- Series
- Current Rating
- Number of Poles
- Actuator Type
- Product
- Type
- Voltage Rating DC
- Maximum Operating Temperature
- Minimum Operating Temperature
- Illuminated
- Factory Pack QuantityFactory Pack Quantity
- RoHS
Attribute column
Manufacturer
Weidmuller Circuit Breakers
Product | Inventory | Pricing(USD) | Quantity | Datasheet | RoHS | Factory Lead Time | Mount | Mounting Type | Terminal Shape | Operating Temperature (Max.) | Operating Temperature (Min.) | Usage Level | Published | Series | Part Status | Moisture Sensitivity Level (MSL) | Voltage - Rated DC | Current Rating (Amps) | Current Rating | Reference Standard | Voltage - Rated AC | Approval Agency | Actuator Type | Number of Poles | Illumination | Breaker Type | Circuit Protection Type | Load Current | Time to Trip | Rated Breaking Capacity | Circuit Function | Body Height | Radiation Hardening | REACH SVHC | RoHS Status | Lead Free |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() 9926251000 Weidmüller | In Stock | - | Datasheet | 10 Weeks | DIN Rail | DIN Rail | - | - | - | Commercial grade | 2007 | 9926 | Active | Not Applicable | - | - | 500mA | - | 120V | CE, CSA C22.2 No 235, UL1077, VDE | Lever | 1 | - | Magnetic (Hydraulic Delay) | MAGNETIC CIRCUIT BREAKER | - | 28 s | - | - | - | No | Unknown | RoHS Compliant | - | ||
![]() 6720005312 Weidmüller | In Stock | - | Datasheet | 12 Weeks | DIN Rail | DIN Rail | - | - | - | Commercial grade | 2012 | ESX10-T | Active | 1 (Unlimited) | 24V | - | 12A | - | - | ATEX, CE, CSA C22.2 No 14, CSA C22.2 No 142, CSA C22.2 No 213, UL1604, UL508, UL2367, VDE | Slide Switch | 1 | - | Thermal | - | 12A | 3 s | - | - | - | - | Unknown | RoHS Compliant | - | ||
![]() 9926251860 Weidmüller | In Stock | - | Datasheet | 9 Weeks | DIN Rail | DIN Rail | - | - | - | Commercial grade | 2009 | 9926 | Active | - | 125V | - | 60A | - | - | CE, CSA C22.2 No 235, UL1077, VDE | Lever | 1 | - | Magnetic (Hydraulic Delay) | - | - | - | - | - | - | - | - | RoHS Compliant | - | ||
![]() 926252005 Weidmüller | In Stock | - | - | - | DIN Rail | DIN Rail | SNAP ON | 65°C | -40°C | - | - | 9926 | Obsolete | 1 (Unlimited) | - | - | 5A | CE; CSA; UL; VDE | 240V | CE, CSA C22.2 No 235, UL1077, VDE | Lever | 2 | - | Magnetic (Hydraulic Delay) | MAGNETIC CIRCUIT BREAKER | - | - | 10000 A | TRIP | 69.8mm | - | - | Non-RoHS Compliant | - | ||
![]() 1279030000 Weidmüller | 26 |
| Datasheet | 6 Weeks | - | Holder | - | - | - | - | 2012 | 1180 | Active | 1 (Unlimited) | 72V | - | 5A | - | 250V | CSA C22.2 No 235, UL1077, VDE | Push-Push | 1 | - | Thermal | - | - | - | - | - | - | - | - | RoHS Compliant | - | ||
![]() BR1C6AC Weidmüller | In Stock | - | - | 7 Weeks | - | - | - | - | - | - | - | - | Obsolete | 1 (Unlimited) | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | RoHS Compliant | - | ||
![]() SU1C40UC Weidmüller | In Stock | - | Datasheet | 19 Weeks | - | DIN Rail | - | - | - | - | 2017 | SUxxxUC | Active | 1 (Unlimited) | 60V | 40A | - | - | 277V | CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL1077, VDE | Lever | 1 | None | Thermal Magnetic | - | - | - | - | - | - | - | - | RoHS Compliant | - | ||
![]() 9911100005 Weidmüller | In Stock | - | Datasheet | 12 Weeks | DIN Rail | DIN Rail | - | - | - | - | 2007 | CB2200 | Active | - | 65V | - | 1A | - | 480V | CSA C22.2 No 235, UL1077, VDE | Lever | 1 | - | Thermal Magnetic | - | - | - | - | - | - | No | Unknown | RoHS Compliant | Lead Free | ||
