | Black | 10mm | IEC60947/UL1059 | PCB welding | - | 5mm | Wave soldering/manual soldering | ||
![]() DG248H2-5.0-46P DEGSON | In Stock | - | Datasheet | -40℃~105℃(depending on derating curve) | 28~16AWG | - | - | 0.2~1.5mm² | 0.2~1.5mm² | - | 45° | Copper alloy | tin-plated | tin-plated | Compliant with REACH/RoHS | - | PA66 | - | - | 46 | - | 80 | Double-row in a straight line | no | 33.75 | 10A | - | 10A | - | 4KV | 4KV | 4KV | 300V | - | 300V | 630V | 320V | 320V | - | Black | 10mm | IEC60947/UL1059 | PCB welding | - | 5mm | Wave soldering/manual soldering | ||
![]() DG248H2-5.0-48P DEGSON | In Stock | - | Datasheet | -40℃~105℃(depending on derating curve) | 28~16AWG | - | - | 0.2~1.5mm² | 0.2~1.5mm² | - | 45° | Copper alloy | tin-plated | tin-plated | Compliant with REACH/RoHS | - | PA66 | - | - | 48 | - | 80 | Double-row in a straight line | no | 35.21 | 10A | - | 10A | - | 4KV | 4KV | 4KV | 300V | - | 300V | 630V | 320V | 320V | - | Black | 10mm | IEC60947/UL1059 | PCB welding | - | 5mm | Wave soldering/manual soldering | ||
![]() DG271V-15.0-05P DEGSON | In Stock | - | Datasheet | -40℃~105℃(depending on derating curve) | - | / | / | 1.5~35mm² | 1.5~35mm² | 14~2AWG | 90° | copper | tin-plated | tin-plated | Compliant with REACH/RoHS | Ⅰ | PA66 | / | - | 5 | - | 30 | Double-row in a straight line | no | 126.2 | 101A | 101A | 5A | - | 6KV | 8KV | 8KV | 600V | 600V | 600V | 1000V | 1000V | 1000V | - | green | 24mm | IEC60947/UL1059 | PCB welding | / | 15mm | Wave soldering/manual soldering | ||
![]() DG271V-15.0-06P DEGSON | In Stock | - | Datasheet | -40℃~105℃(depending on derating curve) | - | / | / | 1.5~35mm² | 1.5~35mm² | 14~2AWG | 90° | copper | tin-plated | tin-plated | Compliant with REACH/RoHS | Ⅰ | PA66 | / | - | 6 | - | 25 | Double-row in a straight line | no | 151 | 101A | 101A | 5A | - | 6KV | 8KV | 8KV | 600V | 600V | 600V | 1000V | 1000V | 1000V | - | green | 24mm | IEC60947/UL1059 | PCB welding | / | 15mm | Wave soldering/manual soldering |