![]() BR2C20AC Weidmüller | In Stock | - | Datasheet | 7 Weeks | - | - | - | - | - | - | - | - | Obsolete | 1 (Unlimited) | - | - | - | - | - | - | - | - | - | - | THERMAL MAGNETIC | - | - | - | - | - | - | - | RoHS Compliant | - | ||
![]() BR2C5AC Weidmüller | In Stock | - | Datasheet | 7 Weeks | - | - | - | - | - | - | - | - | Obsolete | 1 (Unlimited) | - | - | - | - | - | - | - | - | - | - | THERMAL MAGNETIC | - | - | - | - | - | - | - | RoHS Compliant | - | ||
![]() BR2C40AC Weidmüller | In Stock | - | - | 7 Weeks | - | - | - | - | - | - | - | - | Obsolete | 1 (Unlimited) | - | - | - | - | - | - | - | - | - | - | THERMAL MAGNETIC | - | - | - | - | - | - | - | RoHS Compliant | - | ||
![]() BR2C25AC Weidmüller | In Stock | - | - | 7 Weeks | - | - | - | - | - | - | - | - | Obsolete | 1 (Unlimited) | - | - | - | - | - | - | - | - | - | - | THERMAL MAGNETIC | - | - | - | - | - | - | - | RoHS Compliant | - | ||
![]() 1278730000 Weidmüller | In Stock | - | Datasheet | 8 Weeks | - | Holder | - | - | - | - | - | - | Active | 1 (Unlimited) | 28V | - | 3A | - | - | CSA C22.2 No 235, UL1077, VDE | Push to Reset | 1 | - | Thermal | - | - | - | - | - | - | - | - | RoHS Compliant | - | ||
![]() 1278820000 Weidmüller | In Stock | - | Datasheet | 8 Weeks | - | Holder | - | - | - | - | - | - | Active | 1 (Unlimited) | 28V | - | 20A | - | - | CSA C22.2 No 235, UL1077, VDE | Push to Reset | 1 | - | Thermal | - | - | - | - | - | - | - | - | RoHS Compliant | - | ||
![]() BR2C5UC Weidmüller | In Stock | - | Datasheet | 19 Weeks | - | DIN Rail | - | - | - | - | 2017 | BRxxxUC | Active | 1 (Unlimited) | 125V | 5A | - | - | 480V | CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE | Lever | 2 | None | Thermal Magnetic | - | - | - | - | - | - | - | - | RoHS Compliant | - | ||
![]() 9926252510 Weidmüller | In Stock | - | Datasheet | 16 Weeks | DIN Rail | DIN Rail | - | - | - | Commercial grade | 2007 | 9926 | Active | Not Applicable | - | - | 10A | - | 480V | CE, CSA C22.2 No 235, UL1077, VDE | Lever | 2 | - | Magnetic (Hydraulic Delay) | MAGNETIC CIRCUIT BREAKER | - | 40 s | - | - | - | No | No SVHC | RoHS Compliant | - | ||
![]() 9926291120 Weidmüller | In Stock | - | Datasheet | 16 Weeks | DIN Rail | DIN Rail | - | - | - | - | 2007 | 9926 | Active | Not Applicable | - | - | 20A | - | 240V | CE, CSA C22.2 No 235, UL1077, VDE | Lever | 1 | - | Magnetic (Hydraulic Delay) | EQUIPMENT LEAKAGE CIRCUIT BREAKER | - | 40 s | - | - | - | - | - | RoHS Compliant | - | ||
![]() 9925680000 Weidmüller | In Stock | - | Datasheet | - | DIN Rail | DIN Rail | - | - | - | - | 2013 | CB9100 | Obsolete | Not Applicable | 110V | - | 2A | - | 480V | - | Lever | 2 | - | Thermal Magnetic | - | - | - | - | - | - | No | - | RoHS Compliant | - | ||
![]() 9925700000 Weidmüller | In Stock | - | Datasheet | 10 Weeks | DIN Rail | DIN Rail | - | - | - | - | 2009 | CB9100 | Obsolete | Not Applicable | 110V | - | 4A | - | 480V | - | Lever | 2 | - | Thermal Magnetic | - | - | - | - | - | - | No | - | RoHS Compliant | - | ||
![]() BR3D1AC Weidmüller | In Stock | - | - | 7 Weeks | - | - | - | - | - | - | - | - | Obsolete | 1 (Unlimited) | - | - | - | - | - | - | - | - | - | - | THERMAL MAGNETIC | - | - | - | - | - | - | - | RoHS Compliant | - |